2.268 bytes

Service Hints & Tips

Document ID: MCGN-3SXR7G

Netfinity 7000 - Cooling failure light blinks slowly

Applicable to: World-Wide

SYMPTOM:
The system cooling failure light (amber light located at the front Control Panel) blinks slowly.

PROBLEM ISOLATION AIDS:
All of the following must be true for this tip to apply:

- The system is a IBM Netfinity 7000 type 8651 model RM0, TM0, RH0, TH0.

- All cooling fans are operate properly.

- All power supplies are operating properly.

- The fan jumpers (Fan3:J2J3, Fan4:J2J4 located near the left front edge of the Planar / Fan2:J5G2, Fan1:J5G1 located near right front edge of the Planar) are securely in place.

- All internal cables are secure.

- System diagnostics pass.

FIX:
Replace the Power Backplane Cover with FRU p/n12J3266 using normal warranty parts replacement procedures.

NOTE:
Refer to the "Power Backplane Removal" section of the "Hardware Maintenance Manual Supplement" publication
S06J-0791-00 p/n 06J0791 for power backplane cover removal and installation instructions.

SAS KEYWORDS:
PSY2, D/T8651, UNCLASSIFIED, COOLING FAILURE, PSY2PART, P/N12J3266

Search Keywords

PSY2, D/T8651, UNCLASSIFIED, COOLING FAILURE, PSY2PART, P/N12J3266

Hint Category

Retain

Date Created

26-03-98

Last Updated

14-07-98

Revision Date

13-07-99

Brand

IBM PC Server

Product Family

Netfinity 7000

Machine Type

8651

Model

RM0; TM0; RH0; TH0

TypeModel

Retain Tip (if applicable)

H163045

Reverse Doclinks
and Admin Purposes

USA=A, EMA=A, AFE=A, Owning B.U.: USA, Date last altered: A98/03/17