5.174 bytes

Product Information

Document ID: DDSE-42TM4T

Netfinity 5500 - Control Panel System Error LED

Applicable to: World-Wide

Control Panel System Error LED
The system error LED is turned on when an error is detected. If the system error LED is on, remove the cover and check the diagnostic panel LEDs. The following is a complete list of diagnostic panel LEDs followed by the FRU/Action for replacing the problem.

Notes
1. To locate the LEDs on the processor board see "Processor Board Component Locations".
2. To locate the LEDs on the system board see "System Board Component Locations".
3. Check the system error log for additional information before replacing a FRU.




Diagnostic Panel LED

FRU/Action

CPU LED on
(The LED next to the failing CPU is on.)

1. Processor 1 or 2 on (Processor 1 or 2).
2. Processor Board

DASD 1 LED on
(The LED located next to the drive bay that
the failing drive is installed in will be
turned on.)

1. Failing drive.
2. Be sure the fans are operating correctly and
the air flow is good.
3. SCSI Backplane

FAN 1 LED on

1. Fan 1
2. Fan Cable
3. System Board

FAN 2 LED on

1. Fan 2
2. Fan Cable
3. System Board

FAN 3 LED on

1. Fan 3
2. Fan Cable
3. System Board

MEM LED on
(The LED next to the failing DIMM is on.)

1. Failing DIMM in slot J1, J2, J3, or J4).
2. System Board
3. Processor Board

NMI LED on
(Machine check error)

1. Reboot the system.
2. Check the system Board LED(s); if on,
see "System Board LEDs".
3. Check the system error log.

PCI 1 LED on

1. PCI Card for the PCI slot LED that is
turned on
2. System Board
3. Processor Board

PCI 2 LED on

1. Card in slot 1 or 4
2. System Board
3. Processor Board

PS1 LED on

1. Check the DC Good LED on power supply 1.
If off, replace power supply 1.
2. Power Backplane

PS2 LED on

1. Check the DC Good LED on power supply 2.
If off, replace power supply 2.
2. Power Backplane

SMI LED on

1. Reboot the system.
2. Check the system Board LED(s); if on,
see "System Board LEDs".

TEMP LED on

1. Be sure the fans are operating correctly and
the air flow is good.
2. Check processor 1 and 2 LEDs
3. Be sure the power supply fans are operating
correctly and the air flow is good.
4. Processor Board
5. System Board

VRM LED on
(Check the VRM (voltage regulator module)
LEDs on the processor board.)

1. Voltage regulator module for the VRM LED
on the processor board that is turned on
2. Processor 1, if the VRM 1 LED on the
processor board is on. Processor 2, if the
VRM 2 LED on the processor board is on.
3. Processor Board



Search Keywords

Document Category

Diagnostics

Date Created

03-12-98

Last Updated

03-12-98

Revision Date

03-12-99

Brand

IBM PC Server

Product Family

Netfinity 5500

Machine Type

8660

Model

ALL

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes