IBM ValuePoint - Type 6384 specifications

Applicable to: World-Wide

Specifications (6384):
(Minimum configuration)

System Unit Size:
Width: 404 mm (15.9 in.)
Depth: 420 mm (16.5 in.)
Height: 147 mm (5.8 in.)

System Unit Weight:
9.7 kg (21.4 lb)

Environment:
Temperature (System Unit and Display)
- Power on: 10 to 35 degrees C (50 to 95 degrees F)
- Power off: 10 to 43 degrees C (50 to 110 degrees F)

Humidity (System Unit and Display):
- Power on: 8% to 80%
- Power off: 8% to 80%

Maximum altitude:
2134 m (7000 ft.)

Heat output:
120 BTU/hr

Electrical:
- Input voltage (sinewave input is required)ý Low Range
Minimum: 90 V ac
Maximum: 137 V ac

High Range:
Minimum: 180 V ac
Maximum: 265 V ac