Error Code/Symptom |
FRU/Action |
001-XXX-000
(Failed core tests) |
1. System Board |
001-XXX-001
(Failed core tests) |
1. Processor Board |
005-XXX-000
(Failed Video test) |
1. System Board
2. Processor Board |
011-XXX-000
(Failed COM1 Serial Port test) |
1. System Board |
011-XXX-001
(Failed COM2 Serial Port test) |
1. System Board |
014-XXX-000
(Failed Parallel Port test) |
1. System Board |
015-XXX-001
(Failed USB test) |
1. System Board |
020-XXX-000
(Failed PCI Interface test) |
1. Processor Board
2. System Board |
020-XXX-001
(Failed Hot Swap Slot 1 PCI Latch test) |
1. PCI Hot Swap Latch Assembly
2. System Board |
020-XXX-002
(Failed Hot Swap Slot 2 PCI Latch test) |
1. PCI Hot Swap Latch Assembly
2. System Board |
020-XXX-003
(Failed Hot Swap Slot 3 PCI Latch test) |
1. PCI Hot Swap Latch Assembly
2. System Board |
020-XXX-004
(Failed Hot Swap Slot 4 PCI Latch test) |
1. PCI Hot Swap Latch Assembly
2. System Board |
030-XXX-000
(Failed Internal SCSI interface test) |
1. System Board |
035-XXX-000
DUPLICATE ERROR CODE
(Failed System Board RAID test. Check System Error Log before replacing a FRU.) |
1. Verify RAID adapter disable jumper block
is not installed (see "System board jumpers").
2. System Board
3. SCSI Backplane
4. Cable |
035-XXX-000
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.) |
1. Fixed Disk with SCSI ID 00 on System Board RAID controller |
035-XXX-0NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) |
1. Fixed Disk with SCSI ID NN on System Board RAID controller |
035-XXX-100
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 1. Check System Error Log before replacing a FRU.) |
1. Adapter
2. SCSI Backplane
3. Cable |
035-XXX-100
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.) |
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 1 |
035-XXX-1NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) |
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 1 |
035-XXX-200
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 2. Check System Error Log before replacing a FRU.) |
1. Adapter
2. SCSI Backplane
3. Cable |
035-XXX-200
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.) |
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 2 |
035-XXX-2NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) |
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 2 |
035-XXX-300
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 3. Check System Error Log before replacing a FRU.) |
1. Adapter
2. SCSI Backplane
3. Cable
|
035-XXX-300
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.) |
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 3 |
035-XXX-3NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) |
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 3 |
035-XXX-400
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 4. Check System Error Log before replacing a FRU.) |
1. Adapter
2. SCSI Backplane
3. Cable |
035-XXX-400
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.) |
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 4 |
035-XXX-4NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) |
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 4 |
035-XXX-500
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 5. Check System Error Log before replacing a FRU.) |
1. Adapter
2. SCSI Backplane
3. Cable |
035-XXX-500
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.) |
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 5 |
035-XXX-5NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) |
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 5 |
075-XXX-000
(Failed Power Supply test) |
1. Power Supply |
089-XXX-001
(Failed Microprocessor test) |
1. VRM 1 or VRM 2
2. Microprocessor CPU 1 |
089-XXX-002
(Failed Microprocessor test) |
1. VRM 3 or VRM 2
2. Microprocessor CPU 2 |
089-XXX-003
(Failed Microprocessor test) |
1. VRM 4 or VRM 5
2. Microprocessor CPU 3 |
089-XXX-004
(Failed Microprocessor test) |
1. VRM 6 or VRM 5
2. Microprocessor CPU 4 |
165-XXX-000
(Failed System Board test) |
1. System Board
Before replacing the system board, ensure that system board jumper J51 is not installed (the default) when the error occurs.
2. Processor Board
3. Power Backplane
4. Hot-Swap Drive Backplane |
180-XXX-000
(Diagnostics LED failure) |
1. Run Diagnostic LED test for the failing LED |
180-XXX-001
(Failed Information LED panel test) |
1. Information LED Panel
2. Power Switch Assembly |
180-XXX-002
(Failed Diagnostics LED Panel test) |
1. Diagnostics LED Panel
2. Power Switch Assembly |
180-XXX-003
(Failed System Board LED test) |
1. Run hot-swap PCI latch test in Other Devices
under Extended Tests
2. System Board |
180-XXX-004
(Failed Processor Board LED test) |
1. Processor Board
2. System Board |
180-XXX-005
(Failed SCSI Backplane LED test) |
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board |
201-XXX-001
(Failed Memory test, see "Memory Settings") |
1. DIMM Location J1
|
201-XXX-002
(Failed Memory test, see "Memory Settings" ) |
1. DIMM Location J2
|
201-XXX-003
(Failed Memory test, see "Memory Settings" ) |
1. DIMM Location J3
|
201-XXX-004
(Failed Memory test, see "Memory Settings" ) |
1. DIMM Location J4
|
201-XXX-005
(Failed Memory test, see "Memory settings" ) |
1. DIMM Location J5 |
201-XXX-006
(Failed Memory test, see "Memory settings" ) |
1. DIMM Location J6 |
201-XXX-007
(Failed Memory test, see "Memory settings" ) |
1. DIMM Location J7 |
201-XXX-008
(Failed Memory test, see "Memory settings" ) |
1. DIMM Location J8 |
201-XXX-999
(Multiple DIMM failure, see error text.) |
1. See error text for failing DIMMs |
202-XXX-001
(Failed System Cache test) |
1. VRM 2 or VRM 1
2. Microprocessor CPU 1 |
202-XXX-002
(Failed System Cache test) |
1. VRM 2 or VRM 3
2. Microprocessor CPU 2 |
202-XXX-003
(Failed System Cache test) |
1. VRM 5 or VRM 4
2. Microprocessor CPU 3 |
202-XXX-004
(Failed System Cache test) |
1. VRM 5 or VRM 6
2. Microprocessor CPU 4 |
206-XXX-000
(Failed Diskette Drive test) |
1. Cable
2. Diskette Drive
3. System Board |
215-XXX-000
(Failed IDE CD-ROM test)
|
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board |
217-XXX-000
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive. |
1. Fixed Disk 1 |
217-XXX-001
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive. |
1. Fixed Disk 2 |
217-XXX-002
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive. |
1. Fixed Disk 3 |
217-XXX-003
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive. |
1. Fixed Disk 4 |
217-XXX-004
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the RAID
logical drive. |
1. Fixed Disk 5 |
217-XXX-005
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive. |
1. Fixed Disk 6 |
264-XXX-0NN
(Failed Tape Drive test) |
1. Tape cartridge, if user executed the Read/Write Tape Drive test (XXX=256).
2. SCSI or power cable connected to the tape drive with SCSI ID NN.
3. Tape drive with SCSI ID NN.
4. System board or SCSI Controller (Run SCSI Contoller Diagnostic to determine if the SCSI bus is functioning properly.) |
264-XXX-999
(Errors on muliple tape drives, see error text for more info) |
1. See error messages/text in the error log for
detailed information on each individual tape drive error. |
301-XXX-000
(Failed Keyboard test) |
1. Keyboard |
405-XXX-000
(Failed Ethernet test on controller on the system board) |
1. Verify that the ethernet disable jumper is not
installed (see "System board jumpers").
2. System Board |
405-XXX-00N
(Failed Ethernet test on adapter in PCI slot N) |
1. Adapter in PCI slot N
2. System Board |
415-XXX-000
(Failed Modem test) |
1. Cable
2. Modem
3. System Board |