SYMPTOM:
With USB enabled, certain tests will intermittently lock the system when USB legacy keyboard and mouse are enabled.

The tests that cause problems include: Utility - Read scan & the CPU tests.

PROBLEM ISOLATION AIDS:
- The system is a Netfinity 7000 M10 server, Type 8680, all models.

- A USB Keyboard is connected to the server.

- The system locks while running CPU Test of the System Diagnostics.

- The system locks while running Utility - Read scan of the System Diagnostics.

FIX:
No permanent fix available.

WORKAROUND:
Before running diagnostics, it is necessary to disconnect the mouse from the system.

DETAILS:
The use of a mouse while running diagnostics with a USB keyboard is not supported.

SAS KEYWORDS: