IBM PC100/PC140 - Numeric error codes
Applicable to: World-Wide
Numeric Error Codes
In the following index, "X" can represent any number.
Error Code |
FRU/Action |
02X |
1. SCSI Adapter |
08X |
1. SCSI Cable |
101 |
1. System Board |
102 |
1. System Board |
106 |
1. System Board |
110 |
1. Memory Module |
111 |
1. Reseat adapters |
114 |
1. Memory Module |
129 |
1. Processor |
151 |
1. System Board |
161 |
1. Run Setup |
162 |
1. Diskette Drive |
162 |
1. Run Setup |
163 |
1. Time and Date Set? |
164 |
1. Run setup. Check System Summary menu for memory size change. |
17X, 18X |
1. C2 Security |
175 |
1. Riser Card |
176 |
1. Covers were removed from the computer. |
177 |
1. Riser Card |
178 |
1. Riser Card |
183 |
1. Enter the administrator password |
184 |
1. Enter new password |
185 |
1. Set configuration and reinstall the boot sequence. |
186 |
1. Riser Card |
189 |
1. More than three password attempts were made to access the computer. |
1XX |
1. System Board |
201 |
1. Memory Module |
225 |
1. Unsupported Memory |
229 |
1. L2 Cache Memory |
262 |
1. Run Setup. Check System Summary menu for memory type change |
301 |
1. Keyboard |
303 |
1. Mouse |
303 |
1. Keyboard |
3XX |
1. Keyboard |
5XX |
1. Display Adapter (if installed) |
601 |
1. Diskette Drive A |
604 |
1. Diskette Drive A |
604 |
1. Diskette Drive B |
605 |
1. Diskette Drive |
662 |
1. Diskette drive configuration error or wrong diskette drive type, run Set Configuration. |
6XX |
1. Diskette Drive |
762 |
1. Run Setup |
7XX |
1. Math Coprocessor |
962 |
1. Run Setup |
9XX |
1. Printer |
1047 |
1. 16-Bit AT Fast SCSI Adapter |
107X |
1. Check SCSI terminator installation. |
1101 |
1. Run Diagnostics |
1101, 1102, 1106, 1108, 1109 |
1. System Board |
1107 |
1. Communications Cable |
1102 |
1. Run Diagnostics |
1103 |
1. Run Diagnostics |
1106 |
1. Run Diagnostics |
1107 |
1. Serial Device Cable |
1110 |
1. Run Diagnostics |
1116 |
1. Run Diagnostics |
1117 |
1. Run Diagnostics |
1162 |
1. Run Setup |
11XX |
1. System Board |
1201 |
1. System Board |
1202, 1206, 1208, 1209, 12XX |
1. Dual Async Adapter |
1207 |
1. Communications Cable |
13XX |
1. Game Adapter |
1402 |
Information only |
1403 |
Information only |
1404 |
1. Run Diagnostics |
1405 |
1. Run Diagnostics |
1406 |
1. Run Diagnostics |
14XX |
1. Printer |
15XX |
1. SDLC Adapter |
1692 |
1. Run FDISK to ensure at least one active partition is set active. |
16XX |
1. 36/38 Workstation Adapter |
1762 |
1. Run Setup |
1780 (Disk Drive 0) |
1. Power Supply |
1962 |
1. Possible hard disk drive problem |
209X |
1. Diskette Drive |
20XX |
1. BSC Adapter |
21XX |
1. SCSI Device |
2401, 2402 |
1. Display |
2401, 2402 |
1. System Board |
2409 |
1. Display |
2410 |
1. System Board |
2462 |
1. Run Setup |
3015, 3040 |
1. Network Attached? |
30XX |
1. PC Network Adapter |
3115, 3140 |
1. Network Attached? |
31XX |
1. Alternate PC Network Adapter |
36XX |
1. GPIB Adapter |
38XX |
1. DAC Adapter |
5600 |
1. Financial System |
5962 |
1. Run Setup |
62XX |
1. 1st Store Loop Adapter |
63XX |
1. 2nd Store Loop Adapter |
64XX |
1. Network Adapter |
71XX |
1. Voice Adapter |
74XX |
1. Display Adapter (if installed) |
76XX |
1. Page Printer Adapter |
78XX |
1. High Speed Adapter |
79XX |
1. 3117 Adapter |
80XX |
1. PCMCIA Adapter |
84XX |
1. Speech Adapter |
8601, 8602 |
1. Pointing Device (Mouse) |
8603, 8604 |
1. System Board |
86XX |
1. Mouse |
89XX |
1. PC Music Adapter |
91XX |
1. Optical Drive |
96XX |
1. SCSI Adapter |
10101, 10102, 10104 |
