3.205 bytes |
Service Hints & Tips |
Document ID: GSMH-3BNJDB |
TP 701C/CS - Undetermined Problems
Applicable to: World-Wide
Undetermined Problems:
Perform the following procedures to isolate the failing FRU if the diagnostics tests did not identify which adapter or device failed, or whether the installed devices are incorrect, a short circuit is suspected, or the system is inoperative.
Note:
Do not replace a nondefective FRU.
Before performing these procedures, perform the following actions:
- Verify that all attached devices are supported by the computer.
- Verify that the power supply being used at the time of the failure is operating correctly. (See 'Power Systems Checkout—.)
1. Power-off the computer.
2. Check the cables, wires, and connectors for short circuits and open circuits. Visually check them for damage. If any problems are found, replace the FRU.
3. Remove or disconnect all of the following devices:
a. Non-IBM devices
b. Devices attached to the expansion bus connector
c. Printer, mouse, and other external devices
d. Battery pack
e. Hard disk drive
f. Diskette drive or the device attached to the diskette drive connector
g. SO-DIMM card
h. PCMCIA cards
Note:
Remember that removing the hard disk drive, a SO-DIMM card, or any adapter or device will cause configuration errors. Error code 162 will occur.
4. Power-on the computer.
5. Determine whether the problem has changed.
6. If the problem does not occur again, reconnect the removed devices one at a time until you find the failing FRU.
7. If the problem remains, replace the following FRUs one at a time.
Note:
Do not replace a nondefective FRU.
- Inverter Card.
- LCD Assembly.
- Top System Board.
- Bottom System Board.
Search Keywords |
| |
Hint Category |
Hardware Maintenance Information | |
Date Created |
22-11-96 | |
Last Updated |
19-08-98 | |
Revision Date |
18-08-99 | |
Brand |
IBM ThinkPad | |
Product Family |
ThinkPad 701 | |
Machine Type |
2630 | |
Model |
Various | |
TypeModel |
| |
Retain Tip (if applicable) |
N/A | |
Reverse Doclinks |