6.312 bytes

Service Hints & Tips

Document ID: MCGN-3XGFPW

Servers - Multiple DDD drives caused by incorrect channel mapping

Applicable to: Canada, United States

Symptom
After one drive becomes DDD, one or more other drives will appear to be in a DDD drive state.

Problem Isolation Aids
All of the following must be true for this TIP to apply:

The System is any model PC Server Type 8640, 8641, 8642, 8650, 8651, that supports and is configured with a Type II or a Type III Hot Swap backplane(s) AND / OR has a attached external enclosure Type 3518.

The System is configured one of the following Adapters / Controllers that supports the internal Hot-swap Bays and / or external enclosure(s) listed above:

Option P/N

FRU

ServeRAID Adapter

70G8489

06H9334

ServeRAID Adapter

70G8489

76H6875

ServeRAID II Adapter

76H3584

76H3587

ServeRAID II Onboard Controller

Integrated

Integrated


System Diagnostics pass.

ServeRAID / ServeRAID II diagnostics pass.

Fix
Note: all further references to "Bank" or "Banks" represents those internal to the System and / or those located in a System-connected External Enclosure.

Ensure the Channel-bank mapping correctly reflects the SCSI cabling of the ServeRAID / ServeRAID II Adapter / Controller to the Hot-Swap backplane(s) as follows:

1. Examine and NOTE the actual SCSI cabling of the ServeRAID / ServeRAID II Adapter / Controller to the internal Hot-Swap backplane(s) internal to the System and / or in the System-connected External Enclosure.

Example
Ch1 on the ServeRAID goes to Bank E
Ch2 on the ServeRAID goes to Bank D
Ch3 on the ServeRAID goes to Bank C

2. Ensure the ServeRAID / ServeRAID II Adapter / Controller is configured to map the SCSI Channels (the same as the physical cabling) using the following procedure:

Boot the System to the IBM ServeRAID and ServeRAID II diskette

Choose option 7 Advance Functions

Choose option 8 "Display/Change Adapter Params"

Choose option 5 "Set Channel -> Bank Mapping"

Using the same example (as in step 1), the Channel-Bank mapping should be set as follows:

CHANNEL - > BANK MAPPING

LOW ID HIGH ID LOW (REVERSE) HI (REVERSE)

CH 1

:E

CH 2

:D

CH 3

:C


Ensure the Channel-Bank Mapping reflects the actual physical SCSI cabling (as was NOTED in step 1).

SAS KEYWORDS:
PSY2, D/T8640, D/T8641, D/T8642, UNCLASSIFIED, SERVERAID, SERVERAID II, CHANNEL, BANK, MAPPING, D/T8650, D/T8651, DDD, MULTIPLE, H093980

Search Keywords

Hint Category

Hard Drives, RAID, Retain

Date Created

18-08-98

Last Updated

11-02-99

Revision Date

11-02-2000

Brand

IBM PC Server

Product Family

Netfinity 7000, PC Server 320, PC Server 330, PC Server 704, PC Server 720, Rack/Storage Enclosures, ServeRAID

Machine Type

8651, 8640, 8650, 8642, 3518, 8641, 8644, Various

Model

Various

TypeModel

Retain Tip (if applicable)

H093980

Reverse Doclinks
and Admin Purposes

Date last altered: A98/08/07