3.053 bytes

Service Hints & Tips

Document ID: DSET-3EL5UC

This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose.

Aptiva - Problem resolution procedure for system unit that will not power on

Applicable to: World-Wide

Symptom:
System unit will not power on.
System unit will power on or off by itself when not programmed to.
System unit will not power off.

Resolution steps:
Return the system to its original hardware configuration before performing the following steps. Test the machine between each step:

1. Reseat the power switch. Reseat the planar power cables. Unplug the wakeup on ring cable. (Either end.)
2. If the symptoms disappear, replace the wake up on ring cable with a new cable and test again. If the symptoms do not disappear, skip to step 5.
3. If the failure reappears, replace the modem.
4. If the failure continues, replace the planar board.
5. Replace the power switch.
6. If the failure continues, replace the planar board.
7. If replacing the planar board in steps 4 or 6 does not alleviate the symptom, replace the power supply.

Search Keywords

Hint Category

Power, Diagnostics

Date Created

24-02-97

Last Updated

17-02-99

Revision Date

16-02-2000

Brand

IBM Aptiva

Product Family

Aptiva

Machine Type

2134, 2144, 2159, 2161, 2162, 2168, 2176

Model

All

TypeModel

Retain Tip (if applicable)

Reverse Doclinks