SYMPTOM:
Running PC Doctor Diagnostics on a server configured with any supported tape drive results in either of the following:

1. Without a tape cartridge in the tape drive, the diagnostics program does not test the device.
2. With a tape cartridge in the tape drive, the diagnostics program responds with the following test failure, then the Utility hangs:

" IDx LUNy, DEVICE NOT TESTED, CODE 8000H"

(where x = the SCSI ID, and y = the Logical Unit Number of the tape drive).


PROBLEM ISOLATION AIDS:
- The system is any Netfinity server properly configured with any supported tape drive.
- PC Doctor version 1.9.387 or below is used.

FIX:
A diagnostics test module for tape drives will be provided in a future version release of PC Doctor.

WORKAROUND:
Remove the media cartridge from the tape drive prior to running the PC Doctor Diagnostics Utility to avoid a program hang.

DETAIL:
PC Doctor version 1.9.387 (or below) does not incorporate a test module for tape drives.

This TIP will be Updated when PC Doctor includes the test module for tape drives.

PC Doctor is a trademark of Watergate Software, Inc.

SAS KEYWORDS:
PSY2, PSY2DIAGS, DIAGS, PC DOCTOR, D/T8651, D/T8644, HANG, ERROR, UNCLASSIFIED

Search Keywords

PSY2, PSY2DIAGS, DIAGS, PC DOCTOR, D/T8651, D/T8644, HANG, ERROR, UNCLASSIFIED

Hint Category

Retain

Date Created

29-04-98

Last Updated

30-04-98

Revision Date

29-04-99

Brand

IBM PC Server

Product Family

Netfinity 3500, Netfinity 7000

Machine Type

8644, 8651

Model

Various

TypeModel

Retain Tip (if applicable)

H163496

Reverse Doclinks
and Admin Purposes

Date last altered: A98/04/28, Owning B.U.: USA, USA=A, EMA=N, AFE=A