Netfinity 5500 M20 - ServeRAID Startup Messages

Applicable to: World-Wide

Source: Hardware Maintenance Manual

ServeRAID Startup Messages
During power-on self-test (POST), the ServeRAID adapter or controller compares the stored configuration information to the configuration that is actually present. If a discrepancy exists, one or more status messages appear after POST completes, but before the operating system loads.

Notes
1. When the ServeRAID adapter or controller requires your input, a list of function keys will appear below the message.
2. Where the Action information tells you to start the IBM ServeRAID configuration program, insert the IBM ServeRAID Configuration Utility Diskette or CD into the appropriate drive; then, restart the server. The Action information also provides general information about the message.
3. Where SID and ch appear in these messages, SID shows the SCSI ID for the device and ch shows the channel to which the device is attached.
4. Where m or n appears in these messages, a number will appear in the actual message.


The following is a list of messages associated with the ServeRAID subsystem.
-------------------------
Auto rearrange.
Explanation: Auto rearrange is enabled or disabled.
Action: This is an information message. No action is required.

-------------------------------------------------------
Following drives not responding (old state: new state: ch: SID)
Explanation: One or more drives did not respond to the ServeRAID controller. This may occur if configured drives are missing or are not ready.

Where:
old state is the configured state of the drive.
new state is the state that the ServeRAID adapter or controller will assign to the drive.
ch is the channel where the drive was located previously.
SID is the SCSI ID for where the drive was located previously.

Examples of the possible state changes include:

Online to Defunct

(ONL: DDD x: y)

Ready to Empty

(RDY: EMP x: y)

Standby to Empty

(SBY: EMP x: y)

Rebuild to Defunct

(RBL: DDD x: y)

Hot Spare to Defunct

(HSP: DHS x: y)

Standby Hot Spare to Defunct

(SHS: DHS x: y)


Action: Press one of the following keys:

F4 Retry. Press this key after correcting a problem. For example, press F4 after you turn on the external storage enclosure that contains the hard disk drive.
F5 Accept. Press this key to accept the new state that the ServeRAID adapter or controller will assign to the drive. For example, the ServeRAID adapter or controller will assign the drive a state of defunct (DDD) or empty (EMP).

You can also press F5 when you must remove a drive, RAID level-1 and RAID level-5 logical drives are present, and performance in a degraded mode is acceptable. The ServeRAID adapter or controller will assign the drive a state of defunct (DDD), but the server can complete startup. However, the array will remain in Critical mode and the potential for data loss will exist until you replace and rebuild the defunct drive. To prevent the loss of data, replace and rebuild the defunct drive in a timely manner.

Note:
A hard disk drive in the DDD state does not necessarily mean that you need to replace the drive. Before you replace the drive, ensure that:

1. All cables are connected properly to the backplane and to the hard disk drive. Also, ensure that all cables inside the server are connected properly.
2. The hot-swap drive trays are seated properly in the drive bay.
3. If you have not already attempted to rebuild the drive, try rebuilding it.

After you perform these steps, if the hard disk drive does not function properly, replace the drive.


F10 Continue. Press this key to continue without change to the configuration.

----------------------------------------------
Following new drives found (old state: new state: ch: SID)

Explanation: The ServeRAID adapter or controller detects a new drive that is not part of the current configuration.
Action: This is an information message. No action is required.
-- or --
Following new drives found: (host id: old ch: old SID > new ch: new SID)
Explanation: New controller installed in a configured server, or drives are imported. This message might be preceded by the previous two messages and the F5 and F6 key choices because the drives were not found in the configured location. Appears when the ServeRAID adapter or controller detects that the identifiers of the drives do not match the controller configuration information.

Where:
host id identifies the System Name where the ServeRAID adapter or controller resides.
old ch is the channel that matches the drive configuration information.
old SID is the SCSI ID that matches the drive configuration information.
new ch is the channel where the drive is now located.
new SID is the SCSI ID where the drive is now located.

For example, when drives are imported from a server with the System Name of My Machine: (My Machine: 1:6 > 1:10)

In this example, the message indicates that the drive from Channel 1, SCSI ID 6 is now located at Channel 1, SCSI ID 10. The drive might have been physically moved to a new drive bay.

