3.831 bytes

Service Hints & Tips

Document ID: GSMH-38KBKR

This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose.

Servers - Intermittent media errors on read / write optical drives

Applicable to: World-Wide

Symptom:
Intermittent media errors on R/W optical drives.
Advanced diagnostics generate error 0217xxxx.

Problem Isolation Aids:
None

Fix:
1. Clean the optics. Refer to the following tip (Retain Record H127072)
2. Verify that the media cartridge capacity matches drive capacity:

FRU Number

Option Number(s)

Description

92F0167
66G7510

6450162,6451295
62G0489,62G2908,3432705

127MB R/W Optical Drive
127MB R/W Optical Drive

05H2005
05H3449

05H2784
05H2794,3432715

230MB R/W Optical Drive
230MB R/W Optical Drive



If a 230MB cartridge is used in a 127MB drive, intermittent errors will occur.
When replacing a failing R/W Optical Drive, be sure to order the correct size drive as the drives are similar in appearance.

For jumper/switch settings, Refer to the following tip (Retain Record H093531)

SAS KEYWORDS:
PSY2 9595POS 9595OPTIC D/T8595
8595 D/T9585 9585 D/T8639
8639 D/T8640 8640 D/T8641
8641 D/T8642 8642 D/T8650
8650 D/T9595 9595 300
310 320 500 520
720 704

Search Keywords

Hint Category

Optical Drives, Retain

Date Created

24-05-96

Last Updated

07-01-99

Revision Date

07-01-2002

Brand

IBM PC Server

Product Family

PC Server 300, PC Server 310, PC Server 320, PC Server 500, PC Server 520, PC Server 704, PC Server 720, Server 85, Server 95

Machine Type

8640, 8639, 8641, 8650, 8642, 9585, 9595, 8595

Model

TypeModel

Retain Tip (if applicable)

H003383

Reverse Doclinks
and Admin Purposes