3.217 bytes

Service Hints & Tips

Document ID: GSMH-3FBJFM

This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose.

PC Server 300 - EISA slot 6 configuration problem

Applicable to: World-Wide

Symptom:
EISA slot 6 can not be configured. When the configuration is viewed, it is seen as "OTHER". The other adapter slots are correctly shown as EISA slots.

Problem Isolation Aids:
a. The EISA Configuration diskette is version 1.00.
b. The system has a Pentium processor board installed.

Fix:
The following procedure will correct this problem:
1. Insert the EISA CONFIGURATION DISKETTE in the diskette drive
2. Type a DIR command (directory listing).
3. Look for a file named, "!MIC0005.CFG 7444 3-25-94 3:15PM".This is the Pentium system board configuration file.
4. Then, print out the file or use the "TYPE" command, either:
a. TYPE !MIC0005.CFG | MORE (for OS/2)
b. TYPE !MIC0005.CFG /P (for DOS).
This will allow you to view the text in the file. On the 1st page there is a list of the EISA slots, continued on page 2. If EISA slot 6 appears as follows:
SLOT(6) = OTHER(6)
LENGTH = 341
BUSMASTER = YES
It is incorrect.
5. Use an editor to correct the typographical error so slot.
6. Appears the same as the other EISA slots, as follows:
SLOT(6) = EISA(6)
LENGTH = 341
BUSMASTER = YES
The 486DX/2 system board uses the following file: "!MIC0004.CFG 5628 3-25-94 3:15PM". It is correct and may be used for a comparison.

Search Keywords

SAS KEYWORDS:
PSY2 PSY2PROG CONFIG 8640
SERVER 300 PCSERVER PC

Hint Category

Configuration, Retain

Date Created

24-07-95

Last Updated

25-03-99

Revision Date

25-03-2000

Brand

IBM PC Server

Product Family

PC Server 300

Machine Type

8640

Model

TypeModel

Retain Tip (if applicable)

H127122

Reverse Doclinks
and Admin Purposes