13.535 bytes

Service Hints & Tips

Document ID: MCGN-42EQXL

Netfinity 7000 M10 - POST Error Codes

Applicable to: World-Wide

POST Error Codes

In the following error codes, X can be any number or letter.

Error Code/Symptom

FRU/Action

062
(Three consecutive boot failures using the default configuration.)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card

101, 102
(System and processor error)

1. I/O Board
2. Processor Board

106
(Diskette controller error)

1. I/O Function Card
2. I/O Board

111
(Channel check error)

1. I/O Board

114
(Adapter read-only memory error)

1. Failing Adapter
2. Run Diagnostics

129
(Internal Cache error)

1. BSP Processor
2. Processor Board

151
(Real time clock error)

1. Run Diagnostics
2. Battery, see "Battery"
3. I/O Function Card

161
(Real time clock battery error)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card

162
(Device Configuration Error)
Important
Be sure to load the default settings and any additional desired settings; then, save the configuration.

1. Run Configuration/Setup
2. Battery, see "Battery"
3. Failing Device
4. I/O Board

163
(Real-Time Clock error)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card

164
(Memory configuration changed)

1. If error 289 is displayed, follow instruction on screen.
Verify failing FRU in system error log.
2. Run Configuration/Setup
3. Memory Card
4. Processor Board

173
(System CMOS checksum bad)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. I/O Function Card

175
(Hardware error)

1. I/O Board
2. Processor Board
3. System Management Card

176
(Computer cover or cable cover was removed without
a key being used)

1. Run Configuration/Setup
2. Intrusion (C2 Security) Cable
3. Front Panel
4. I/O Function Card

177, 178
(Security hardware error)

1. Run Configuration/Setup
2. System Management Card
3. Front Panel

184
(Power-on password corrupted)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. System Management Card

185
(Drive startup sequence information corrupted)

1. Run Configuration/Setup
2. System Management Card

186
(Security control logic error)

1. Run Configuration/Setup
2. System Management Card
3. Front Panel

187
(VPD serial number not set.)

1. Set serial number in Setup
2. System Management Card

188
(Bad EEPROM CRC #2)

1. Run Configuration/Setup
2. I/O Board

189
(An attempt was made to access the server with invalid passwords)

1. Run Configuration/Setup, enter the administrator
password

201
(Memory test error)

1. DIMM
2. Memory Board
3. Processor Board

229
(Cache error)

1. BSP Processor
2. Processor Board

262
(DRAM parity configuration error)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. Processor Board

289
(DIMM has been disabled by the user or system)

1. Follow the instructions on the screen. Verify the failing
FRU in the system error log.

301
(Keyboard or keyboard controller error)

1. Keyboard
2. I/O Function Card
3. I/O Board

303
(Keyboard controller error)

1. Keyboard
2. I/O Function Card
3. I/O Board

602
(Invalid diskette boot record)

1. Diskette
2. Cable
3. Diskette Drive

604
(Diskette drive error)

1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Function Card

605
(Unlock failure)

1. Diskette Drive
2. Drive Cable
3. I/O Function Card

662
(Diskette drive configuration error)

1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Function Card

762
(Coprocessor configuration error)

1. Run Configuration/Setup
2. Battery, see "Battery"
3. BSP Processor

962
(Parallel port error)

1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. I/O Function Card

11XX
(System-board serial port 1 or 2 error)

1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. I/O Function Card

1600
(The System Management Card is not functioning)
Do the following before replacing a FRU:
Remove the AC power to the system, wait 20 seconds; then, re-connect the AC power. Wait 30 seconds; then,
power-on the system.

1. I/O Board Cable
2. System Management Card Cable
3. System Management Card
4. I/O Function Card
5. I/O Board

1762
(Fixed Disk Configuration error)

1. Fixed Disk Cables
2. Run Configuration/Setup
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. I/O Function Card

178X
(Fixed Disk error)

1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Adapter
4. Fixed Disk Drive
5. I/O Function Card

1962
(Drive does not contain a valid boot sector)

1. Verify a bootable operating system is installed
2. Run Diagnostics
3. Hard Disk Drive Cable
4. I/O Function Card
5. Hard Disk Drive

2400
(Video controller test failure)

1. Video Adapter (if installed)
2. I/O Function Card

2462
(Video memory configuration error)

1. Video Adapter (if installed)
2. I/O Function Card

5962
(IDE CD-ROM configuration error)

1. Run Configuration
2. CD-ROM Drive Cable
3. CD-ROM Drive
4. Battery, see "Battery"
5. I/O Board

8603
(Pointing Device Error)

1. Pointing Device
2. I/O Function Card

0001200
(Machine check architecture error)

1. BSP Processor
2. Processor Board

000120PX
(Processor cache error)

1. Processor X
2. Processor Board

00019501
(Processor 1 is not functioning)

1. VRM 1A/1B
2. Processor 1
3. Processor Board

00019502
(Processor 2 is not functioning)

1. VRM 2A/2B
2. Processor 2
3. Processor Board

00019503
(Processor 3 is not functioning)

1. VRM 3A/3B
2. Processor 3
3. Processor Board

00019504
(Processor 4 is not functioning)

1. VRM 4A/4B
2. Processor 4
3. Processor Board

00019701
(Processor 1 failed BIST)

1. Processor 1
2. Processor Board
3. I/O Board

00019702
(Processor 2 failed BIST)

1. Processor 2
2. Processor Board
3. I/O Board

00019703
(Processor 3 failed BIST)

1. Processor 3
2. Processor Board
3. I/O Board

00019704
(Processor 4 failed BIST)

1. Processor 4
2. Processor Board
3. I/O Board

00180000
(No more hardware interrupt available for PCI adapter)

1. Run Configuration/Setup
2. Failing Adapter
3. I/O Function Card

00180100
(No room for PCI option ROM)
Note
Adapters have too many ROMs. Reduce number of PCI
adapters or disable their ROMs.

1. Run Configuration/Setup
2. Failing Adapter
3. I/O Function Card

00180200
(No more I/O space available for PCI adapter)

1. Run Configuration/Setup
2. Failing Adapter
3. I/O Function Card

00180300
(No more memory (above 1MB for PCI adapter)

1. Run Configuration/Setup
2. Failing Adapter

00180400
(No more memory (below 1MB for PCI adapter)

1. Run Configuration/Setup
2. Move the failing adapter to slot 11 or 12
3. Failing Adapter

00180500
(PCI option ROM checksum error)

1. Remove Failing PCI Card
2. I/O Board

00180600
(PCI to PCI Bridge error)

1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing Adapter
4. I/O Function Card

00180700
(PCI device not responding)

1. System Management Card Cable
2. System Management Card
3. I/O Function Card
4. I/O Board

00180800
(Unsupported PCI device error)

1. Remove Failing PCI Card
2. I/O Board

01295085
(ECC checking hardware test error)

1. Processor Board
2. BSP Processor
3. Run memory diagnostics

I9990301
(Fixed boot sector error, no operating system installed)

1. Run Configuration/Setup for correct startup
2. Verify operating system installed

I9990305
(Fixed boot sector error, no operating system installed)

1. Install operating system to hard disk drive.



Search Keywords

Document Category

Diagnostics

Date Created

20-11-98

Last Updated

09-02-99

Revision Date

18-01-2000

Brand

IBM PC Server

Product Family

Netfinity 7000 M10

Machine Type

8680

Model

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes