3.451 bytes |
Service Hints & Tips |
Document ID: DDSE-3U6LWY |
PC Server 320 / 500 / 520 / 720 - Multiple defunct fixed disks
Applicable to: World-Wide
Symptom:
Server 500/520 (8641) RAID array systems may be unable to start the fixed disk drives if multiple drives are DDD (defunct).
The following error message will be reported after selecting the "Replace" option in the RAID Option Diskette:
"Error in starting drive..."
Note:
If more than one drive appears defunct and the drives are not defective, data MAY NOT be lost. Restart each drive using the "REPLACE" option in the RAID Option Diskette and the procedure below. The "REPLACE" option will bring every drive back to an ONL state except the last drive in each array, which must be rebuilt.
Problem Isolation Aids:
None.
Fix:
Problem prevention:
To prevent multiple drives from appearing DDD, the DDD drive(s) should be disconnected from the backplane prior to rebooting the system.
The following procedure should be followed if multiple drives are DDD (defunct):
a. Physically disconnect ALL DEFUNCT DRIVES, except the one you are trying to start.
b. With the one defunct drive installed, select the "REPLACE" option in the REPLACE/REBUILD menu to start the drive.
c. Once started, you can insert the next defunct drive and start it.
d. Continue until all defunct drives have been started. The last drive of each array will report an OFL status. To bring the drive back to an ONL state, rebuild the drive using the "REBUILD" option in the RAID utility diskette.
SAS KEYWORDS:
PSY2 PSY2FDSK SERVER 520
RAID 8641 500 PSY2TBD
8640 D/T8640 8642 D/T8642
320 720 SCSI SCSI-2
Search Keywords |
| |
Hint Category |
Hard Drives, Retain | |
Date Created |
15-12-95 | |
Last Updated |
08-01-99 | |
Revision Date |
08-01-2001 | |
Brand |
IBM PC Server | |
Product Family |
PC Server 300, PC Server 320, PC Server 520, PC Server 720 | |
Machine Type |
8640, 8641, 8642 | |
Model |
Various | |
TypeModel |
| |
Retain Tip (if applicable) |
H131887 | |
Reverse Doclinks |