Technical Characteristics:

LCD Size and Type

15.0-in TFT

Viewable Image Size (in/mm)

15.0 / 381

Max Viewable Area (mm)

304.1 x 228.1

Luminance (@ 100 Hrs )

200 cd/m2

Contrast

150:01:00

Colors (6 Bit Drivers + Dither)

16.7-million

Viewing Angle ( 10:1 Contrast )

Horiz = +/-50 , Vert = +/-45 degrees

Chromaticity CIE (x,y)

Red = 0.606, 0.348
Blue = 0.149, 0.360
Green = 0.309, 0.507
White = 0.293, 0.310

Cell Response Time

50. ms

RGB Vert Stripe Pixel pitch (mm)

0.297

Anti-reflective

< 2.0%

Multi-frequency operation

Yes

Horizontal Frequency (kHz)

30 - 61

Vertical Frequency (Hz)

56 - 75

Non-Interlace Video

Yes (all modes)

Video Input (Max) 110 MHz

1024 x 768 @ 75Hz

Corresponding Screen Refresh

1024 x 768 @ 60Hz

Signal cable - detachable

1.8 m

Video

RGB Analogue + separate H&V Syncs

Sync Type 1

Separate H&V sync

Sync Polarity

Positive or Negative

Video connector

15-pin D-Sub

Video Signal Levels

0.700 V p-p

Video Signal Polarity

Positive = Bright

Video Signal Impedance

75 Ohms +/-5% (terminated)

Sync Type 1 Signal Levels

TTL ( High >2.0V, Low <0.8V )

Sync Termination

>2 KOhms

Sync Type 2

Composite sync

Sync Type 3

Sync on green

Sync Type 3 Signal Levels

0.3 V

Sync Polarity

Negative only

User controls

Digital

Lockable controls

Yes

On Screen Display (OSD)

Yes

OSD Languages

5

Factory-preset display modes

10

User display mode settings

10

VESA DDC capable

2B

Apple attach capable

Yes ( with suitable dongle )

ISO 13406 Pt2 capable

Yes

VESA DPMS power mgmt capable

Yes

Power supply

Universal

Power cord - detached

1.8 m

JEIDA compliance

Yes

FCC B compliance

Yes

MPR-2 Emission compliance

Yes

MPR-3 Emission compliance

Yes

TCO92 Compliant

Yes

TCO95 Environmental Label

Yes

Tilt-swivel base

Detachable

Forward tilt (degrees)

-4

Backward tilt (degrees)

+41

Dimensions:

Width

16.3-in (413.0 mm)

Depth

8.1-in (204.3 mm)

Height

15.0-in (380.6 mm) Includes the tilting stand.

Weight

14.3 lb ( 6.5 kg) Includes the tilting stand.


Dimensions and weight of the monitor and stand(unpacked).

Ambient Temperature and Relative Humidity

Parameter

Temperature

Relative Humidity

Altitude

Operating

10 to 35 deg.C

10 to 80 %

0 to 6,500-ft ( 2,000 m)

Shipping

-20 to 60 deg.C

5 to 95 %

0 to 49,200-ft (15,000 m)

Storage

-20 to 60 deg.C

5 to 95 %

0 to 6,500-ft ( 2,000 m)


Compatibility:
Video Adapters
The T55A color monitor has been tested for compatibility with the following PC Video Adapter Cards:

Manufacturer

Video Adpter Card

Video Chip Set

ATI

Xpert@Work

ATI Rage Pro

ATI

All-In-Wonder

ATI Rage II+DVD

Asus

3D Explorer 300

nVidia Riva 128

Diamond

Stealth II S220

Rendition V2100

ELSA

Gloria Synergy

3D Labs Permedia 2

Hercules

Terminator 3D/DX

S3 Virge DX

Leadtek

WinFast 3D L230

3D Labs Permedia 2

Matrox

Millennium

MGA

Matrox

Millennium II

MGA

Matrox

Mystique

MGA

Number 9

FX Reality 334

S3 Virge/GX2

Number 9

FX Reality 772

S3 Virge/VX

STB

Velocity 3D

S3 Virge/VX

Trident

4MB SGRAM AGP

Trident 3D Image 9750

Video Logic

Apocalypse

ET6100


Systems:
The T55A color monitor is supplied with a detachable 1.8 meter video signal cable. This cable has the same 15-pin, D-Sub video connector for system unit connection as previous IBM general purpose monitors. The T55A color monitor has been tested for compatibility with the following PC systems:

System

Machine Type

Video Chip Set

IBM PC 365

6589

Matrox Millenium

IBM PC 300 GL

6282

Cirrus GD-5446

IBM PC 300 XL

6588

S3 Trio 64V2

IBM PC 300 PL

6562

MGA

IBM PC 300 GL

6561

Cirrus 5465 AGP

IBM PC 300 PL

6862

S3 Trio 3D

IBM PC

*

*

IBM IntelliStation Z Pro

6899

Intergraph Intense 3D 1000

IBM IntelliStation M Pro

6898-100

Permedia II AGP

IBM IntelliStation M Pro

6898-140

Intergraph Intense 3D 3000

IBM IntelliStation M Pro

6898-

Matrox Millenium II AGP

IBM Aptiva

2137

ATI 3D Rage 2+

IBM Aptiva ( Jaws 4 )

