2.419 bytes

Service Hints & Tips

Document ID: MCGN-44PJBG

Netfinity 7000 M10 - On/Off switch cable detect not working

Applicable to: World-Wide

Source: RETAIN tip H165796

Abstract: ON/OFF switch cable detect not working.

SYMPTOM:
The system may not respond to ON/OFF, RESET, SCROLL or ENTER switches on the front panel and the system will NOT display any error. There are no cable detect codes installed in system.

PROBLEM ISOLATION AIDS:


FIX:
No permanent fix available.

WORKAROUND:
If system control buttons, ON/OFF, RESET, SCROLL and ENTER are not working, lift the top cover of the system and make sure the ends of all of the above switches are connected to the back of the front panel through a set of cables. Make sure that this cable is seated firmly to the back of the front panel. If cables are attached and buttons still do not function, turn system off by removing AC chord and replugging AC, then restart.

SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED

Search Keywords

PSY2, D/T8680, NETFINITY, UNCLASSIFIED

Document Category

Retain

Date Created

01-02-99

Last Updated

01-02-99

Revision Date

Brand

IBM PC Server

Product Family

Netfinity 7000 M10

Machine Type

8680

Model

TypeModel

Retain Tip (if applicable)

H165796

Reverse Doclinks
and Admin Purposes

Date last altered: A98/10/21