Specifications:

Size:
With pedestal:
- Depth: 635 mm (25 in.)
835 mm (32.8 in.) with cable cover
- Height: 635 mm (25 in.)
- Width: 247 mm (9.75 in.)

Weight:
- Minimum configuration as shipped: 29.1 kg (64 lb)

Environment:
Air temperature
- System on: 10 to 35C (50F to 95F)
Altitude: 0 to 914 mm (3000 ft.)
- System on: 10 to 32C (50F to 90F)
Altitude: 914m (3000 ft.) to 2133 m (7000 ft.)
- System off: 10C to 43C (50F 110 F)
Maximum Altitude: 2133 m (7000 ft.)
Humidity:
- System on: 8% to 80%
- System off: 8% to 80%
Maximum altitude: 2133 m (7000 ft.)

Heat Output:
Approximate heat output in British Thermal Units (BTU) per hour
- Minimum configuration: 150 BTU (44 watts)
- Maximum configuration: 3600 BTU (1055 watts)

Electrical Input:
- Sine-wave input (50 to 60 Hz is required)
Input voltage

- Low range
Minimum: 90 V ac
Maximum: 137 V ac

- High range
Minimum: 180 V ac
Maximum: 265 V ac

- Input kilovolt-amperes (kVA) approximately
Minimum configuration as shipped: 0.16 kVA
Maximum configuration: 1.0 kVA

Total Power Available for Drives:
- Nominal operating current allowed
+5 V dc line: 7.5 A base; 20.5 A with upgrade
+12 V dc line: 4.7 A base; 17.7 A with upgrade

Search Keywords

Hint Category

General Information, Hardware Maintenance Information

Date Created

07-10-96

Last Updated

15-07-98

Revision Date

14-07-99

Brand

IBM PC Server

Product Family

Rack/Storage Enclosures

Machine Type

3518

Model

ALL

TypeModel

Retain Tip (if applicable)

N/A

Reverse Doclinks
and Admin Purposes