3.287 bytes

Service Hints & Tips

Document ID: RMIE-3JDDFA

IBM PC330/PC350 - Video corruption of icons in QAPlus/Win-Win

Applicable to: World-Wide

Problem :
IBM PC 300 Series 6577 and 6587 preloaded with Windows 95 may exhibit video corruption of the icons within the QAPlus/WIN-WIN application if the video resolution is higher than 640x480x256.

Problem Isolation Aids :
When QAPlus/WIN-WIN is opened to the Hardware and DOS Configuration screens and the Windows Environment Resources screen, the icons across the top of the screen will not have a bitmap applied (no picture).
When the cursor is moved over the icons, the text descriptions at the bottom of the screen will indicate the function of the
action buttons. The information produced by each button is not affected by this problem.

Solution :
The user may use the text descriptions at the bottom of the screen to select the appropriate action button or change the
video resolution to 640x480x256 or lower.

QAPlus/WIN-WIN, included in the systems preloaded software, is being updated to eliminate this failure.

Software :
To obtain a copy of this Diskette, DoubleClick here :-


SAS KEYWORDS :
PSY2 D/T65XX 6577 6587
IBMPC PSVP PSVPDISP PSY2DISP
D/T6587 PC 350 PC350 PC300
PC 330 PC330 43090 PSVPPROG
PSY2PROG