Action: Press one of the following keys:

F4 Retry. Press this key after correcting the problem. For example, press F4 after you move the hard disk drive to its previously assigned location, or after you
install the original hard disk drives back in the server.

F5 Accept. Press this key to accept the new state that the ServeRAID adapter or controller will assign to the drive. For example, the ServeRAID adapter or
controller will assign the drive a state of defunct (DDD) or empty (EMP).

Note
A hard disk drive in the defunct state does not necessarily mean that you need to replace the drive. Before you replace the drive, ensure that:
1. All cables are connected properly to the backplane or system board, and to the hard disk drive. Also, ensure that all cables inside the server are connected properly.
2. The hot-swap drive trays are seated properly in the drive bay.
3. If you have not already attempted to rebuild the drive, try rebuilding it.

After you perform these steps, if the hard disk drive does not function properly, replace the drive.


F6 Modify. This choice is not always active. Press this key to modify the configuration to match the current drive location. You might remove the hot-swap drives from the server for security or maintenance reasons. If you replace the drives but install them in different drive bays, you can press F6 to accept the new locations,
and the ServeRAID adapter or controller will update the configuration.

F7 Import. Press this key to import the configuration information from the drive and to update the configuration information for the ServeRAID adapter or controller. This choice is useful when you replace the ServeRAID adapter or controller in an existing ServeRAID subsystem.

You also might press F7 if you replace a whole set of drives with drives that were configured in another server with a ServeRAID adapter or controller.

Note
When you install drives in a server that has no logical drives defined, the F7 choice will not appear. The ServeRAID adapter or controller does not contain any logical drives in its factory configuration. Therefore, F7 will not appear. In this case, do the following:
1. Restart the server and press Ctrl+I to enter the Mini-Configuration program.
2. Select Advanced Functions.
3. Select Import Configuration from Drives to Controller and follow the instructions on the screen.


-----------------------------------------------------------------------------------------------------------------------------
Controller is not responding to commands. No logical drives are installed.
Explanation: The ServeRAID adapter or controller is not operational.
Action: Reseat the controller. If problem persists, replace the ServeRAID controller.

-------------------------------------------------------------
Error: Cannot disable this controller BIOS.
Explanation: The ServeRAID adapter or controller was unable to prevent an extra copy of its BIOS code from being stored on the server. This condition occurs when the server contains multiple ServeRAID controllers or controllers.
Action: This is an information message. No action is required.

-----------------------------------------------------------------
Following drives found in new location (old ch: old SID: > new ch: new SID)
Explanation: Configured drives are not in the configured location. This message will be preceded by the previous messages and the F5 key choice because configured drives were not found in the configured location. Appears when the ServeRAID adapter or controller detects that a previously configured drive is present, but the drive is in a new location.

Where:
old ch is the channel that matches the existing drive configuration information.
old SID is the SCSI ID that matches the existing drive configuration information.
new ch is the channel where the drive is now located.
new SID is the SCSI ID where the drive is now located.

For example:
(1 :5 > 1: 14)
In this example, the message indicates that the drive from Channel 1, SCSI ID 5 is now located at Channel 1, SCSI ID 14. The drive might have been physically moved to the new drive bay.

Action: Press one of the following keys:

F4

Retry. Press this key after correcting a problem. For example, press F4 after you move the hard disk drive to its previously assigned location.

F5

Accept. Press this key to accept the new state that the ServeRAID adapter or controller will assign to the drive. For example, the ServeRAID adapter or controller will assign the drive a state of defunct (DDD) or empty (EMP).

Note: A hard disk drive in the DDD state does not necessarily mean that you need to replace the drive.

Before you replace the drive, ensure that:
1. All cables are connected properly to the backplane and to the hard disk drive. Also, ensure that all cables inside the server are connected properly.
2. The hot-swap drive trays are seated properly in the drive bay.
3. If you have not already attempted to rebuild the drive, try rebuilding it.

After you perform these steps, if the hard disk drive does not function properly, replace the drive.

F6

Modify. Press this key to modify the configuration to match the current drive location.

You might remove the hot-swap drives from the server for security or maintenance reasons. If you replace the drives but install them in different drive bays, you can press F6 to accept the new locations, and the ServeRAID adapter or controller will update the configuration.


-----------------------------------
Installation stopped.
Explanation: The server cannot access the ServeRAID adapter or controller.
Action: This is a follow-on message to a preceding message. Follow the "Action" instructions for the preceding message to resolve the problem.

-------------------------------------------------
n logical drives are installed.
Explanation: n represents the number of defined logical drives.
Action: This is an information message. No action is required.

------------------------------------------------------------------------
NVRAM Cache Controller Not Responding
Explanation: BIOS code detected a bad or failed Battery-Backup.
Action: Press F9 to remove the Battery-Backup Cache controller from the configuration, or press F10 to exit without change.

-------------------------------------------------------------------
NVRAM Cache Controller Replacement
Explanation: The ServeRAID controller detects that the Battery-Backup Cache controller is defective.
Action: Press F8 if you replaced the Battery-Backup Cache controller, or press F10 if you have not replaced the Battery-Backup Cache controller.

-------------------------------------------------------
Recoverable configuration error
Explanation: The configuration data stored in NVRAM (Battery-Backup Cache) does not match the configuration data stored in the EEPROM.
Action:
1. Press Ctrl+Alt+Del to restart the system.
2. Press CTRL+I during POST to enter the Mini-Configuration program.
3. Select Advanced Functions from the Main Menu; then, select Import Configuration from Drive(s).

-----------------------------------------------------------------------------------------------------------------
WARNING: n logical drives are critical; n logical drives are offline.
Explanation: One or more hard disk drives have failed.
Action: Replace the defunct drives as soon as possible to prevent data loss.

------------------------------------------------------------------------------------------------
Your server has an error due to a Blocked Logical Drive.
Explanation: One or more logical drives are in a blocked state. A blocked logical drive cannot be accessed.
Action: Press F4 to unblock the logical drive, or press F5 to continue without unblocking.

------------------------------------------------------------------------
Unable to communicate with the controller
Explanation: The controller is not responding to commands.
Action: Reseat the controller. If the problem persists, replace the ServeRAID controller.

-----------------------------------------------------------------------------------
Controller Reg. <x> test failed. Test Number: <y>
Explanation: The controller or embedded controller failed the register test, where <x> is the register number and <y> is the test number.
Action: Reseat the controller. If the problem persists, replace the ServeRAID controller.

-------------------------------------------
Controller hardware error
Explanation: The controller is not responding to commands.
Action: Reseat the controller. If the problem persists, replace the ServeRAID controller.

------------------------------------------------------------------------------------------------
BIOS not loaded no devices found - Installation stopped.
Explanation: The BIOS is unable to find any logical drives attached to any ServeRAID controllers. Therefore the ServeRAID BIOS is not loaded.
Action: Reconnect the cable(s) attaching the hard drives to the controller and restart the system. If performing a service procedure, reconnect them when told to do so.

------------------------------------------------------------------------------------------------------------------
Controller Ok; Devices not responding check cables or enclosures.
Explanation: A SCSI connection problem has been detected.
Action: Check all cables and devices attached to the ServeRAID controller. Look for bent or missing pins on all cables and devices.

-----------------------------------------------------------------------------------------------------------------
Unable to communicate with the following devices. (Channel : SID)
Explanation: Devices at the channel and SCSI ID specified in the message are not responding. The devices may have been removed.
Action: Check that the device(s) are at the location specified. If they are located in an external enclosure, make sure that the external enclosure is powered on.

----------------------------------------------------------------------
Download codeblk (via bootblk) is ready.
Explanation: Preparations for the download of the firmware to the controller are complete.
Action: Insert the BIOS/Firmware Diskette and download the firmware. Restart the system.

-----------------------------------------------------------------------------------------------
Controller is not responding properly - Run Diagnostics.
Explanation: The controller is not responding appropriately to commands.
Action: Use the ServeRAID DOS Configuration Utility and run the diagnostics.

------------------------------------------------------------------------------------------------------------------------------------------
System PCI BIOS does not respond to commands; no logical drives are installed.
Explanation: The system's PCI BIOS is returning error status in response to calls to it.
Action: Refer to the system's HMM and run diagnostics.