1. Have customer verify correct operating system device drivers are installed and operational. |
10103, 10110, 101171 |
1. System Board |
10117 |
1. Check system speaker |
10118 |
1. Run Diagnostics and verify the correct operation of the modem slot |
10119 |
1. Diagnostics detected a non-IBM modem |
10120 |
1. Check PSTN Cable |
10132, 10133, 10134 |
1. Modem |
10153 |
1. Data/Fax Modem |
101XX |
1. Modem Adapter |
10450, 10451, 10490 |
1. Run Diagnostics |
10452 |
1. Run Diagnostics |
10453 |
Information only |
10454 |
1. Run Diagnostics |
10455, 10456 |
1. Run Diagnostics |
10459 |
Information only |
10461 |
1. Run Diagnostics |
10462 |
1. Run Diagnostics |
10464 |
1. Run Diagnostics |
10467 |
1. Run Diagnostics |
10468 |
1. Run Diagnostics |
10469 |
1. Run Diagnostics |
10470, 10471, 10472 |
1. Run Diagnostics |
10473 |
Information only |
10480 |
1. Hard Disk Drive (ESDI) |
10481 |
1. Run Diagnostics |
10482 |
1. Run Diagnostics |
106X1 |
1. Check Configuration |
10635 |
1. Power-off computer, wait ten seconds; then |
10651, 10660 |
1. Check Cables |
106XX |
1. Ethernet Adapter |
107XX |
1. 5.25-inch External Diskette Drive |
112XX |
1. SCSI Adapter |
119XX |
1. 3119 Adapter |
121XX |
1. Modem Adapter |
136XX |
1. ISDN Primary Rate Adapter |
137XX |
1. System Board |
143XX |
1. Japanese Display Adapter |
14710, 14711 |
1. System Board Display Adapter |
148XX |
1. Display Adapter |
14901, 14902 |
1. Display Adapter |
14932 |
1. External Display |
16101 |
1. Riser Card Battery |
161XX |
1. FaxConcentrator Adapter |
164XX |
1. 120 MB Internal Tape Drive |
16500 |
1. 6157 Tape Attachment Adapter |
16520, 16540 |
1. 6157 Streaming Tape Drive |
166XX, 167XX |
1. Token Ring Adapter |
18001 to 18029 |
1. Wizard Adapter |
18031 to 18039 |
1. Wizard Adapter Cable |
20004 |
1. Memory Module |
206XX |
1. SCSI-2 Adapter |
208XX |
1. Any SCSI Device |
210XX XX 210XXX1 |
1. SCSI Hard Disk Drive |
Tape Drive amber LED remains on. |
1. Tape Drive |
Tape Drive green "in use" LED fails to come on. |
1. Tape Drive |
Tape automatically ejected from drive. |
1. Tape Cassette |
SCSI ID on rotary switch does not match SCSI ID set in configuration. Verify drive switches inside cover are set to zero. |
1. Rotary Switch Circuit Board |
Tape sticks/breaks in drive. |
1. Tape Cassette |
212XX |
1. SCSI Printer |
213XX |
1. SCSI Processor |
214XX |
1. WORM Drive |
215XX XC |
1. CD-ROM Drive I |
216XX |
1. Scanner |
217XX |
1. Rewritable Optical Drive |
218XX |
1. Changer |
219XX |
1. SCSI Device |
27501, 27503 |
1. ServerGuard Adapter |
27502, 27504, 27510 |
1. ServerGuard Adapter |
27509 |
1. Remove redundant adapters, run Auto Configuration program, then retest. |
27512 |
1. WMSELF.DGS diagnostics file missing. |
27535 |
1. 3V Lithium Backup Battery |
27554 |
1. Internal Temperature out of range |
27555, 27556 |
1. ServerGuard Adapter |
27557 |
1. 7.2V NiCad Main Battery Pack |
27558, 27559 |
1. PCMCIA Type II Modem |
27562 |
1. External Power Control not connected |
27563, 27564 |
1. External Power Control |
275XX |
1. Update Diagnostic Software |
27801 to 27879 |
1. Personal Dictation System Adapter |
27880 to 27889 |
1. External FRU (Speaker, Microphone) |
I 99903 0X |
Possible hard disk drive problem, |
Search Keywords |
| |
Hint Category |
Hardware Maintenance Information | |
Date Created |
13-05-96 | |
Last Updated |
30-04-98 | |
Revision Date |
23-04-99 | |
Brand |
IBM PC | |
Product Family |
PC 100, PC 140 | |
Machine Type |
6260, 6271, 6281 | |
Model |
all | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |