IBM PC730/PC750 - Video distortion with OS/2 Warp

Applicable to: World-Wide

Symptom:
Video distortion may occur on IBM PC 700 Series 6877 and 6887 systems running OS/2 WARP while moving a window with multiple windows open on the Desktop.

Problem Isolation Aids:
Open multiple windows on the Desktop. Move the windows around the screen. Video distortion of the windows may occur while moving the windows. The Matrox Millennium MGA video device drivers are installed. The video resolution is 640 X 480 X 256 colors.

Fix:
The failure has only been reported using the Matrox Millennium MGA video device drivers at 640 X 480 X 256 colors. Change the video resolution to 1024 X 768 or higher. There is no planned update for this problem at this time.