Preloaded Software Information

Document ID: DDSE-3TRJ75

PC Server 330 - Installing OS/2 Warp Server 4 Advanced (8640-PB0, PM0, PT0)

Applicable to: World-Wide

Supported Systems:
8640 - PT0, PB0, PM0

What you will need:
- Flat head screw driver.

- Supported hard drive (refer to http://www.us.pc.ibm.com/compat/ for a list of supported options and part numbers for your IBM Server).

- Licensed copy of OS/2 Warp Server 4 Advanced

- Ethernet Support Diskette. This diskette can be downloaded from the IBM BBS or FTP site (see next section for more information).

- PC ServeRAID Device Driver and Utilities Diskette version 2.23A (part number 4306765) or later version, and PC ServeRAID Configuration Diskette version 2.23 (part number 4227013) or later version. These diskettes ship with the RAID Adapter or you can get the filenames 05L1955.EXE and 4227013.EXE from the IBM BBS, FTP site, or Web site (see next section for more information)

- OS/2 Device Driver for S3 TRIO 64V+ Diskette (part number 4306788). This diskette ships with the system or you can get filename 4306788.EXE from the IBM BBS or FTP site (see next section for more information).

- OS/2 FixPak 32 or later. This is available from the sites listed in Appendix B.

- LANServer FixPak IP08267. This is available from the sites listed in Appendix B.

- MPTS FixPak WR08415. This is available from the sites listed in Appendix B.

Where to download drivers/files:
IBM BBS (U.S.) 1-919-517-0001
IBM FTP site: ftp://ftp.infania.net/pccbbs/pc_servers/
IBM US web site: http://www.us.pc.ibm.com/searchfiles.html
For IBM PC sites in other countries, begin at: http://www.pc.ibm.com

(For users who are very familiar with SCSI, hardware, and install process, jump to Appendix A)

Setting Up the Hardware:
1. Looking at the rear of the system, loosen the 3 thumb screws on the right of the system and remove the side access panel.

2. For the initial install, it is recommended that you remove all adapters and devices that are not required to get the base operating system installed. (For example, if installing multiple network adapters, only install one at this time). If a tape drive or external SCSI devices will be used, just disconnect them temporarily. After the operating system is booting without errors, add these devices one at the time. This procedure streamlines the install process.

3. Verify that the SCSI cable (part number 76H3452) runs from the on-board RAID controller to the top of the hot-swap backplane, and that there is a second SCSI cable (part number 76H3454) running from the bottom of the hot-swap backplane to the CD-ROM.

4. Install the desired number of hot-swap hard drives into the hot-swap bays beginning at the top and proceeding downward.

IMPORTANT NOTE: OS/2 currently only supports one CD-ROM device installed in the server during NOS installation. Additional CD-ROM devices can be installed into the server AFTER Completion of the NOS installation (Refer to APAR PJ24628 for more information). Verify that there is only one CD-ROM device in the server before continuing.

Setting Up the BIOS:
1. Power on the system and press F1 to enter Configuration/Diagnostics.

2. Press Enter to select Configuration/Setup Utility.

3. Select Date and Time and verify the settings. Then press Esc to return to the main menu.

4. Select Start Options and verify that the First Startup Device is set to Diskette Drive 0 and the Second Startup Device is set to Hard Disk 0. Press Esc to return to the main menu.

5. If any ISA devices are installed (or will be installed) that need IRQs (or other system resources such as I/O ports or memory) reserved, choose Plug and Play and then the desired resource type you wish to reserve. Change the desired resource from Plug and Play to ISA Legacy. From the Plug and Play window, press Esc and select Save Settings. Press Enter and then select Exit Setup. Press Esc and Enter to select Yes, save and exit the Setup Utility.

6. The server will reboot (If you receive a 162 Configuration Change has Occurred message during post, press Enter to select Continue, then Enter again. At the Diagnostic/Setup Utility window, press Esc and then Enter to select Yes, save and exit the Setup Utility).

Configuring Arrays Using the PC ServeRAID II Adapter:
1. Upon initial boot, an error message similar to the following may be encountered:

- Following drives not responding (oldstate:newstate:ch:bay)
(ONL:DDD:2:1)(ONL:DDD:2:2)
Identifiers for the following drives do not match configuration ...

Press F10 - Exit without change and boot to the PC ServeRAID Configuration Diskette Version 2.23 selecting Advanced Functions, then Init/View/Synchronize Config and finally Initialize Configuration. Confirm initialization request with a Yes.

2. After initializing, exit to the main menu and select Create/Delete/Copy Log Drive.

3. Select Create Disk Array.

4. Use the arrow keys to select RDY drives for each new array. Press Enter on each highlighted drive to add it to the array.

5. Press Esc when finished selecting drives.

6. Select Define Logical Drive.

7. Select an array to define a drive on.

8. Specify the raid level for the new logical drive.

9. Specify size for the new logical drive (The maximum size for a logical drive under OS/2 Warp Server 4 Advanced is 45 GB), and confirm with a Yes.

10. A message stating that All logical drives must be INITIALIZED after being created pops up press Enter. Confirm command to initialize the new logical drive with a Yes. If a RAID-5 logical drive was defined, a message stating that All RAID-5 logical drives must be SYNCHRONIZED after
initialization pops up. Confirm synchronization of the new logical drive with a Yes. The synchronization process may take several hours to complete per logical drive.

11. After synchronization, Esc to the main menu. Choose Advanced Functions, and then backup IPS ServeRAID Config.

12. Verify that the PC ServeRAID Configuration Diskette Version 2.23 is not write-protected.

13. Enter the file name you wish to save the Config to, or press Enter to accept the default, then Yes to confirm.

14. Exit the utility, ignoring the message to back up the RAID configuration, again confirming with a Yes.

Running the OS/2 Warp Server 4 Advanced Installation Program Using the PC ServeRAID II:
1. On a separate machine, copy IPSRAID.ADD from the PC ServeRAID Device Driver and Utilities Diskette Version 2.23A onto the OS/2 Diskette 1 for CD-ROM. Using a standard text editor, add the following line to the top of CONFIG.SYS on the OS/2 Diskette 1 for CD-ROM:
BASEDEV=IPSRAID.ADD

2. Insert Installation Diskette for CD-ROM into the floppy drive and the OS/2 Warp Server Version 4 Advanced CD into the CD-ROM drive and boot the server.

3. Insert OS/2 Diskette 1 for CD-ROM when prompted.

4. Press Enter at the Welcome! screen.

5. Select Advanced Installation.

6. Select 2. Specify a different drive or partition.

7. Press Enter twice, then select Create Partition... Enter the size of the partition. The boot partition must be on the first logical drive created (either the first physical drive for non-array configurations or, the first logical drive on the first RAID array for RAID configurations) and must NOT exceed 2000 MB in size. All other partitions can be up to 45 GB in size using HPFS386 and, 2048 MB for FAT partitions.

8. Select Primary Partition for the first partition and Logical Partition for all others.

9. Select Create at Start of FreeSpace.

10. Repeat this until all space on the drive has been allocated to partitions.

11. Press Tab to change to different logical drives and repeat steps 7 - 10 until all logical drives are allocated.

12. Go back to the first logical drive and use the arrow keys to choose the partition you want to contain the operating system.

13. Press enter to bring up FDISK options again and select Set Installable.

14. Name the partition.

15. Press F3 twice to exit the FDISK program.

16. Reinsert Installation Diskette for CD-ROM into the floppy drive and reboot the server.

17. Insert OS/2 Diskette 1 for CD-ROM when prompted.

18. Press Enter at the Welcome! screen.

19. Select Advanced Installation.

20. Select 1. Accept the drive.

21. Select HPFS or FAT file system and press enter to format the installation partition.

22. After formatting, OS/2 will perform an operating system file copy. When the file copy is complete, remove the OS/2 Diskette 1 for CD-ROM then press Enter reboot the server.

