3.048 bytes |
Service Hints & Tips |
Document ID: MCGN-42CHUU |
This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose. |
Netfinity 3000 - Push-down tab in Bay 3 interferes with tape drive function
Applicable to: World-Wide
Source: RETAIN tip H165264
Abstract:
Push-down tab in Bay 3 interferes with Tape Drive function.
SYMPTOMS:
Unable to remove cartridge from TR4 or TR5 tape drives.
PROBLEM ISOLATION AIDS:
The system is a Netfinity 3000 server, Type 8476, any model.
FIX:
Shell has been EC'd to remove the tab. It is not needed.
WORKAROUND:
Tab must be reformed upward to clear option in Bay 3, but not too far which would interfere with Bay 2.
DETAILS:
Proper tab deflection is achieved by pushing upward on the tab until the lowest part of its curved surface is approximately 1.25mm (0.050") below the top of Bay 3. Be careful not to deflect the tab too far.
SAS KEYWORDS:
PSY2, D/T8476, NETFINITY, SERVICER ONLY, TAPE, FIT, FUNCTION, 10725, CARTRIDGE, EJECT, PUSHDOWN, TR4,
TR5, BAY3, 0.050", 1.25mm
Search Keywords |
PSY2, D/T8476, NETFINITY, SERVICER ONLY, TAPE, FIT, FUNCTION, 10725, CARTRIDGE, EJECT, PUSHDOWN, TR4 | |
Hint Category |
Retain | |
Date Created |
18-11-98 | |
Last Updated |
14-01-99 | |
Revision Date |
14-01-2000 | |
Brand |
IBM PC Server | |
Product Family |
Netfinity 3000 | |
Machine Type |
8476 | |
Model |
ALL | |
TypeModel |
| |
Retain Tip (if applicable) |
H165264 | |
Reverse Doclinks |
Date last altered: A98/12/03 |