2.239 bytes

Service Hints & Tips

Document ID: MCGN-3ZXKD4

Netfinity 7000 M10 - Memory errors not in log if "all banks" memory test selected

Applicable to: World-Wide

Source: RETAIN tip H165150

Abstract:
Memory errors not in log if "all banks" memory test selected.

SYMPTOM:
Error not logged.

PROBLEM ISOLATION AIDS:
- The system is a Netfinity 7000 M10 server, Type 8680, any model.
- The system's diagnostics pass.
- The system is configured with PC Doctor version 21A.

FIX:
PC Doctor Diagnostic version 23A.

WORKAROUND:
Use diagnostic's log or SMI log to view.

DETAILS:
Test individual memory bank as indicated by screen or SMI error.

SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, DIAGNOSTIC, PC, DOCTOR, 103126, 21A, 23A, ERROR, LOG, 8680ERR

Search Keywords

PSY2, D/T8680, NETFINITY, UNCLASSIFIED, DIAGNOSTIC, PC, DOCTOR, 103126, 21A, 23A, ERROR, LOG, 8680ERR

Hint Category

Retain

Date Created

05-11-98

Last Updated

14-01-99

Revision Date

14-01-2000

Brand

IBM PC Server

Product Family

Netfinity 7000 M10

Machine Type

8680

Model

ALL

TypeModel

Retain Tip (if applicable)

H165150

Reverse Doclinks
and Admin Purposes

Date last altered: A98/11/02