Error Symptoms

Error Symptom

FRU/Action

CD is not working properly.

1. Clean the CD
2. Clean the optical-head lens.
3. CD-ROM Drive

CD-ROM drive tray is not working.
(The server must be powered-on.)
If the server is on and the tray does not eject,

1. Insert the end of a paper clip into the
manual tray-release opening.
2. CD-ROM Drive

CD-ROM drive is not recognized.

1. Run Configuration/Setup, enabled primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.

Diskette drive in-use light stays on,
or the system bypasses the diskette drive.

If there is a diskette in the drive, verify that:
1. The diskette drive is enabled in the configuration
programs.
2. The diskette is good and not damaged.
(Try another diskette if you have one.)
3. The diskette is inserted correctly in the drive.
4. The diskette contains the necessary files to
start the server.
5. The software program is OK.

If the diskette drive in-use light stays on, or the system
continues to bypass the diskette drive, replace the
diskette drive.

Monitor problems (general)
Some IBM monitors have their own self-tests.
If you suspect a problem with your monitor,
refer to the information that comes with the monitor
for adjusting and testing instructions.

1. Monitor
2. Display Adapter/System Board



Search Keywords

Document Category

Diagnostics

Date Created

15-12-98

Last Updated

15-12-98

Revision Date

15-12-99

Brand

IBM PC Server

Product Family

Netfinity 5500 M10

Machine Type

8661

Model

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes