IBM IntelliStation Z Pro - Fails to power on/off
Applicable to: World-Wide
Symptom:
The IntelliStation Z Pro 6899 systems may fail to power on or off using the external on/off button.
Problem isolation aids:
Cover alignment can affect operation of the on/off button. Verify all AC power connections and check AC input power to the system unit. Remove the cover and test the system operation. If the system can not be turned on and off with the cover removed this tip does not apply.
Fix:
Loosen the top two screws and re-align the top cover of the system. Before the screws are tightened, press the power button to see if the unit powers up. If so, the problem has been fixed and should not reoccur. The two top cover screws can be re-tightened.
SAS KEYWORDS:
PSVP PSY2 PSY2PWR PSVPPWR