35.434 bytes |
Service Hints & Tips |
Document ID: GSMH-3F5LY5 |
IBM PC/IBM IntelliStation - Numeric error codes
Applicable to: World-Wide
Numeric Error Codes:
In the following index, X can represent any number.
|
Error Code |
FRU/Action |
|
000 |
1. Verify adapter device and Bus Master fields are enabled in PCI configuration program. See documentation shipped with computer. |
|
02X |
1. SCSI Adapter |
|
08X |
1. SCSI Cable |
|
101 |
1. System Board |
|
102 |
1. System Board |
|
106 |
1. System Board |
|
110 |
1. Memory Module |
|
111 |
1. Reseat adapters |
|
114 |
1. Adapter Memory |
|
129 |
1. Processor |
|
151 |
1. System Board |
|
161 Bad CMOS battery. |
1. Run Setup |
|
162 |
1. Run Setup and verify Configuration |
|
162 |
1. Diskette Drive |
|
163 |
1. Time and Date Set? |
|
164 POST detected a base memory or extended memory size mismatch error. |
1. Run Setup. Check System Summary menu for memory size change. (See Setup Utility Program .) |
|
17X, 18X |
1. C2 Security |
|
175 |
1. Riser Card |
|
176 |
1. Covers were removed from the computer. |
|
177 |
1. Riser Card |
|
178 |
1. Riser Card |
|
183 |
1. Enter the administrator password |
|
184 |
1. Enter new password |
|
185 |
1. Set configuration and reinstall the boot sequence. |
|
186 |
1. Riser Card |
|
189 |
1. More than three password attempts were made to access the computer. |
|
1XX |
1. System Board |
|
201, 20X |
1. Memory Module |
|
225 |
1. Unsupported Memory |
|
229 |
1. L2 Cache Memory |
|
262 |
1. Run Setup. Check System Summary menu for memory type change. (See Setup Utility Program.) |
|
301 |
1. Keyboard |
|
303 |
1. Mouse |
|
303 |
1. Keyboard |
|
3XX Not listed above. |
1. Keyboard |
|
5XX |
1. Video Adapter |
|
601 |
1. Diskette Drive A |
|
602 |
1. Bad Diskette ? |
|
604 |
1. Run Setup and verify diskette configuration settings. |
|
604 |
1. Run Setup and verify diskette configuration settings |
|
605 |
1. Diskette Drive |
|
662 |
1. Diskette drive configuration error or wrong diskette drive type, run Set Configuration. |
|
6XX |
1. Diskette Drive |
|
762 |
1. Run Setup |
|
7XX |
1. Processor |
|
962 |
1. Run Configuration |
|
9XX |
1. Printer |
|
1047 |
1. 16-Bit AT Fast SCSI Adapter |
|
107X |
1. Check SCSI terminator installation. |
|
1101 |
1. Run Advanced Diagnostics |
|
1101, 1102, 1106, |
1. System Board |
|
1107 |
1. Communications Cable |
|
1102 |
1. Run Advanced Diagnostics |
|
1103 |
1. Run Advanced Diagnostics |
|
1106 |
1. Run Advanced Diagnostics |
|
1107 |
1. Serial Device Cable |
|
1110 Register test failed. |
1. Run Advanced Diagnostics |
|
1116 |
1. Run Advanced Diagnostics |
|
1117 |
1. Run Advanced Diagnostics |
|
1162 |
1. Run Configuration |
|
11XX |
1. System Board |
|
1201 |
1. System Board |
|
1202, 1206, 1208, |
1. Dual Async Adapter/A |
|
1207 |
1. Communications Cable |
|
13XX |
1. Game Adapter |
|
1402 |
Information only |
|
1403 |
Information only |
|
1404 System board timeout failure. |
1. Run Advanced Diagnostics |
|
1405 |
1. Run Advanced Diagnostics |
|
1406 |
1. Run Advanced Diagnostics |
|
14XX |
1. Printer |
|
15XX |
1. SDLC Adapter |
|
1692 |
1. Run FDISK to ensure at least one active partition is set active. |
|
16XX |
