2.412 bytes |
Service Hints & Tips |
Document ID: JBAR-3W8RRQ |
IBM IntelliStation/IBM PC - On/Off power button sticks
Applicable to: World-Wide, World-Wide
SYMPTOM:
When pressing the white ON/OFF button on the front of the system unit, the button sticks, or binds in the depressed position.
PROBLEM ISOLATION AIDS:
This tip applies to the following systems:
IBM PC300PL Series 6862
IBM PC300GL Series 6275
IBM PC300GL Series 6561
IBM IntelliStation E Pro Series 6893
FIX:
Verify that the top cover assembly is fully seated towards the rear of the system unit.
If the sticking condition persists, replace the top cover assembly with the appropriate FRU part number.
IBM PC300PL Series 6862 |
FRU P/N 01K1607 |
IBM PC300GL Series 6275 |
FRU P/N 01K1607 |
IBM PC300GL Series 6561 |
FRU P/N 01K1607 |
IBM IntelliStation E Pro Series 6893 |
FRU P/N 02K2731 |
SAS KEYWORDS:
PSY2 PSY2PART CDT CDTPART
PWS PWSPART D/T6862 D/T6275
D/T6561 D/T6893 SWITCH 01K1607
02K2731 UNCLASSIFIED