7.011 bytes

Service Hints & Tips

Document ID: GSMH-39EAWV

IBM PC Server/IBM PS/2 - SCSI bus termination guidelines

Applicable to: World-Wide

Service Information:
Failure to properly terminate the SCSI Bus can result in poor signal quality and noise on the bus. Errors caused by this condition may be intermittent, and difficult to diagnose. These include difficult to understand Operating System Boot problems and IML failures.
The SCSI Bus is a high-speed bus which has the capability of operating at data rates up to 5/mb per second. Fast SCSI2 specifications push this limit to 10Mb/s and Fast/Wide specifications enable limits upto 20MB/s.
Because of this capability, the bus must be terminated properly at the physical ends of external interface cables. SCSI2 controllers require active termeination to be applied. The terminator resistor networks minimise signal reflections on the bus and insure proper voltage levels.The following SCSI termination schemes may be encountered in the field.
a. SCSI Adapter/A (this adapter has no cache memory). A T-RES Terminator is on the adapter and is described in #4 below
b. SCSI Adapter/A with cache (no onboard terminator). This adapter has no T-RES terminator onboard and is described in #5 below.
c. SCSI Adapter/A with cache (with onboard terminator)

Note:
New Version - automatically substitutes for "b" above. This adapter has a T-RES terminator onboard and is described in #4 below.

d. Integrated SCSI Controller (Part of the system planar). There is a T-RES terminator on the planar and is described in #6 below.

The Following Rules Are a Guide For Proper SCSI Termination:
1. The SCSI Bus must always have a terminator on the device at the physical end of the SCSI bus. These devices include Hardfiles, Tape Drives, CD-ROMDrives etc, and the SCSI Adapter itself, if no devices are connected to one of the interfaces.
2. Terminators are installed only at the ends of the SCSI bus. Terminators which are installed on devices which are not at the end of the bus must be removed from the devices. Failure to do so, will result in excessive current on the SCSI Bus. This can cause early life failure of any attached SCSI device, if operated for extended periods of time. The failure is caused by the Bus Drivers on the SCSI Devices breaking down due to excessive power dissipation.
3. When installing SCSI devices on the internal interface, always attach the device to the last physical connector on the cable.
4. For the IBM PS/2 SCSI Adapter/A with the onboard T-RES Module (Terminator). Termination of the adapter is accomplished when the 20 pin T-RESModule is in its socket (this module is usually orange or yellow in colour). The T-RES module needs to be removed from the adapter if both internal and external devices are attached to the adapter. In this situation, the SCSI bus is terminated at the last device on both the internal and external cables.
5. For the IBM PS/2 SCSI Adapter/A (W/Cache) which does not have an onboard T-RES Module. Termination of the adapter is done in one of the following three ways:
a. only external devices are connected to the adapter, attach the internal terminator to the edge card connector on top of the adapter and terminate the last device on the external SCSI cable
b. only internal devices are connected to the adapter, attach the external terminator plug to the connector at the rear of the adapter and terminate the last device on the internal SCSI cable.
c. both internal and external devices are connected, termination is done on the last device on the internal cable and termination is done on the last device on the external cable.
6. For the SCSI Controller which is built into the System Planar, there is also a T-RES Module (Terminator) on the System Planar (refer to the HMR manual for exact location). The termination of the SCSI bus is accomplished when the 20 pin T-RES module is in its socket (This module is usually orange in colour). The T-RES Module needs to be removed from the Planar if both internal and external devices are attached to the controller. In this situation, the SCSI Bus is terminated at the last device on the internal cable and the last device on the external cable,

Note:
The following publication is available by ordering GG24-4002-00: "IBM PS/2 and PS/Valuepoint Subsystems." This book provides valuable information about SCSI and XGA-II Subsystems and supersedes earlier document: "SCSI Architecture and Implementation".

SAS KEYWORDS:
PSY2 PSY2FDSK PSY2ADPT 8550SYSFDSK
8557SYSFDSK 8560SYSFDSK 8565SYSFDSK 8570SYSFDSK
8580SYSFDSK 8590SYSFDSK 8595SYSFDSK 8550SYSADPT
8557SYSADPT 8560SYSADPT 8565SYSADPT 8570SYSADPT
8580SYSADPT 8590SYSADPT 8595SYSADPT D/T8557
D/T8555 D/T8560 D/T8565 D/T8570
D/T8573 D/T8580 D/T8590 D/T8595
D/T8556 D/T8556SYSFDSK 8556SYSADPT D/T9595
D/T9590 D/T9585 D/T9576 D/T9577
D/T9556 D/T9557 PSVP D/T6382
D/T6384 D/T6387

Search Keywords

Hint Category

Retain, SCSI

Date Created

12-12-91

Last Updated

07-05-98

Revision Date

27-04-99

Brand

IBM PC

Product Family

PS/2

Machine Type

8555, 8556, 8560, 8565, 8570, 8573, 8580, 8590, 8595, 9556, 9557, 9576, 9577

Model

Various

TypeModel

Retain Tip (if applicable)

H092645

Reverse Doclinks
and Admin Purposes