1. 36/38 Workstation Adapter |
|
1762 |
1. Run Configuration (See Setup Utility Program.) |
|
1780 (Disk Drive 0) |
1. See Power Supply. |
|
180X, 185X PCI configuration or resource error. |
1. Run Setup and verify PCI/ISA configuration settings. |
|
1962 |
1. Possible hard disk drive problem, see Hard Disk Drive Boot Error. |
|
209X |
1. Diskette Drive |
|
20XX |
1. BSC Adapter |
|
21XX |
1. SCSI Device |
|
2401, 2402 |
1. Display |
|
2401, 2402 |
1. System Board |
|
2409 |
1. Display |
|
2410 |
1. System Board |
|
2462 |
1. Check cable connections. |
|
3015, 3040 |
1. Network Attached? |
|
30XX |
1. PC Network Adapter |
|
3115, 3140 |
1. Network Attached? |
|
31XX |
1. Alternate PC Network Adapter |
|
36XX |
1. GPIB Adapter |
|
38XX |
1. DAC Adapter |
|
4611, 4630 |
1. Multiport/2 Interface Board |
|
4612, 4613 4640, 4641 |
1. Memory Module Package |
|
4650 |
1. Multiport Interface Cable |
|
46XX |
1. Multiport/2 Adapter |
|
5600 |
1. Financial System Controller Adapter |
|
5962 |
1. Run Configuration |
|
62XX |
1. 1st Store Loop Adapter |
|
63XX |
1. 2nd Store Loop Adapter |
|
64XX |
1. Network Adapter |
|
71XX |
1. Voice Adapter |
|
74XX |
1. Video Adapter |
|
76XX |
1. Page Printer Adapter |
|
78XX |
1. High Speed Adapter |
|
79XX |
1. 3117 Adapter |
|
80XX |
1. PCMCIA Adapter |
|
84XX |
1. Speech Adapter |
|
8601, 8602 |
1. Pointing Device |
|
8603, 8604 |
1. System Board |
|
86XX Not listed above |
1. Mouse |
|
89XX |
1. PC Music Adapter |
|
91XX |
1. Optical Drive |
|
96XX |
1. SCSI Adapter |
|
10101, 10102, 10104 |
1. Have customer verify correct operating system device drivers are installed and operational. |
|
10103, 10110, 101171 |
1. System Board |
|
10117 |
1. Check system |
|
10118 |
1. Run Diagnostics and verify the correct operation of the modem slot |
|
10119 |
1. Diagnostics detected a non-IBM modem |
|
10120 |
1. Check PSTN Cable |
|
10132, 10133, 10134 |
1. Modem |
|
10153 |
1. Data/Fax Modem |
|
101XX |
1. Modem Adapter/A |
|
10450, 10451, 10490 |
1. Run Advanced Diagnostics |
|
10452 |
1. Run Advanced Diagnostics |
|
10453 |
Information only |
|
10454 |
1. Run Advanced Diagnostics |
|
10455, 10456 |
1. Run Advanced Diagnostics |
|
10459 |
Information only |
|
10461 |
1. Run Advanced Diagnostics |
|
10462 |
1. Run Advanced Diagnostics |
|
10464 |
1. Run Advanced Diagnostics |
|
10467 |
1. Run Advanced Diagnostics |
|
10468 |
1. Run Advanced Diagnostics |
|
10469 |
1. Run Advanced Diagnostics |
|
10470, 10471, 10472 |
1. Run Advanced Diagnostics |
|
10473 |
Information only |
|
10480 |
1. Hard Disk Drive (ESDI) |
|
10481 |
1. Run Advanced Diagnostics |
|
10482 |
1. Run Advanced Diagnostics |
|
106X1 |
1. Check Configuration |
|
10635 |
1. Power-off computer, wait ten seconds; then power-on the computer. |
|
10651, 10660 |
1. Check Cables |
|
106XX |
1. Ethernet Adapter |
|
107XX |
1. 5.25-inch External |
|
109XX |
1. ActionMedia Adapter/A |
|
112XX |
1. SCSI Adapter |
|
119XX |
1. 3119 Adapter |
|
121XX |
1. Modem Adapter |
|
136XX |
1. ISDN Primary Rate Adapter |
|
137XX |
1. System Board |
|
141XX |
1. Realtime Interface Coprocessor Portmaster Adapter/A |
|
143XX |
1. Japanese Display Adapter |
|
14710, 14711 |
1. System Board |
|
148XX |
1. Video Adapter |
|
14901, 14902 |
1. Video Adapter |
|
14932 |
1. External Display |
|
16101 |
1. Riser Card Battey |
|
161XX |
1. FaxConcentrator Adapter |
|
164XX |
1. 120 MB Internal Tape Drive |
|
16500 |
1. 6157 Tape Attachment Adapter |
|
16520, 16540 |
1. 6157 Streaming Tape Drive |
|
166XX, 167XX |
1. Token Ring Adapter |
|
18001 to 18029 |
1. Wizard Adapter |
|
18031 to 18039 |
1. Wizard Adapter Cable |
|
185XX XX |
1. DBCS Japanese Display Adapter/A |
|
20001 to 20003 |
1. Image Adapter/A Image-I Adapter/A |
|
20004 |
1. Memory Module DRAM, VRAM |
|
20005 to 20010 |
1. Image Adapter/A |
|
200XX |
1. Image Adapter/A |
|
20101 to 20103 |
1. Printer/Scanner Option |
|
20104 |
1. Memory Module DRAM, VRAM |
|
20105 to 20110 |
1. Printer/Scanner Option |
|
Image Adapter/A Memory Test failure |
1. Replace memory module (shown in graphic.) |
|
206XX |
1. SCSI-2 Adapter |
|
208XX |
1. Any SCSI Device |
|
210XX XX 210XXX1 |
1. SCSI Hard Disk Drive |
|
Tape Drive amber LED remains on. |
1. Tape Drive |
|
Tape Drive green in use LED fails to come on. |
1. Tape Drive |
|
Tape automatically ejected from drive. |
1. Tape Cassette |
|
SCSI ID on rotary switch does not match SCSI ID set in configuration. Verify drive switches inside cover are set to zero. |
1. Rotary Switch Circuit Board |
|
Tape sticks/breaks in drive. Verify that the tapes used meet ANSI standard X3B5. |
1. Tape Cassette |
|
212XX |
1. SCSI Printer |
|
213XX |
1. SCSI Processor |
|
214XX |
1. WORM Drive |
|
215XX XC |
1. CD-ROM Drive I |
|
216XX |
1. Scanner |
|
217XX |
1. Rewritable Optical Drive |
|
218XX |
1. Changer |
|
219XX |
1. SCSI Communications Device |
|
24201 Y0, 24210 Y0 |
1. ISDN/2 Adapter |
|
273XX |
1. 1 Mbps Micro Channel Infrared LAN Adapter |
|
27501, 27503 |
1. ServerGuard Adapter |
|
27502, 27504, 27510 |
1. ServerGuard Adapter |
|
27509 |
1. Remove redundant adapters, run Auto Configuration program, then retest. |
|
27512 |
1. WMSELF.DGS diagnostics file missing. |
|
27535 |
1. 3V Lithium Backup Battery |
|
27554 |
1. Internal Temperature out of range |
|
27555, 27556 |
1. ServerGuard Adapter |
|
27557 |
1. 7.2V NiCad Main Battery Pack |
|
27558, 27559 |
1. PCMCIA Type II Modem |
|
27562 |
1. External Power Control not connected |
|
27563, 27564 |
1. External Power Control |
|
275XX |
1. Update Diagnostic Software |
|
27801 to 27879 |
1. Personal Dictation |
|
27880 to 27889 |
1. External FRU (Speaker, Microphone) |
|
I 99903 0X |
Possible hard disk drive problem, see Hard Disk Drive Boot Error |
|
Search Keywords |
| |
|
Hint Category |
Hardware Maintenance Information | |
|
Date Created |
13-03-97 | |
|
Last Updated |
15-06-98 | |
|
Revision Date |
08-06-99 | |
|
Brand |
IBM PC, IBM IntelliStation | |
|
Product Family |
PC 300GL, PC 300XL, PC 300PL, PC 330, PC 340, PC 350, PC 360, PC 365, PC 730, PC 750, M Pro, Z Pro, E Pro | |
|
Machine Type |
6272, 6275, 6282, 6285, 6284, 6561, 6591, 6588, 6562, 6592, 6862, 6892, 6571, 6573, 6575, 6576, 6577, 6560, 6581, 6583, 6585, 6586, 6587, 6598, 6589, 6875, 6876, 6877, 6885, 6886, 6887, 6888, 6889, 6898, 6899, 6893 | |
|
Model |
Various | |
|
TypeModel |
| |
|
Retain Tip (if applicable) |
N/A | |
|
Reverse Doclinks |