4.570 bytes |
Preloaded Software Information |
Document ID: DDSE-3TQM36 |
PC Server 325 / 330 - Installing Windows NT 3.51 to run multiprocessor mode
Applicable to: World-Wide
This tip pertains to the following IBM PC Servers:
IBM PC Server 325 type 8639 model PT0, PTW, PB0, RB0
-- or --
IBM PC Server 330 type 8640 model PT0, PB0, PM0
Use the following procedure to install Windows NT 3.51 running "Multiprocessor mode" on a PC Server 325 or 330.
IMPORTANT: Ensure that only one processor is installed in the server.
1. Download the 325/330 Utility Diskette from the IBM Website. The description is: "PC Server 325 (8639-PT0, PTW, PB0, RB0 / 330 (8640-PT0, PB0, PM0) Utility Diskette". The file image is a self-extracting file that will create a floppy diskette. Copy the contents of the diskette to a new directory of your choice on the hard drive.
2. Install Windows NT 3.51 running "Standard PC" mode (not as a Uniprocessor or Multiprocessor PC) on the server (see the ADDCPU.TXT on the 325/330 utility diskette for details).
NOTE : This utility is not required for the Japanese version of NT3.51 as this will install correctly as a Multiprocessor PC.
3. NT3.51 Service pack 5 (SP5) must be obtained.
Download SP5 from the Microsoft Website (the filename on the Website is SP5_351I.EXE), copy the file to a new directory of your choice (not the same directory as the 325/330 utility) on the server hard drive, expand the file using the following syntax from a command prompt:
SP5_351I.EXE -d
SP5 may be installed before or after running ADDCPU but UPDATE.EXE of the service pack must always be run after running ADDCPU.
NOTE: Both SP5 and the 325/330 utility directories contain a addcpu.exe file. Always use the addcpu.exe located in the directory containing the 325/330 utility files.
NOTE: There are two variations to complete the upgrade to multiprocessor mode operation. Only apply the contents of step 4 or step 5.
4. Without SP5 already installed :
A- The server machine currently has NT 3.51 Server installed w/one processor.
B- Plug in the second processor.
C- Run addcpu.exe from the 325/330 utility. Do not reboot.
D- Run 'update.exe' from SP5
E- Reboot
The NT blue screen will identify 2 system processors as well as the Multiprocessor Kernel.
------------------------------- OR ---------------------------
5. With SP5 already installed :
A- The server machine currently has NT 3.51 SP5 installed w/one processor.
B- Plug in the second processor.
C- Run addcpu.exe from the 325/330 utility. Do not reboot.
D- Run 'update.exe' from SP5
E- Reboot
The NT blue screen will identify 2 system processors as well as the Multiprocessor Kernel.
Windows NT is a trademark of Microsoft Corporation
SAS Keywords:
PSY2, NT 3.51, WINDOWS NT, UNCLASSIFIED, MICROSOFT, SP5, SERVICE PACK 5, MULTIPROCESSOR, SMP, 325, 330, D/T8639, D/T8640, 3.51, 325/330 UTILITY, SP5_351I.EXE, ADDCPU.EXE, UNIPROCESSOR
Software Product:
Version:
Vendor:
EDOC Number:
Announce Date:
GA Date:
Service End Date:
Program Services:
Search Keywords |
| |
Document Category |
Windows NT | |
Date Created |
20-04-98 | |
Last Updated |
03-12-98 | |
Revision Date |
02-12-99 | |
Brand |
IBM PC Server | |
Product Family |
PC Server 325, PC Server 330 | |
Machine Type |
8639, 8640 | |
Model |
PT0; PTW; PB0; RB0; PT0; PB0; PM0; 11Y; 1RY | |
TypeModel |
| |
Retain Tip (if applicable) |
H161539 | |
Reverse Doclinks |
Owning B.U.: USA, USA=A, EMA=N, AFE=A |