3.323 bytes |
Product Information |
Document ID: DDSE-42TPG9 |
Netfinity 3500 - Specifications
Applicable to: World-Wide
Size
Depth: 445 mm (17.5 in.)
Width: 200 mm (7.9 in.)
Height: 492 mm (19.4 in.)
Weight
Maximum configuration (as shipped): 17.3 kg (38 lb)
Standard configuration (as shipped): 15 kg (33 lb)
Environment
Air temperature:
System on: 10› to 35›C (50› to 95›F) at altitude 0 915 m (3000 ft)
10› to 32›C (50› to 90›F) at altitude 915 2134 m
(3000 7000 ft)
System off: 10› to 43›C (50› to 110›F)
Humidity:
System on: 8% to 80%
System off: 8% to 80%
Heat Output
Approximate heat output in British thermal units (BTU) per hour:
Maximum configuration (as shipped): 306 BTU/hour (90 watts)
Maximum configuration (theoretical)1 : 1564 BTU/hour (460 watts)
Electrical Input
Sine-wave input (50/60 Hz) is required
Input voltage:
Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
Input kilovolt-amperes (kVA) (approximately):
- Maximum (configuration as shipped): 0.70 kVA
Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
Acoustical Noise-Emission Values
Average sound-pressure levels:
At operator position:
- 42 dBA idle
- 46 dBA operating
At bystander position 1 meter (3.3 ft):
- 36 dBA idle
- 40 dBA operating
Declared (upper limit) sound power levels:
5.1 bels idle
5.5 bels operating
Note |
__________________________________________________________________________________________
1 Under typical maximum configurations, the heat output will be substantially below the theoretical maximum.
Search Keywords |
| |
Document Category |
Technical Specifications | |
Date Created |
03-12-98 | |
Last Updated |
03-12-98 | |
Revision Date |
03-12-99 | |
Brand |
IBM PC Server | |
Product Family |
Netfinity 3500 | |
Machine Type |
8644 | |
Model |
ALL | |
TypeModel |
| |
Retain Tip (if applicable) |
| |
Reverse Doclinks |