5.436 bytes

Product Information

Document ID: MCGN-46ARXW

Netfinity EXP10 - Symptom-to-FRU Index

Applicable to: World-Wide

Source: Hardware Maintenance Manual

Use the troubleshooting chart in this section to find solutions to problems that have definite symptoms.

Problem Indicator

FRU/Action

Amber LED on

Drive
Fan
Check ambient air temperature
ESM board
Power to server but not expansion unit
Power to expansion unit but not server
Clustering problems
Loose cable connections between expansion unit and server
External SCSI cable length too long for application
Adapter speed set too fast for external SCSI cable length
Note: For more information on SCSI issues, see the SCSI Adapter User's Guide.

Amber LED on, green LED off

Power Switch

Amber and green LEDs on

Power Supply

Amber and green LEDs off

Reseat drive CRU
Drive

All green LEDs off

Check AC voltage cabinet AC voltage line inputs.
Power Supplies
Mid-plane board

Intermittent power loss to
Expansion Unit

Check AC voltage line inputs, and cabinet power components.
Power Supplies
Mid-plane board

One or more green LEDs off

Reseat Power Supplies
Reseat drive CRU
Power Supplies
Drive CRUs
Mid-plane board
ESM board
Check SCSI cables

Unable to access drives on
one or both SCSI buses

Check SCSI cables and connections
Check the drive SCSI ID settings. If drives are daisy-chained to same SCSI bus, option switches 1 and 2
must be set to different SCSI ID settings ESM board

Random errors

Mid-plane board


Note: If you cannot find the problem in the troubleshooting charts, test the entire system. See the server documentation for more detailed information on testing and diagnostic tools.

Search Keywords

Document Category

Diagnostics

Date Created

24-03-99

Last Updated

24-05-99

Revision Date

25-05-2000

Brand

IBM PC Server

Product Family

Rack/Storage Enclosures

Machine Type

3520

Model

All

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes