Size (Tower Model)
Depth: 718 mm (28.3 in.)
Height: 555 mm (21.9 in.)
Width: 483 mm (19.1 in.)
Front clearance: 305 mm (12.0 in.)
Rear clearance: 127 mm (5.0 in.)
Side clearance: 76 mm (3.0 in.)

Size (Rack Model)
Depth: 673 mm (26.5 in.)
Height: 484 mm (19.1 in.) (approximately 11 EIA Units)
Width: 437 mm (17.2 in.) (482 mm with mounting flanges)

Weight
Unpacked, minimum configuration:
54.5 kg (120 lb.)
Unpacked, maximum configuration:
72.6 kg (160 lb.)

Electrical Input
Sine-wave input (50 to 60 Hz) is required
Input voltage
Low range
- Minimum: 90 V ac
- Maximum: 137 V ac
High range
- Minimum: 180 V ac
- Maximum: 265 V ac
Input kilovolt-amperes (KVA) approximately
- Minimum configuration as shipped: 0.2 KVA
- Maximum configuration: 0.78 KVA

Environment
Air temperature
System on: 0› to 35› C
(0› to 95› F)
Altitude: 0 to 914 m (3000 ft.)
System on: 0› to 32› C
(0› to 89.6› F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
System off: 10› to 43› C
(50› to 110› F)
Maximum altitude: 2133 m (7000 ft.)
Humidity
System on:
8% to 80%; maximum wetbulb
23› C (73.4› F)
System off:
8% to 80%; maximum wetbulb 27› C (80.6› F)

Altitude: 0 to 2133 m (0 to 7000 ft.)

Electrostatic Discharge
Tested to 20 KV

Immunity
Verified to comply with EN 50082-2

Sound
Sound Power, idling:
- 6.2 bel for open bay system (no hard drives installed)
- 6.3 bel for typical system configuration (1 bay filled with hard drives)
Sound Power, operating:
- 6.2 bel for open bay system (no hard drives installed)
- 6.4 bel for typical system configuration (1 bay filled with hard drives)
Sound Pressure, idling:
- 46 dBA for open bay system (no hard drives installed)
- 46 dBA for typical system configuration (1 bay filled with hard drives)
Sound Pressure, operating:
- 46 dBA for open bay system (no hard drives installed)
- 47 dBA for typical system configuration (1 bay filled with hard drives)

These levels are measured in controlled acoustical environments according to ISO 7779 and are reported in accordance with ISO 9296. The declared sound power levels indicate an upper limit, below which a large portion of machines operate. Sound pressure levels in your location might exceed the average 1-meter values stated because of room reflections and other nearby noise.

Heat Output
Approximate heat output in British thermal units (BTU) per hour:
Minimum configuration: 1023.9 BTU
Maximum configuration: 2764.6 BTU

Safety Standards
UL 1950
CSA C22.2 No. 950-M93
EN 60950 and countries deviations
IEC 950
NOM-019

Search Keywords

Document Category

Technical Specifications

Date Created

03-12-98

Last Updated

03-12-98

Revision Date

03-12-99

Brand

IBM PC Server

Product Family

Netfinity 7000

Machine Type

8651

Model

ALL

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes