1.815 bytes |
Service Hints & Tips |
Document ID: YAST-3NKRCS |
IBM IntelliStation M Pro - (Type 6898) MicroSoft system certification test hangs system
Applicable to: World-Wide
Symptom:
The system hangs during the following MicroSoft System Certification tests:
- Port Class Dynamic Configuration
- Media Class Dynamic Configuration
- Net Class Dynamic Configuration
- Other Classes Dynamic Configuration
Problem isolation aids:
The mouse and keyboard may not respond either. The system must be powered off and restarted to recover. No report logs are created.
Fix:
Before running the tests, SCSI channel B must be disabled in the Windows 95 Device Manager.
To re-enable SCSI channel B after completing the tests, SCSI channel B must be removed, and then re-detected in the Windows 95 Device Manager.
SAS KEYWORDS:
PSY2 PSY2ERR PSY2OPER PSVP
PSVPERR PSVPOPER D/T6898 M/T6898
6898 78334 78334F_1 UNCLASSIFIED
Search Keywords |
| |
Hint Category |
Retain, SCSI | |
Date Created |
06-11-97 | |
Last Updated |
15-05-98 | |
Revision Date |
08-04-99 | |
Brand |
IBM IntelliStation | |
Product Family |
M Pro | |
Machine Type |
6898 | |
Model |
All | |
TypeModel |
| |
Retain Tip (if applicable) |
H161610 | |
Reverse Doclinks |