23. You will receive a Virus Warning on reboot, this is normal. Select Change is expected.

24. At the System Configuration screen. select OK, or select any items you wish to configure (although these may be added after installation) and then select OK.

25. Select a default printer or, accept no default printer and select OK.

26. Accept default SVGA video driver and select OK, then select OK again at System Configuration screen.

Note: If you intend on using the S3 TRIO 64V+ device driver which shipped with the system on the OS/2 Device Drivers for S3 TRIO 64V+ Diskette V3.03.14 diskette (part number 4306788) to allow higher video resolutions, use the VGA video driver during NOS installation. You can only install this new video driver AFTER the NOS installation is complete. Review Appendix C for full driver installation details.

27. At the OS/2 Setup and Installation screen, uncheck any additional products you will not need and select Install. (By default, all items are selected)

Note: If you plan on installing with multiple CD-ROM drives, do not select the MMOS/2 option.

28. Under Advanced Options, select add existing programs to your desktop and select OK.

29. At the Information screen, input your personal information and select OK. This step is optional.

30. At the OS/2 Warp Server Setup and Installation screen, check any additional services you require and select OK.

31. At Configuration Screen, select any red arrows and configure necessary options. All gray checks denote default settings, which you may accept or change (it is recommended that all default values at least be reviewed). Teal checks represent acceptably configured and reviewed options.

32. Select the bottom check mark for Adapter and Protocol Services. Add any additional network adapters and necessary protocols. If you are using the integrated 10/100 Mbps Ethernet adapter, select Change Adapter, then Other Adapter. Insert Ethernet Support Diskette 1 of 2 into the floppy drive and select OK. Select AMD PCNet Family Ethernet Adapter and under Type of LAN select Ethernet and select OK.

33. When all options are correctly configured, select Install, then OK to complete the installation.

34. The primary copy then begins, Installation of Warp Server SMP is complete. The system will reboot twice before file copying is complete.

35. Install FixPak 32 or later, LANServer FixPak IP08267 and, MPTS FixPak WR08415. See Appendix C for further details.

Appendix A
Quick Install for Experienced Users:

Note: OS/2 currently only supports one CD-ROM device installed in the server during NOS installation. Additional CD-ROM devices can be installed into the server AFTER Completion of the NOS installation (Refer to APAR PJ24628 for more information). Verify that there is only one CD-ROM device in the server before continuing.

1. Install the desired number of hot-swap hard drives into the hot-swap bays beginning at the top and proceeding downward.

2. If any ISA devices are installed (or will be installed) that need IRQs (or other system resources such as I/O ports or memory) reserved, go into the BIOS settings and choose Plug and Play and then the desired resource type you wish to reserve. Change the desired resource from Plug and Play to ISA Legacy.

3. From the ServeRAID Driver and Utilities Diskette Version 2.23A, copy IPSRAID.ADD onto OS/2 Diskette 1 for CD-ROM. Using a standard text editor, edit the CONFIG.SYS on the same diskette adding the following line to the top of the file:
BASEDEV=IPSRAID.ADD

4. After formatting, OS/2 will perform an operating system file copy. When the file copy is complete, remove the OS/2 Diskette 1 for CD-ROM then press Enter to reboot the server.

5. At the OS/2 System Configuration screen, accept default SVGA video driver and select OK, then select OK again at System Configuration screen.

Note: If you intend on using the S3 TRIO 64V+ device driver which shipped with the system on the OS/2 Device Drivers for S3 TRIO 64V+ Diskette V3.03.14 diskette (part number 4306788) to allow higher video resolutions, use the VGA video driver during NOS installation. You can only install this
new video driver AFTER the NOS installation is complete. Review Appendix C for full driver installation details.

6. At the Warp Server System Configuration screen, select the bottom check mark for Adapter and Protocol Services. Add any additional network adapters and necessary protocols. If you are using the integrated 10/100 Mbps Ethernet adapter, use the AMD PCNet Family Ethernet Adapter driver off of the Ethernet Support Diskette.

7. Install FixPak 32 or later, MPTS FixPak WR08415, and LANServer 5.0 FixPak IP08267 as directed in Appendix B.

Appendix B
Installing FixPak 32, MPTS WR08415 and, LANServer IP08267 on OS/2 Warp Server 4 Advanced
WHERE YOU CAN FIND FIXPAK 32 AND RELATED NECESSARY FIXES:

FixPak 32: ftp://ftp.software.ibm.com/ps/products/os2/fixes/v3.0warp/english-us/xr_w032/
LANServer IP08267 ftp://ftp.software.ibm.com/ps/products/lan/fixes/lsv5.0/english-us/ip08267/
MPTS WR08415 ftp://ftp.software.ibm.com/ps/products/mpts/fixes/english-us/wr08415_conv/

Note: The above filenames and directories may vary slightly depending upon the language you choose to use. Beginning at the ftp://ftp.software.ibm.com/ps/products/<PRODUCT>/fixes/ directory enables choosing different language FixPaks (where <PRODUCT> is one of the three products listed in the above FTP sites).

WHERE YOU CAN FIND CSF (Corrective Services Facility) (excerpted from README.1ST of FixPak 32)

The Corrective Service Facility disk images are available in the WKICKR.ZIP file from many places, including, but not limited to, the following:

Source

How to access

CompuServe

Subscribers can download from the OS/2 Support Forum
(GO OS2SUPPO), in Library 23, IBM FILE.

IBM OS/2 BBS

Subscribers can download from the Software Download Library.
U.S. customers who are not subscribers can call 1-800-547-1283 for information on how to subscribe.

Internet(FTP)

Anonymous FTP to ftp.software.ibm.com (IP Address 198.17.57.66) in the "/ps/products/os2/fixes" directory.

Internet(WWW)

Point your Web Browser at:
ftp://service.boulder.ibm.com/ps/products/os2/fixes

Prodigy

Subscribers can download from the OS2CLUB in the Download Library, IBM Files, Fixes area. Files are updated weekly and are available on Friday.

PCC BBS

Customers can call the IBM Personal Computer Company BBS in
Raleigh NC, and download from the public area. You can access this BBS at 1-919-517-0001.

AOL

America OnLine subscribers can download from the OS/2 Area.



Follow the instruction contained in the WKICKR.TXT file to create the Corrective Service Facility disks. Label them as:

CSF DISK Diskette 1
(SP DISK 1)

CSF DISK Diskette 2
(SP DISK 2)

Creating Fixpak Diskettes
Use LOADDSKF.EXE to create the diskettes. For each disk image, place a 2MB HD (1.44MB formatted) diskette in A:.

Warning: DO NOT use a 1MB (720KB formatted) diskette because you might have problems trying to install this FixPak.

For each diskette image in the FixPak, do the following:

Enter LOADDSKF XR_W032.?DK A: /F (? can be 1 through 9, A through Z).

Label the diskette as:

FixPak XR_W032
Corrective Service Diskette ?
(CSF DISK ?)

Note: For diskette images ADK through ZDK (if they exist), use the numbers 10 through 36.

Examples:
XR_W032.ADK = Corrective Service Diskette 10 (CSF DISK 10)
XR_W032.BDK = Corrective Service Diskette 11 (CSF DISK 11)
XR_W032.CDK = Corrective Service Diskette 12 (CSF DISK 12)
XR_W032.DDK = Corrective Service Diskette 13 (CSF DISK 13)
etc.

Installation Process

Before Installation
Before installing any FixPak, run CHKDSK /F against all drives on your system to correct any file system errors that might be present. You cannot do this while OS/2 is active. You must shut down and run CHKDSK by one of the following methods:
- Boot from your Installation and DISK 1 diskettes you used to install OS/2 with. If your file system is HPFS, then put the diskette with CHKDSK and UHPFS.DLL on it in your A: drive before issuing the CHKDSK command.
- Boot from the Utilities disk you created via the Create Utility Diskettes icon in the System Setup folder.
- Boot from a different OS/2 partition.

Install From Booted OS/2 Partition
Note: You can use a diskette drive other than A: with this method. If your 3.5" diskette drive is B:, use B: where A: is mentioned in the following steps. (this method only).
1. Insert CSF DISK Diskette 1 in drive A.

2. Open an OS/2 window or full-screen session.

3. Type A:\SERVICE and press the Enter key.

Note: You could also use the Drives object for A: and double select the SERVICE.EXE Icon to start the install.

4. Follow the displayed instructions. When prompted to insert Corrective Service Diskette 1 (not CSF DISK Diskette 1), place FixPak XR_W032 Corrective Service Diskette 1 in drive A. Repeat for the rest of the FixPak disks when requested to do so.

Note: It can take a considerable length of time for the Corrective Service Facility to scan your hard disk for serviceable files. In some cases, it has taken as long as 40 minutes. Please be patient and allow this process to complete.

5. If this is the first OS/2 Warp FixPak you have applied to this system, then enter the path to the ARCHIVE directory where a copy of replaced files will be stored (for example, D:\ARCHIVE).

Note: This ARCHIVE directory is not related to the ARCHIVES directory built into OS/2 Warp 3.0. Please specify a different path. You must specify a different ARCHIVE directory for each product to be serviced.

If this is not the first OS/2 Warp FixPak, then enter the path to the BACKUP directory where a copy of replaced files will be stored (for example, D:\BACKUP).

Note: You must specify a different BACKUP directory for each product to be serviced.

For either case, make sure there is sufficient space available on the drive you specify. Even though these files are kept in compressed (PACK2) format, they require between 7 and 12 MB of disk space.
6. Select OK.

7. You will see an Application in use dialog box showing a list of locked files that cannot be serviced while the system is running. You are given two choices - to Continue or Reboot. Select Continue.

8. During the installation process you might see messages about Archiving, Updating and Deferring service.
- Archiving saves a compressed copy of the original file in the ARCHIVE or BACKUP path you specified.
- Updating means the original files are replaced with the new ones from this FixPak.
- Deferring service means the file to be updated is currently in use by the system and cannot be updated. The new files from the FixPak are placed in unpacked format in the \IBMCSFLK\FIX directory on the drive with the most free space. They are processed by the locked file device driver during reboot after you shut down the system.

9. Select NO for a redisplay of the Product List after the first part of the FixPak application process has completed if this message is displayed.

10. Select Cancel and Exit to close the Corrective Service Facility window if necessary.

11. Shut down and reboot your system.

You will see the following during reboot of the system if you applied service to the OS/2 partition you were booted from:
The locked file driver is loaded.
Processing locked files
Processing complete

The system will do one automatic reboot after the Locked File Device Driver has completed.

Installing MPTS WR08415 FixPak:
Note: This FixPak is a refresh of the MPTS LAN Adapter and Protocol Support program and is intended to replace (upgrade) only LICENSED instances of MPTS. This version of MPTS is installed using the MPTS Program Product Installation Aid, MPTS.EXE. There is NO selective install of MPTS sub-components. All components of MPTS are installed, including all of the MAC drivers. Please refer to the MPTS Configuration Guide on Diskette 6 for complete Installation and Configuration details.

1. Download the diskettes from the above mentioned FTP.

2. Once downloaded, diskettes can be in the same manner as the CSF diskettes using LOADDSKF.

3. Apply this FixPak in the same manner as FixPak 32 using the same CSF DISKETTES 1 and 2.

Installing LANServer IP08267 FixPak:
Note: IP08267.INF, located on the first FixPak diskette, contains installation, and other useful information about this FixPak. Please review before installation of service.

1. Once downloaded, diskettes can be in the same manner as the CSF diskettes using LOADDSKF.

2. Apply this FixPak in the same manner as FixPak 32.

Appendix C
Installing the S3 TRIO 64V+ Device Driver:
(an excerpt from README.TXT off of OS/2 Device Driver for S3 TRIO 64V+ Diskette (part number 4306788).
1. Reboot the server in VGA mode. If the server was not installed in VGA mode, this can be accomplished by pressing ALT+F1 when the OS/2 logo appears in the upper left hand corner of the monitor during boot. From the Recovery Choices screen, press V to reset primary video display to VGA and reboot.
2. Insert OS/2 Device Driver for S3 TRIO 64V+ Diskette (part number 4306788). into drive A (or any other diskette drive). In the following sequence the A drive is assumed.
3. Open an OS/2 full-screen or OS/2 window session.
4. At the OS/2 command prompt, type the following command to copy all necessary files to the OS/2 drive:
A:SETUP where A: is the diskette drive which contains the device driver installation diskette. Then press Enter. Due to the limitations with a single pass installation. A dialog box may come up during installation with the message, The installed adapter does not support the selected display driver. Do you wish to continue?. Please continue the installation by selecting the Yes button.
5. When the Monitor Configuration/Selection Utility window appears, the Install Using Defaults for Monitor Type choice is preselected. Select OK. Do not select Install Using Display Adapter Utility Program since this method of setting refresh rates is not supported anymore.

Note: DSPINSTL determines the hardware configuration by creating the \OS2\SVGADATA.PMI file. If the \OS2\SVGADATA.PMI file has not been created, the adapter will not be supported. This process can take several seconds and will black-out the screen.

6. When the Source Directory pop-up window appears, insert the prompted graphics-accelerator driver diskettes into drive A. At this point the source directory must specify the drive containing the installation diskette (e.g. A:). If necessary change the source directory, then select Install.

7. When the installation is complete, shut down your system, remove the diskette, and restart your computer.

8. When the system has restarted:
a. Open the OS/2 System folder.
b. Open the System Setup folder.
c. Open the System object.
d. When the Settings notebook appears, select the Screen tab.
If your monitor has been detected as Plug and-Play (DDC) compatible, go to step 10.

9. On Screen page 2, select your display from the display list. If your display does not appear in the list, select Default. It might be necessary to restart your computer to have all refresh rate options available.

10. When the system has restarted:
a. Open the System object and select Screen page 1, as in step 8.
b. Select a screen resolution and a screen refresh rate.
c. Close the Settings notebook.
d. Perform a shutdown and restart your computer.

Notes:
- If the selected vertical refresh rate is not supported by your monitor, delete \OS2\VIDEO.CFG file and reboot. This will set the refresh rate to the default value. A new refresh rate can now be selected using the procedure described above.

- During the installation of this driver, DISPLAY.LOG and DSPINSTL.LOG files are created in the OS/2\INSTALL directory. These files identify the OS/2 system files that were updated and indicate whether the installation was successful. The contents of these files might be useful if you need to report an installation problem.

- If the video memory size is changed after the device driver is installed, the device driver must be reinstalled in order for the system to recognize the change. Not reinstalling the driver might result in serious system problems.

- When starting a Windows session from a DOS command line, use the WINOS2 command rather than the WIN command. Additionally, you must modify the C:\AUTOEXEC.BAT file. Place the following line anywhere after the @ECHO.OFF line in the AUTOEXEC.BAT:
COPY C:\WINDOWS\WINOS2.COM C:\WINDOWS\WIN.COM

Software Product:
Version:
Vendor:
EDOC Number:
Announce Date:
GA Date:
Service End Date:
Program Services:

Search Keywords

Document Category

OS/2

Date Created

21-04-98

Last Updated

02-09-98

Revision Date

01-09-99

Brand

IBM PC Server

Product Family

PC Server 330

Machine Type

8640

Model

PB0; PM0; PT0

TypeModel

Retain Tip (if applicable)