*

*

IBM Aptiva ( Cobra )

*

*

Non-IBM System Units

*

*

IBM Network Station

8361

S3 Trio 64V+

IBM RS/6000 Workstation

IBM Power Series of Graphics Adapters for RS/6000:
Gt3i, Gt4, Gt4x, Gt4e, Gt4i, Gt4xi
GXT110P, GXT150, GXT150M, GXT150L,GXT150P
GXT250P/255P, GXT500/500D, GXT500P/550P, GXT800P, GXT1000
E15/S15 Graphics Adapters

Sun and HP Workstations

*

*


Hardware Requirements:
The T55A color monitor is designed to operate with system units or video adapters that generate a video output signal that falls within the specifications below:

Maximum addressability (pixels)

1024 x 768

Maximum pixel rate (MHz)

110

Horizontal frequency (kHz)

30 - 61

Vertical frequency (Hz)

50 - 75


National language support is a function of the video adapter in the system unit and the application or support software.

Software Requirements:
The T55A color monitor features factory-preset and user-settable display modes. The actual display modes used depend upon the attaching system unit, the operating system, and application software.

Power Requirements:

Input voltage

90 - 260 V AC

Frequency

50 / 60 Hz

Heat dissipation (Maximum)

136 Btu/Hr

Power consumption (Maximum)

40 watts

Power consumption (Normal use)

< 40 watts typical

Power consumption (VESA Standby)

5 watts maximum

Power consumption (VESA Suspend)

5 watts maximum

Power consumption (VESA Off)

5 watts maximum

Current Leakage

Maximum:
< 3.5 mA @ 260 V
< 2.5 mA @ 100 V


Actual power consumption depends upon the chosen display mode, the images displayed, and user control settings.

Staged monitor power shutdown is controlled by the state of the H- and V-sync lines on the incoming video signal as follows:

Stage

H-Sync

V-Sync

Monitor Status

VESA State

T55A Power

1

Active

Active

Normal Operation

On

< 40. Watts

2

Inactive

Active

Video Off
- Screen blank
- Instant restart

Standby

< 5. Watts

3

Active

Inactive

Video, Scans Off
- Screen blank
- Instant restart

Suspend

< 5. Watts

4

Inactive

Inactive

Off except for microprocessor
- Screen blank
- Delayed restart

Off

< 5. Watts


Factory-Preset PC Display Modes:
The factory-preset modes cannot be overwritten, but can be adjusted to personal choice. The new settings are stored automatically in one of the user locations and are recalled each time that mode is used. The factory settings for the mode in use, if any, can be restored by operating the Geometry Reset/Recall control. It may be necessary to make some adjustments to the displayed image to compensate for variations in video signal timings. The user controls can be used to make these adjustments. Information about the current display mode is shown in the on-screen displays.

Addressability

Incoming Video

Screen Refresh

720 x 400

70 Hz NI (Non-interlaced)

60.0 Hz

640 x 350

70 Hz NI (Non-interlaced)

60.0 Hz

832 x 624

75 Hz NI (Non-interlaced)

60.0 Hz

640 x 480

60 Hz NI (Non-interlaced)

60.0 Hz

640 x 480

75 Hz NI (Non-interlaced)

60.0 Hz

800 x 600

60 Hz NI (Non-interlaced)

60.0 Hz

800 x 600

75 Hz NI (Non-interlaced)

60.0 Hz

1024 x 768

60 Hz NI (Non-interlaced)

60.0 Hz

1024 x 768

70 Hz NI (Non-interlaced)

60.0 Hz

1024 x 768

75 Hz NI (Non-interlaced)

60.0 Hz


There are 10 total factory presets and 10 user locations available.

Ergonomics and Agency Approvals:

Acoustics:

Declared acoustical noise emissions LWAD = 3.7 Bels or less.

The noise emission level stated is the declared (upper limit) A-weighted sound power level, in Bels, for a random sample of monitors. All measurements are made in accordance with ANSI S12.10 and reported in conformance with ISO 9296.

Emissions:

All models meet the emmission category B requirements of Swedish Standard SS-436-14-90 ("MPR-3") in addition to those of MPR-2.

All models meet the Swedish Board for Technical Accreditation (SWEDAC) emission guidelines contained in MPR 1990:10 when tested using the MPR 1990:08 test method.

The monitors also meet the TCO95 Environmental Label from the Swedish Confederation of Professional Employees (TCO), and the emission, power management, and electrical safety requirements of the TCO95 Environmental Label.

Ergonomics:

Compliance to the International Organization for Standardization (ISO) 13406 Pt 2 for improved ergonomics and image quality is provided when the monitor forms part of an ISO-compliant system.

