7.818 bytes

Product Information

Document ID: DDSE-42ZHZW

Netfinity 5500 - Diagnostic Error Codes

Applicable to: World-Wide

Diagnostic Error Codes
In the following error codes, X can be any number or letter.

Error Code/Symptom

FRU/Action

001-XXX-001
(Failed core tests)

1. System Board

005-XXX-001
(Failed Video test)

1. System Board
2. Processor Board

011-XXX-001
(Failed Serial Port test)

1. System Board

014-XXX-001
(Failed Parallel Port test)

1. System Board

015-XXX-001
Failed USB test)

1. System Board

020-XXX-001
(Failed PCI Interface test)

1. Processor Board
2. System Board

020-XXX-001
(Failed Hot Swap PCI Latch test)

1. Latch on PCI Hot plug Slot 1

020-XXX-002
(Failed Hot Swap PCI Latch test)

1. Latch on PCI Hot Plug Slot #2

020-XXX-003
(Failed Hot Swap PCI Latch test)

1. Latch on PCI Hot Plug Slot #3

020-XXX-004
(Failed Hot Swap PCI Latch test)

1. Latch on PCI Hot Plug Slot #4

030-XXX-001
(Failed Internal SCSI interface test)

1. System Board

035-XXX-001
(Failed RAID test for Fixed Disk in bay 1, SCSI ID 0)

1. Fixed Disk 1

035-XXX-002
(Failed RAID test for Fixed Disk in bay 2 SCSI ID 1

1. Fixed Disk 2

035-XXX-003
(Failed RAID test for Fixed Disk in bay 3, SCSI ID 2)

1. Fixed Disk 3

035-XXX-004
(Failed RAID test for Fixed Disk in bay 4, SCSI ID 3)

1. Fixed Disk 4

035-XXX-005
(Failed RAID test for Fixed Disk in bay 5, SCSI ID 4)

1. Fixed Disk 5

035-XXX-006
(Failed RAID test for Fixed Disk in bay 6, SCSI ID 5)

1. Fixed Disk 6

035-XXX-007
(Failed System Board RAID test)

1. System Board

035-XXX-006
(System Board RAID indicates POST error)

1. System Board

075-XXX-001
(Failed Power Supply test)

1. Power Supply

089-XXX-001
(Failed Microprocessor test)

1. Microprocessor

089-XXX-002
(Failed Optional Microprocessor test)

1. Optional Microprocessor

165-XXX-001
(Failed System Board test)

1. System Board
2. Processor Board
3. Power Backplane
4. Hot-Swap Drive Backplane

175-XXX-001
(Failed Fan 1 test)

1. Fan 1

175-XXX-002
(Failed Fan 2 test)

1. Fan 2

175-XXX-003
(Failed Fan 2 test)

1. Fan 3

175-XXX-004
(Processor Board Temperature sensor out of range)

1. Check system cooling

180-XXX-001
(Failed Information Panel LED test)

1. Information LED Panel

180-XXX-002
(Failed Diagnostics LED Panel test)

1. Diagnostics LED Panel

180-XXX-003
(Failed System Board LED test)

1. System Board

180-XXX-004
(Failed Processor Board LED test)

1. Processor Board

180-XXX-005
(Failed Hot Swap SCSI Backplane LED test)

1. Hot Swap SCSI Backplane

201-XXX-001
(Failed Memory test, see "Memory Settings")

1. DIMM Location J1

201-XXX-002
(Failed Memory test, see "Memory Settings")

1. DIMM Location J2

201-XXX-003
(Failed Memory test, see "Memory Settings")

1. DIMM Location J3

201-XXX-004
(Failed Memory test, see "Memory Settings")

1. DIMM Location J4

202-XXX-001
(Failed System Cache test)

1. Microprocessor

202-XXX-002
(Failed System Cache test on Optional Microprocessor)

1. Optional Microprocessor

206-XXX-001
(Failed Diskette Drive test)

1. Diskette Drive cable
2. Diskette Drive

215-XXX-001
(Failed IDE test)

1. System Board

217-XXX-001
(Failed BIOS Fixed Disk test)

1. Fixed Disk 1

217-XXX-002
(Failed BIOS Fixed Disk test)

1. Fixed Disk 2

217-XXX-003
(Failed BIOS Fixed Disk test)

1. Fixed Disk 3

217-XXX-004
(Failed BIOS Fixed Disk test)

1. Fixed Disk 4

217-XXX-005
(Failed BIOS Fixed Disk test)

1. Fixed Disk 5

217-XXX-006
(Failed BIOS Fixed Disk test)

1. Fixed Disk 6

301-XXX-001
(Failed Keyboard test)

1. Keyboard

405-XXX-001
(Failed Ethernet test)

1. System Board