20.359 bytes |
Service Hints & Tips |
Document ID: MCGN-3VWSRY |
Servers - ECA022: Firmware upgrade for some 4.5 / 9.1GB SCSI hard drives
Applicable to: World-Wide
PURPOSE:
This ECA is MANDATORY and replaces the previous ECA016. This ECA provides for a Microcode upgrade on the following IBM SCSI hard drives:
4.5 GB 80-Pin SCSI Hard Disk Drive (FRU p/n76H5817)
4.5 GB 80-Pin SCSI Hard Disk Drive (FRU p/n01K6675)
9.1 GB 80-Pin SCSI Hard Disk Drive (FRU p/n76H5818)
9.1 GB 80-Pin SCSI Hard Disk Drive (FRU p/n01K6679)
4.5 GB 68-Pin SCSI Hard Disk Drive (FRU p/n76H2697)
4.5 GB 68-Pin SCSI Hard Disk Drive (FRU p/n93G2970)
9.1 GB 68-Pin SCSI Hard Disk Drive (FRU p/n76H2698)
9.1 GB 68-Pin SCSI Hard Disk Drive (FRU p/n93G2972)
4.5 GB 50-Pin SCSI Hard Disk Drive (FRU p/n76H2695)
9.1 GB 50-Pin SCSI Hard Disk Drive (FRU p/n76H2696)
The Microcode will upgrade these hard drives when attached to the following Adapters / Controllers:
Utility Menu | ||
ServeRAID Adapter |
FRU p/n06H9334 |
2 or 3 |
ServeRAID Adapter |
FRU p/n76H6875 |
2 or 3 |
ServeRAID II Adapter |
FRU p/n76H3587 |
2 or 3 |
Onboard ServeRAID II Controller |
(integrated) |
2 or 3 |
PCI SCSI-2 F/W Adapter |
FRU p/n06H6473 |
1 |
PCI SCSI-2 F/W Adapter II |
FRU p/n06H8574 |
1 |
PCI SCSI-2 U/W Adapter |
FRU p/n60H7823 |
1 |
PCI SCSI-2 F/W Controller |
(Integrated) |
1 |
PCI SCSI-2 U/W Controller |
(Integrated) |
1 |
Servers eligible for this ECA may exhibit hard drive read errors on the hard drives specific to this ECA and/or may experience degradation of RAID disk subsystem performance due to read errors on the drives specific to this ECA and/or may experience defunct drives (DDD) on the hard drives specific to this ECA. Drives may be located in the Server or Type 3517,3518,3519,3520 enclosure attached to the IBM PC Server / IBM Netfinity server. This ECA is "MANDATORY". This ECA will expire on January 1, 2003.
FEATURES:
Type, |
With |
Machines Affected |
B/M to be |
Service |
System |
8638 |
B/M0000000 |
USA: |
B/M0000000 |
00.5 |
00.3 |
8639 |
B/M0000000 |
PC SERVER 310 |
B/M0000000 |
00.5 |
00.3 |
8639 |
B/M0000000 |
PC SERVER 325 |
B/M0000000 |
00.5 |
00.3 |
8640 |
B/M0000000 |
PC SERVER 320 |
B/M0000000 |
00.5 |
00.3 |
8640 |
B/M0000000 |
PC SERVER 330 |
B/M0000000 |
00.5 |
00.3 |
8641 |
B/M0000000 |
PC SERVER 500 |
B/M0000000 |
00.5 |
00.3 |
8641 |
B/M0000000 |
PC SERVER 520 |
B/M0000000 |
00.5 |
00.3 |
8642 |
B/M0000000 |
PC SERVER 720 |
B/M0000000 |
00.5 |
00.3 |
8650 |
B/M0000000 |
PC SERVER 704 |
B/M0000000 |
00.5 |
00.3 |
8476 |
B/M0000000 |
NETFINITY 3000 SERVER |
B/M0000000 |
00.5 |
00.3 |
8644 |
B/M0000000 |
NETFINITY 3500 SERVER |
B/M0000000 |
00.5 |
00.3 |
8660 |
B/M0000000 |
NETFINITY 5500 SERVER |
B/M0000000 |
00.5 |
00.3 |
8651 |
B/M0000000 |
NETFINITY 7000 SERVER |
B/M0000000 |
00.5 |
00.3 |
PHYSICAL CHECK:
- Determine which SCSI Adapter(s)/Controller is present in the PC Server/Netfinity server (the Microcode Update will prompt for a SCSI Adapter/Controller selection when it is booted).
- If a Type 3517, 3518, 3519, 3520 external storage enclosure is attached to the PC Server / Netfinity server, ensure that it is connected securely to the appropriate SCSI Port, and Powered On.
Note: Refer to the Adapter List in this Document for FRU p/n's of Adapters the Update Utility supports.
*********IMPORTANT*********IMPORTANT*********IMPORTANT*********
- DO NOT FLASH HARD DRIVES WITH THE OLDER VERSION 1.03 OF THE UPDATE UTILITY.
- IMPORTANT: FLASHING DRIVES WITH VER 1.03 TO THE FOLLOWING ADAPTERS CAN CAUSE DRIVES TO GO DDD.
- AS SUCH WE HAVE DETERMINED YOU NO LONGER NEED TO FLASH DRIVES ON THE FOLLOWING ADAPTERS. IN VER 1.04, THE OPTIONS TO FLASH DRIVES CONNECTED TO THESE ADAPTERS HAS BEEN REMOVED.
DAC 960 PL F/W RAID Adapter |
FRU p/n75H9011 |
Micro Channel RAID Adapter |
FRU p/n06H3059 |
Micro Channel SCSI-2 F/W /A |
FRU p/n92F0160 |
PCI RAID Adapter |
FRU p/n06H5078 |
***************************************************************
PREREQUISITES:
To Install |
ECA |
EC |
Physical Check |
B/M0000000 |
ECA000 |
EC000000 |
NONE |
To Install |
ECA |
Machine |
Comments |
B/M0000000 |
ECA012 |
0000 |
THE UPDATE UTILITY |
To Install |
ECA |
Machine |
Comments |
B/M0000000 |
ECA000 |
0000 |
RETAIN RECORD# H162302 |
DETAIL:
Prior to going onsite, download the following diskette images (keep for future use to implement this ECA):
"PC Server and Netfinity server 4.5GB - 9.1GB Hard Drive Update Diskette V1.04"
(a bootable diskette that contains the Microcode Update Utility for all Adapters listed in this document).
"IBM ServeRAID and IBM ServeRAID II Supplemental Diskette version 2.41" or later (a non-bootable diskette containing the Network Operating System-specific IPSSEND utilities for use with all ServeRAID II Adapters / Controllers). These Diskette images may be downloaded from the following URL:
http://www.pc.ibm.com/us/files.html
- Select "Search"
- Type "9.1GB" or "ServeRAID Supplemental" to locate each of the above diskette images.
- Select the file (by the above description(s) to download.
- These are self-extracting executable files that prompt for one diskette each.
Note: It is recommended that the readme file is printed out for reference when using these diskettes.
********************* IMPORTANT ********************************
PRIOR to updating the Microcode on any hard drives attached to a ServeRAID II Adapter or Onboard ServeRAID II Controller, check if Autosynch is running. DO NOT apply the Microcode update if Autosynch is running, wait for Autosynch to complete prior to applying the Microcode. Use EITHER of the following procedures to determine the state of Autosynch on a ServeRAID II Adapter or Onboard ServeRAID II Controller:
With the Server up and running:
1- Place the "IBM ServeRAID and IBM ServeRAID II Supplemental Diskette version 2.41" or later in the floppy drive (drive A:)
2- From a Operating System Command prompt, go to the directory in drive A: (relative to Operating System) and type the following command line:
IPSSEND GETSTATUS X (then press <enter>)
(where X is the Adapter number, example: 1,2,3, or 4)
This will result with the following information displayed:
"Current / Most Recent Operation : = xxxxxxxxx
"Status" : = xxxxxxxxx
Example of Autosynch running:
"Current / Most Recent Operation : = Synchronize
"Status" : = In Progress
Example of Autosynch completed:
"Current / Most Recent Operation : = Synchronize
"Status" : = Completed
Note: The status displayed is that when the IPSSEND command was issued. The command may need to be re-issued to see any status changes.
DO NOT Start the Microcode Update until the Synchronize Operation is completed.
---------------------- OR ---------------------------------
With the Server down and Powered-Off:
The Microcode Update Utility will automatically check to see if the Autosynch is running. If it is running, it will return a message indicating Autosynch is running and to run the Update after it has completed. To run this Utility, proceed to the next section.
Note:
DO NOT Start the Microcode Update until the Synchronize Operation is completed.
****************************************************************
UPDATING THE MICROCODE ON THE HARD DRIVES:
The Microcode update is executed from the "PC Server and Netfinity server 4.5GB - 9.1GB Hard Drive Update Diskette V1.04".
This diskette is bootable. Upon boot, it will prompt for the user to select from a list of SCSI adapters to load the respective driver (see the "Utility Menu selection #" column in the Adapter / Controller List for proper Adapter selection). When the driver loads, the Adapter / Controller will initialize and then the utility will search for the SCSI hard drives specific to this ECA. If found, the drive(s) Firmware will be flashed to a new Microcode level (level 64) which fixes the Read error / DDD status issue.
NOTE: DO NOT power off the PC Server / Netfinity server or any attached type 3517, 3518, 3519, 3520 enclosure while the Update Utility is running.
NOTE: If there are multiple SCSI adapters in the system that are identical, it will not be necessary to run the update utility for each adapter.
NOTE: If there are multiple SCSI adapters of different types, then the Update Utility needs to be executed more than one time since the correct driver must be selected at boot time. The adapters are different and will respond to their respective drivers.
NOTES:
This ECA is MANDATORY.
This ECA will expire on January 1, 2003.
IBM/TSS CE's should record all time to Service Code 33, ECA022, other office 990.
EMEA Dealers: claim as type 5, referencing CPPS ECA Codes:
Machine Type 8638 = SN
" 8639 = SO
" 8640 = SP
" 8641 = SR
" 8642 = ST
" 8650 = SU
" 8651 = SV
" 8644 = SW
" 8660 = SX
" 8476 = SY
SAS KEYWORDS:
PSY2, UNCLASSIFIED, D/T8638, D/T8640, D/T8641, D/T8642, D/T8650, D/T8651, MICROCODE, 4.5GB, 9.1GB, H162302, ECA016, ECA012, HEALTH, D/T3518, D/T8476, D/T8660, D/T8644, ECA022, D/T3517, D/T3518, D/T3520, DASD, DRIVES, READ, ERROR, DDD, H164048
Search Keywords |
| |
Hint Category |
ECA, Retain | |
Date Created |
29-06-98 | |
Last Updated |
31-08-98 | |
Revision Date |
27-08-99 | |
Brand |
IBM PC Server | |
Product Family |
Netfinity 3000, Netfinity 3500, Netfinity 5500, Netfinity 7000, PC Server 310, PC Server 315, PC Server 320, PC Server 325, PC Server 330, PC Server 500, PC Server 520, PC Server 704, PC Server 720, Rack/Storage Enclosures | |
Machine Type |
8476, 8644, 8660, 8651, 8639, 8638, 8640, 8641, 8650, 8642 | |
Model |
Various | |
TypeModel |
| |
Retain Tip (if applicable) |
H164048, ECA022 | |
Reverse Doclinks |
Date last altered: A98/08/21 |