Error Code/Symptom |
FRU/Action |
062
(Three consecutive boot failures using the default configuration.) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card |
101, 102
(System and processor error) |
1. I/O Board
2. Processor Board |
106
(Diskette controller error) |
1. I/O Function Card
2. I/O Board |
111
(Channel check error) |
1. I/O Board |
114
(Adapter read-only memory error) |
1. Failing Adapter
2. Run Diagnostics |
129
(Internal Cache error) |
1. BSP Processor
2. Processor Board |
151
(Real time clock error) |
1. Run Diagnostics
2. Battery, see "Battery"
3. I/O Function Card |
161
(Real time clock battery error) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card |
162
(Device Configuration Error)
Important
Be sure to load the default settings and any additional desired settings; then, save the configuration. |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. Failing Device
4. I/O Board |
163
(Real-Time Clock error) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card |
164
(Memory configuration changed) |
1. If error 289 is displayed, follow instruction on screen.
Verify failing FRU in system error log.
2. Run Configuration/Setup
3. Memory Card
4. Processor Board |
173
(System CMOS checksum bad) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card |
175
(Hardware error) |
1. I/O Board
2. Processor Board
3. System Management Card |
176
(Computer cover or cable cover was removed without
a key being used) |
1. Run Configuration/Setup
2. Intrusion (C2 Security) Cable
3. Front Panel
4. I/O Function Card |
177, 178
(Security hardware error) |
1. Run Configuration/Setup
2. System Management Card
3. Front Panel |
184
(Power-on password corrupted) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. System Management Card |
185
(Drive startup sequence information corrupted) |
1. Run Configuration/Setup
2. System Management Card |
186
(Security control logic error) |
1. Run Configuration/Setup
2. System Management Card
3. Front Panel |
187
(VPD serial number not set.) |
1. Set serial number in Setup
2. System Management Card |
188
(Bad EEPROM CRC #2) |
1. Run Configuration/Setup
2. I/O Board |
189
(An attempt was made to access the server with invalid passwords) |
1. Run Configuration/Setup, enter the administrator
password |
201
(Memory test error) |
1. DIMM
2. Memory Board
3. Processor Board |
229
(Cache error) |
1. BSP Processor
2. Processor Board |
262
(DRAM parity configuration error) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. Processor Board |
289
(DIMM has been disabled by the user or system) |
1. Follow the instructions on the screen. Verify the failing
FRU in the system error log. |
301
(Keyboard or keyboard controller error) |
1. Keyboard
2. I/O Function Card
3. I/O Board |
303
(Keyboard controller error) |
1. Keyboard
2. I/O Function Card
3. I/O Board |
602
(Invalid diskette boot record) |
1. Diskette
2. Cable
3. Diskette Drive |
604
(Diskette drive error) |
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Function Card |
605
(Unlock failure) |
1. Diskette Drive
2. Drive Cable
3. I/O Function Card |
662
(Diskette drive configuration error) |
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Function Card |
762
(Coprocessor configuration error) |
1. Run Configuration/Setup
2. Battery, see "Battery"
3. BSP Processor |
962
(Parallel port error) |
1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. I/O Function Card |
11XX
(System-board serial port 1 or 2 error) |
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. I/O Function Card |
1600
(The System Management Card is not functioning)
Do the following before replacing a FRU:
Remove the AC power to the system, wait 20 seconds; then, re-connect the AC power. Wait 30 seconds; then,
power-on the system. |
1. I/O Board Cable
2. System Management Card Cable
3. System Management Card
4. I/O Function Card
5. I/O Board |
1762
(Fixed Disk Configuration error) |
1. Fixed Disk Cables
2. Run Configuration/Setup
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. I/O Function Card |
178X
(Fixed Disk error) |
1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. I/O Function Card |
1962
(Drive does not contain a valid boot sector) |
1. Verify a bootable operating system is installed
2. Run Diagnostics
3. Hard Disk Drive Cable
4. I/O Function Card
5. Hard Disk Drive |
2400
(Video controller test failure) |
1. Video Adapter (if installed)
2. I/O Function Card |
2462
(Video memory configuration error) |
1. Video Adapter (if installed)
2. I/O Function Card |
5962
(IDE CD-ROM configuration error) |
1. Run Configuration
2. CD-ROM Drive Cable
3. CD-ROM Drive
4. Battery, see "Battery"
5. I/O Board |
8603
(Pointing Device Error) |
1. Pointing Device
2. I/O Function Card |
0001200
(Machine check architecture error) |
1. BSP Processor
2. Processor Board |
000120PX
(Processor cache error) |
1. Processor X
2. Processor Board |
00019501
(Processor 1 is not functioning) |
1. VRM 1A/1B
2. Processor 1
3. Processor Board |
00019502
(Processor 2 is not functioning) |
1. VRM 2A/2B
2. Processor 2
3. Processor Board |
00019503
(Processor 3 is not functioning) |
1. VRM 3A/3B
2. Processor 3
3. Processor Board |
00019504
(Processor 4 is not functioning) |
1. VRM 4A/4B
2. Processor 4
3. Processor Board |
00019701
(Processor 1 failed BIST) |
1. Processor 1
2. Processor Board
3. I/O Board |
00019702
(Processor 2 failed BIST) |
1. Processor 2
2. Processor Board
3. I/O Board |
00019703
(Processor 3 failed BIST) |
1. Processor 3
2. Processor Board
3. I/O Board |
00019704
(Processor 4 failed BIST) |
1. Processor 4
2. Processor Board
3. I/O Board |
00180000
(No more hardware interrupt available for PCI adapter) |
1. Run Configuration/Setup
2. Failing Adapter
3. I/O Function Card |
00180100
(No room for PCI option ROM)
Note
Adapters have too many ROMs. Reduce number of PCI
adapters or disable their ROMs. |
1. Run Configuration/Setup
2. Failing Adapter
3. I/O Function Card |
00180200
(No more I/O space available for PCI adapter) |
1. Run Configuration/Setup
2. Failing Adapter
3. I/O Function Card |
00180300
(No more memory (above 1MB for PCI adapter) |
1. Run Configuration/Setup
2. Failing Adapter |
00180400
(No more memory (below 1MB for PCI adapter) |
1. Run Configuration/Setup
2. Move the failing adapter to slot 11 or 12
3. Failing Adapter |
00180500
(PCI option ROM checksum error) |
1. Remove Failing PCI Card
2. I/O Board |
00180600
(PCI to PCI Bridge error) |
1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing Adapter
4. I/O Function Card |
00180700
(PCI device not responding) |
1. System Management Card Cable
2. System Management Card
3. I/O Function Card
4. I/O Board |
00180800
(Unsupported PCI device error) |
1. Remove Failing PCI Card
2. I/O Board |
01295085
(ECC checking hardware test error) |
1. Processor Board
2. BSP Processor
3. Run memory diagnostics |
I9990301
(Fixed boot sector error, no operating system installed) |
1. Run Configuration/Setup for correct startup
2. Verify operating system installed |
I9990305
(Fixed boot sector error, no operating system installed) |
1. Install operating system to hard disk drive. |