2.178 bytes |
Service Hints & Tips |
Document ID: JBAR-3PTPYQ |
IBM PC730/PC750 - OS/2 "Sys 1202" error after reinstalling QAPlus/2
Applicable to: World-Wide
Service Information:
A SYS 1202 error may be displayed during IPL of OS/2 WARP after reinstalling QAPlus/2 using the diskette created with the Diskette Factory application.
The SYS 1202 error, indicating that the QAPlus/2 Device Driver failed to install, occurs because the reinstallation process
inserted a duplicate line in the CONFIG.SYS file.
Edit the CONFIG.SYS file to remove the second occurrence of the following statement: C: QAPLUS2 QAP2DRVR.SYS
QAPlus/2 is a trademark of DiagSoft, Inc
SAS KEYWORDS:
PSY2 D/T68XX 6887 6877
IBMPC PSVP PSVPDIAG PSY2DIAG
D/T6887 PSVPPROG PSY2PROG PSVPERR
PC 750 PC750 PC700 PC 730
PSY2ERR PC730 42206
|
Search Keywords |
| |
|
Hint Category |
Diagnostics, Retain, OS/2 | |
|