6.856 bytes

Product Information

Document ID: MCGN-43VRL7

Netfinity 5000 - Diagnostic Error Codes

Applicable to: World-Wide

Diagnostic Error Codes

Attention
In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU.
The description for these error codes are:

000 The test passed.
195 The Esc key was pressed to abort the test.
197 This a warning error and may not indicate a hardware failure.

For all other error codes, replace/follow the FRU/Action indicated.


Error Code/Symptom

FRU/Action

001-XXX-000
(Failed core tests)

1. System Board

005-XXX-000
(Failed Video test)

1. System Board

011-XXX-000
(Failed COM1 Serial Port test)

1. System Board

011-XXX-001
(Failed COM2 Serial Port test)

1. System Board

014-XXX-000
(Failed Parallel Port test)

1. System Board

015-XXX-001
(Failed USB test)

1. System Board

020-XXX-000
(Failed PCI Interface test)

1. System Board

075-XXX-000
(Failed Power Supply test)

1. Power Supply

089-XXX-001
(Failed Microprocessor test)

1. Microprocessor
2. System Board

089-XXX-002
(Failed Optional Microprocessor test)

1. Optional Microprocessor
2. VRM for Optional Microprocessor

165-XXX-000
(Failed System Board test)

1. System Board
2. Hot-Swap Drive Backplane

180-XXX-001
(Failed Information Panel LED test)

1. Information LED Panel
2. Power-on Panel

180-XXX-003
(Failed System Board LED test)

1. System Board

180-XXX-005
(Failed SCSI Backplane LED test)

1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board

201-XXX-001
(Failed Memory test )

1. DIMM Location J15

201-XXX-002
(Failed Memory test )

1. DIMM Location J16

201-XXX-003
(Failed Memory test )

1. DIMM Location J17

201-XXX-004
(Failed Memory test )

1. DIMM Location J22

201-XXX-999
(Multiple DIMM failure, see error text.)

1. See error text for failing DIMMs

202-XXX-001
(Failed System Cache test)

1. Microprocessor

202-XXX-002
(Failed System Cache test on Optional Microprocessor)

1. Optional Microprocessor

206-XXX-000
(Failed Diskette Drive test)

1. Diskette Drive cable
2. Diskette Drive

215-XXX-000
(Failed IDE test)

1. System Board

217-XXX-000
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
RAID logical drive.

1. Fixed Disk 1

217-XXX-001
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive.

1. Fixed Disk 2

217-XXX-002
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive.

1. Fixed Disk 3

217-XXX-003
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive.

1. Fixed Disk 4

217-XXX-004
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive.

1. Fixed Disk 5

217-XXX-005
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive.

1. Fixed Disk 6

301-XXX-000
(Failed Keyboard test)

1. Keyboard

405-XXX-000
(Failed Ethernet test)

1. System Board