2.613 bytes |
Product Information |
Document ID: DDSE-42CSFK |
Netfinity 3000 - Undetermined Problems
Applicable to: World-Wide
Undetermined Problems
You are here because the diagnostic tests did not identify the failure, the Devices List is incorrect, or the system is inoperative.
Notes
If you suspect a software mismatch is causing failures (solid or intermittent),
be sure to see "Configuration Conflicts" on page 20. |
Check power supply. If the LEDs indicate the power supplies are working correctly, return here and do the following:
1. Power-off the computer.
2. Remove or disconnect the following (one at a time) until you find the failure (power-on the computer and reconfigure each time).
- Any external devices
- Surge suppressor device (on the computer)
- Modem, printer, mouse, or non-IBM devices
- Each adapter
- Drives
- Memory-Module Kits (Minimum requirement = 1 bank of 64 MB DIMMs)
Note
Minimum operating requirements vary for each computer.
For example, an IML drive in the drive startup sequence
(IML systems only). |
3. Power-on the computer. If the problem remains, suspect the following FRUs in the order listed:
- System Board
- Processor Board
- Front Panel
Note
If the problem goes away when you remove an adapter from the system, and replacing that adapter does not correct the problem, suspect the system board then the processor board(s) |
|
Search Keywords |
|
|
Document Category |
Diagnostics |
|
Date Created |
18-11-98 |
|
Last Updated |
23-11-98 |
|
Revision Date |
18-11-99 |
|
Brand |
IBM PC Server |
|
Product Family |
Netfinity 3000 |
|
Machine Type |
8476 |
|
Model |
ALL |
|
TypeModel |
|
|
Retain Tip (if applicable) |
|
|
Reverse Doclinks
and Admin Purposes |
|