Regulatory
Agency
Approvals:

UL (U.S.)
CSA (Canada)
IEC950 CB Report
TUV EN 60950 (Germany)
NEMKO (Norway)
Korean Safety Reg No 776
SEMKO (Sweden)
DEMKO (Denmark)
FIMKO (Finland)
CCIB/CCEE (China)
NOM (Mexico)
SASO (Saudi Arabia)
CE (Europe)
GOST (Russia)
SISIR (Singapore)
MEEI (Hungary)
PCBC (Poland)
EZU (Czech)
FCC B (U.S.) (A3KM078)
IC (Canada)
CE (Europe)
EN 55022 B (Europe)
EN 50081 B (Europe)
VCCI (Japan)
Korea EMI Reg No 825
Australia
New Zealand
South Africa SABS
BCIQ (Taiwan)

Environmental,
Energy,
Ergonomic,
Compatibility Approvals:

MPR-2 (Sweden)
MPR-3 (Sweden)
TCO95 (Sweden)
NUTEK (Sweden)
ENERGY STAR (U.S.)
GS (Germany) ZH1/618/10.80
ISO 9241 Pt 3
ISO 9241 Pt 8
ISO 13406 Pt 2 ( Target )
Windows** 95/98


** Trademark of Microsoft Corporation.

OSD Controls
Digital user controls are located on the front bezel, to the left of the power on/off pushbutton. Adjustments are made in conjunction with the on-screen displays. After adjustments are made, the controls can be locked to prevent further changes. With exception of Brightness & Contrast all the controls are lockable.

Control

T55A Monitor

Auto Setup

Y

Coarse Clock for FOS adjust

Y

Fine Clock for FOS adjust

Y

Brightness (not lockable )

Y

Contrast (not lockable)

Y

Screen Expansion on/off

Y

Image Horizontal position

Y

Image Vertical position

Y

Geometry reset/recall

Y

OSD Language selection

Y (1)

OSD Menu Position

Y

OSD information : Video Mode

Y

OSD Horizontal position

Y

OSD Vertical position

Y

OSD Information....Mode Data

Y

Preset color selection

3 Modes

R,G,B gain adjustment

Y

Color point recall

Y

Controls lock/unlock

Y


(1) Languages available in the OSD are English, French, German, Italian and Spanish.

Indicators
The power indicator LED indicates the operational state of the monitor:

Indicator

T55A Operating State

Power Use

Steady green

Normal operation

<40 Watts

Steady amber

DPMS - Standby state

< 5 Watts

Amber blink @ 0.5Sec

DPMS - Suspend state

< 5 Watts

Amber blink @ 1.0Sec

DPMS - Off state

< 5 Watts


A 'No Connection / Check signal cable' message appears in the OSD whenever the monitor detects no incoming video signal. Whenever the monitor detects a video signal that is outside its operating range the LED will flash at a rate, specified in the "User Guide" to indicate that there is a problem.

Limitations:

Supported display modes are a function of the attaching system unit. The full range of display modes available with these monitors may not be available or supported with all combinations of system units, their operating systems, and application software.

Horizontal and vertical sync signal timings are critical in order to achieve acceptable screen images. As a consequence, support for all possible variations in H- and V-sync timings for any display mode cannot be assumed.

Adjustment of the user controls to enlarge the image to its maximum size requires that the signal timings of the display mode being used fall within the monitor timing specifications.

The number of colors shown in any display mode (max = 16.7 million) is not limited by the monitor, but depends upon the capabilities of the video adapter in the system unit.

The T55A provides FCC class B - residential installation - compliance in all display modes

Implementation of monitor power management follows the Video Electronics Standards Association (VESA) Display Power Management Signaling (DPMS) standard. This standard must also be implemented in the attaching system unit hardware and software for monitor power management to be effective. The system implementation must provide user-adjustable, power-down delay periods. The monitor power management function is invoked only after appropriate signals are received from an attached system unit or video adapter.

Implementation of monitor Plug and Play follows the VESA Display Data Channel (DDC) standard. This standard must also be implemented in the attaching system unit hardware and software for monitor Plug and Play to be effective.

Certain functions require the system unit to be similarly configured, so all monitor functions may not be enabled when attached to a particular system unit.


Document Note(s):

1.

The symbols, * and [*], are used to denote that the information is currently unavailable for this product.

2.

N/A is used to denote that there is no applicable information for this product.

3.

Multiple ordering information gives the partnumber that can be used to order the product in bulk.

4.

Geo is used to denote the Geography to which the information is applicable.

5.

All dates are represented in the US English format of mm/dd/yyyy (where mm=month, dd=day, yyyy=year).

6.

Effective Withdrawal means that on the given date IBM will have withdrawn the products from marketing. After that date, customers will no longer be able to obtain the product(s) directly from IBM.


Search Keywords

Document Category

Technical Specifications

Date Created

31-08-98

Last Updated

20-01-99

Revision Date

20-01-2000

Brand

IBM Monitors

Product Family

Flat Panel

Machine Type

9513

Model

AW1; AG1

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes