10.689 bytes

Service Hints & Tips

Document ID: GSMH-3EXMF6

PC Server 325 - Error codes

Applicable to: World-Wide

Error Codes:
In the following error codes,X can be any number or letter.

Error Code/Symptom

FRU/Action

E100, E101
(Invalid EISA configuration)

1. Run EISA Configuration
2. Failing EISA adapter
3. Real-Time Clock with Battery
4. System Board

E10X
(Invalid EISA configuration for Slot X)

1. Run EISA Configuration
2. Failing EISA adapter in slot X

101, 102 (System and microprocessor error)

1. System Board
2. Microprocessor Board

106 (System and microprocessor error)

1. System Board
2. Microprocessor Board

111
(I/O channel check error)

1. Failing EISA/ISA Adapter
2. Memory DIMM
3. System Board

114
(Adapter read-only memory error)

1. Failing Adapter
2. Run Diagnostics

129
(Internal Cache error)

1. Optional Microprocessor
(if installed)
2. Microprocessor
3. Microprocessor Board

151
(Real time clock error)

1. Run Diagnostics
2. Real-Time Clock with Battery
3. System Board

162
(Device Configuration Error)

1. Run Configuration/Setup; then, run the EISA Configuration Utility
2. Failing Device
3. Real-Time Clock with Battery
4. System Board

163
(Real-Time Clock error)

1. Run Configuration/Setup
2. Real-Time Clock with Battery
3. System Board

164
(Memory configuration changed)

1. Run Configuration/Setup
2. DIMM
3. Microprocessor Board

173
(System CMOS checksum bad)

1. Run Configuration/Setup
2. Real-Time Clock with Battery
3. System Board

175
(Hardware error)

1. System board
2. Microprocessor Board

176
(Computer cover or cable cover was removed without a key being used)

1. Run Configuration/Setup

177, 178
(Security hardware error)

1. Run Configuration/Setup
2. System Board

182
(System board error)

1. System board

183
(Administration password not entered)

1. System board

184
(Power-on password corrupted)

1. Run Configuration/Setup
2. System board

185
(Drive startup sequence information corrupted)

1. Run Configuration/Setup
2. System board

186
(System board or security hardware error)

1. Run Configuration/Setup
2. System Board

187
(System board or security hardware error)

1. System board

188
(System board or security hardware error)

1. System board

189
(An attempt was made to access the server with invalid passwords)

1. Run Configuration/Setup, enter the administrator password

201 (Memory test error)

1. DIMM
2. Processor Board
3. System Board

229
(Cache error)

1. Optional Microprocessor
(if installed)
2. Microprocessor
3. Microprocessor Board

301
(Keyboard or keyboard controller error)

1. Keyboard
2. System Board

604
(Diskette drive error)

1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board

605
(Diskette Unlock failure)

1. Diskette Drive
2. Drive Cable
3. System Board

662
(Diskette drive configuration error)

1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board

962
(Parallel port error)

1. Disconnect external cable on parallel port
2. Run Configuration/Setup
3. System Board

11XX (System-board serial port 1 or 2 error)

1. Disconnect external cable on serial port
2. Run Configuration/Setup
3. System board

1762
(Fixed Disk Configuration error)

1. Fixed Disk Cables
2. Run Configuration/Setup
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. System Board

178X
(Fixed Disk error)

1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. System Board

1800
(No more hardware interrupt available for PCI adapter)

1. Run Configuration/Setup
2. Run EISA Configuration
3. Failing Adapter
4. System Board

1801
(No room for PCI option ROM)

1. Run Configuration/Setup
2. Run EISA Configuration
3. Failing Adapter
4. System Board

1802
(No more I/O space available for PCI adapter)

1. Run Configuration/Setup
2. Failing Adapter
3. System Board

1803
(No more memory (above 1 MB for PCI adapter)

1. Run Configuration/Setup
2. Failing Adapter
3. System Board

1804
(No more memory (below 1 MB for PCI adapter)

1. Run Configuration/Setup
2. Move failing adapter to slot 1 or 2
3. Failing Adapter
4. System Board

1805
(PCI option ROM checksum error)

1. Remove Failing PCI Card
2. System Board

1806
(PCI to PCI Bridge error)

1. Run Configuration/Setup
2. Move failing adapter to slot 1 or 2
3. Failing Adapter
4. System Board

2400
(Video controller test failure)

1. Video Adapter (if installed)
2. System Board

2462
(Video memory configuration error)

1. Video Adapter
(if installed)
2. System Board

8603
(Pointing Device Error)

1. Pointing Device
2. System Board

I9990301
(Fixed boot sector error, no operating system installed)

1. Run Configuration/Setup for correct startup
2. Verify operating system installed

I9990305
(Fixed boot sector error, no operating system installed)

1. Install operating system to hard disk drive



Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

07-03-97

Last Updated

31-07-98

Revision Date

30-07-99

Brand

IBM PC Server

Product Family

PC Server 325

Machine Type

8639

Model

EJ0; ES0; ESV; RD0; RF0; RS0; XD0; XDV; XF0; XFV; XJ0; XS0; XSV; YS0

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes