21.127 bytes

Product Information

Document ID: DDSE-42TQWP

Servers - Announcement Letter: Clustering solutions and PC Server SCSI-2 F/W Enhanced Repeater

Applicable to: World-Wide

Your mission-critical business applications can now be installed on IBM PC Servers using the latest high-availability clustering hardware and software available in the PC marketplace. IBM, as part of an Early Adopter's Agreement with Microsoft's clustering initiative called Wolfpack, has hardware configurations certified under the Wolfpack platform. In addition, a PC Server Shared Disk Convenience Kit, PC Server SCSI-2 F/W Enhanced Repeater, and SmoothStart are being announced to facilitate installation of these configurations.

Certified Wolfpack hardware cluster configurations include:

-PC Server Enterprise Shared Disk Cluster - two PC Server 704 systems attached to single or multiple PC Server Enterprise Expansion Towers to form a software implemented RAID shared disk cluster

- PC Server Advanced Shared Disk Cluster - two PC Server 704 systems attached to single or multiple Symbios MetaStor expansion unit(**) to form a hardware implemented RAID shared disk cluster

- The PC Server Shared Disk Convenience Kit contains in one carton and under one ordering part number many of the necessary components to configure PC Servers and an PC Server Enterprise Expansion Tower for a shared disk solution. The PC Server SCSI-2 F/W Enhanced Repeater is a new repeater card option that now supports two repeater cards on one SCSI cus and twin tailing for high-availability cluster solutions. Rounding out these offerings is SmoothStart, the new IBM services that provide on-site installation of Wolfpack with performance and installation planning applications specifically designed for clustered configurations running under Wolfpack.

Product Number

Description Part Number

PC Server Shared Disk 94G7584
Convenience Kit

PC Server SCSI-2 F/W
Enhanced Repeater 94G7585

Ethernet Cluster Monitoring Cable #######

Description

The following IBM PC Server cluster configurations have been certified on the Wolfpack platform:

PC Server Enterprise Shared Disk Cluster

This two-node configuration consists of two PC Server 704 systems connected to a PC Server Enterprise Expansion Tower to provide a fault tolerant cluster solution using the software implemented RAID 5 function within Wolfpack. This cost-effective configuration provides very good data storage scalability as up to four PC Server Enterprise Expansion Towers can be supported to provide up to 324GB of data storage.

Each PC Server Enterprise Expansion Tower must be attached to an PC Server Ultra Wide SCSI PCI Adapter. If more than one PC Server Enterprise Expansion Tower is desired, additional PC Server Shared Disk Convenience Kits or individual elements of the kit, should be ordered to support each additional configuration. The configuration below provides the basic components to support a single PC Server Enterpirise Expansion Tower using twelve 4.51GB Wide Ultra SCSI Hot-Swap Hard Disk Drives. If configurations require 9.1GB hard drives an additional PC Server HS Backplane III and Backplane-to-backplane cable will be needed as these drives are half-high and only three drives can be installed in each hot-swap, six-bay backplane. Up to nine 9.1GB Wide Ultra SCSI Hot-Swap Hard Disk Drives can be supported and are certified in this PC Server Enterprise Expansion Tower configuration.

Improved high-availability in the PC Server Enterprise Expansion Tower can be obtained through installation of a PC Server 780W Redundant Power Option(94G4701). Customers choosing this option to initially upgrade a PC Server Enterprise Tower should order individual components of the PC Server Shared Disk Convenience Kit to avoid getting the 220 W PC Server Power Supply Upgrade which is not needed for PC Server Enterprise Expansion Tower using the PC Server 780W Redundant Power Option.

PC Server Enterprise Shared Disk Cluster Configuration:

Description Quantity Part Number

PC Server 704 2 86504M0 or 86505M0
PC Server 704 SMP 200MHz 2 94G6678
Processor Upgrade
PC Server 704 2.14GB Wide 2 94G7519
Ultra SCSI Hard Disk Drive
PC Server Ultra Wide SCSI 2 76H5407
PCI Adapter
PC Server Enterprise 1 3518001
Expansion Tower
PC Server 4.51GB Wide Ultra 12 94G7491
SCSI Hot-Swap HDD
or
PC Server 9.1GB Wide Ultra 9 94G7492
SCSI Hot-Swap HDD
PC Server Shared Disk 1 94G7584
Convenience Kit

PC Server Advanced Shared Disk Cluster

This two-node configuration also consists of two PC Server 704 systems, but they are connected to a high-performance, differential SCSI Symbios RAID subsystem. This configuraiton provides a hardware implemented RAID 5 solution for high-end cluster solutions. The Symbios MetaStor expansion unit is available in deskside enclosures. This configuration can be expanded to support up to four Symbios MetaStor expansion unit controllers in each PC Server connected to four deskside DS-20E and DS-10E enclosures for a total of 1080GB of data storage capacity. The Symbios enclosure features high-availability functions such as hot-swap redundant fans and power supplies, and hot-swap hard drives. In addition hot-swap redundant controllers are optionally available.

PC Server Advanced Shared Disk Cluster Configuration:

Description Quantity Part Number
PC Server 704 2 86504M0 or 86505M0
PC Server 704 SMP 200MHz 2 94G6678
Processor Upgrade
PS Server 704 2.14GB Side 2 94G7519
Ultra SCSI Hard Drive
Symbios Raid Controller 2 Reference only*
Symbios MetaStor(**) 1 Reference only*
DS-20E (Desk-side)
and/or
Symbios MetaStor 1 Reference only
DS-10E enclosure option
Symbios 9GB Hard Disk Drive 30 Reference only
and/or
4GB Hard Disk Drive

* These products are referenced as a part of this certified configuration. These products must be obtained through Symbios remarketers. Contact 800-###-#### in the US , or your local IBM marketing representative.

More information about today's clustering solutions and future certified configurations as they occur can be obtained on the Internet by entering:

http://www/pc.ibm.com/new/cluster.html

Information on Symbios products can be obtained on the Internet by entering:

http://www/symbios.com

PS Server Shared Disk Convenience Kit(94G7584)

The PC Server Shared Disk Convenience Kit is designed to provide many of the necessary components to upgrade an PC Server Enterprise Expansion Tower and a PC Server to support the PC Server Enterprise Shared Disk Cluster solution. The kit contains the following components:

Description Quantity Part Number
PC Server SCSI-2 F/W 2 94G7585
Enhanced Repeater
PS Server HS Backplane III 1 76H2670
Backplane-to-Backplane 2 94G4070
Cable
Expansion Enclosure Backplane 1 70G9876
Cable
PC Server Power Supply 1 70G9739
Upgrade
IBM 100/10 PCI Ethernet 2 25H4374
Adapter
External 3 Meter Cable 2 94G5567
Ethernet Cluster Monitoring 1 #######
Cable
PC Server 3518 Clustering 1 4307008
Configuration Guide

PC Server SCSI-2 F/W Enhanced Repeater(94G7585) The PC Server SCSI-2 F/W Enhanced Repeater increases the number of SCSI devices that can be installed on a single SCSI channel and now has high-availability function that allows two of these repeater cards to be attached the same SCSI bus through a SCSI host adapter installed in each server node. This provides the hardware link in case of failover to the shared disk sybsystem of PC Server Enterprise Shared Disk Cluster solution.

PC Server Ethernet Cluster Monitoring Cable(#######)

The PC Server Ethernet Cluster Monitoring Cable is a 25-foot cable that connects to each of the IBM 100/10 PCI Ethernet Adapters to provide a heart-beat monitoring capability between the two-node servers of the cluster configuration. Through this monitoring, Wolfpack provides a failover to the second node, if the first node experiences failure.

Cluster node status and monitoring is performed over both the production LAN and over the Ethernet to Ethernet through the PC Server Ethernet Cluster Monitoring Cable. Without using multiple cables or hub resources, this point to point cable allows reliable linkage between the two PC Server nodes in the cluster.

Technical Information

Energy Star Compliance

No

Note: The Energy Star emblem does not represent EPA endorsement of any product or service.

Performance Specifications

The PC Server SCSI-2 F/W Enhanced Repeater supports SCSI-2 Fast/Wide operation (20MB/s).

Physical Specifications

PC Server SCSI-2 F/W Enhanced Repeater:

- Approximate height: 107 mm (4.2 in)
- Approximate width: 175 mm (6.9 In)

Operating Environment

PC Server SCSI-2 F/W Enhanced Repeater:

- Temperature: 10 to 35 degrees C (50 to 95 degrees F) at 0 - 914m
(0-3000 ft.)
- Relative humidity: 8 to 80 percent

Agency Approvals

PC Server SCSI-2 F/W Enhanced Repeater

- Verified to comply with Part 15 of the FCC Rules for a Class A digital device
- CE Mark (EN 55022 Class A)
- CISPER 22, Class A
- IEC

Hardware Requirements

The PC Server Shared Disk Convenience Kit is supported in the PC Server Enterprise Shared Disk Cluster configuration listed in this announcement.

The PC Server SCSI-2 F/W Enhanced Repeater is supported in PC Server Enterprise Expansion Tower and PC Server 3519 Rack Storage Expansion Enclosure.

Description Machine Type Model Part Number

PC Server Enterprise 3518 001 3518001
Expansion Enclosure
PC Server 3519 Rack Storage 3519 001 3519001
Expansion Enclosure

Software Requirements: No unique software is required for either PC Server SCSI-2 F/W Enhanced Repeater or PC Server Shared Disk Convenience Kit. Wolfpack is required to support the configurations using these options listed in this announcement.

Compatibility When installed in the PC Server Enterprise Expansion Tower and PC Server 3519 Rack Storage Expansion Enclosure, the PC Server SCSI-2 F/W Enhanced Repeater is compatible with all options supported by these enclosures. The PC Server SCSI-2 F/W Enhanced Repeater is compatible with the following SCSI adapters:

Description Part Number Notes

IBM SCSI-2 Fast/Wide Adapter/A 70G8498 1,2,3
IBM SCSI-2 Fast/Wide Streaming 70G9263 1,2,3
RAID Adapter/A
PS Server SCSI-2 Fast/Wide PCI 94G3771 2,3,4
Adapter
PC Server SCSI-2 Fast/Wide PCI-Bus 94G2764 2,3,4
RAID Adapter
PC Server SCSI-2 Fast/Wide PCI 94G4673 2,3,4
Adapter II
PC Server Ultra Wide SCSI PCI 76H5407 2,3,4
Adapter
PC Server 704 SCSI-2 F/W PCI 94G5884 5
RAID Adapter
PC ServeRAID SCSI Adapter 70G8489 2,3,4

NOTE: All configurations may not be compatible. The adapters listed above require external SCSI Cables to attach to the PC Server SCSI-2 F/W Enhanced Repeater. The cables are identified below:

Description Part Number

(1) SCSI-2 Card to SCSI-2 Option Cable (1-meter) 06H3231
(2) PC Server 3.0M SCSI-2 F/W Cable * 94G5567
(3) PC Server 4.3M SCSI-2 F/W Rack Cable * 94G5566
(4) PC Server F/W to F/W External SCSI Cable 70G9857
(5) PC Server 8mm to 68-Pin HD SCSI Cable 94G6276

(*) When installing either of these cables on either SCSI adapters (70G8498) or (70G9263), a 68-pin SCSI-2 F/W converter (94G5569) is required between the cable and the external connector on the SCSI adapter.

Limitations

The PC Server SCSI-2 F/W Enhanced Repeater limitations include:

- This adapter supports SCSI-2 Fast/Wide mode. Ultra SCSI mode is not supported.

- A maximum of 12 Fast/Wide SCSI-2 hot-swap disk drives are supported on a single SCSI channel when attached to a PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter. A maximum of seven SCSI devices are supported on a single channel when attached to all other supported SCSI adapters.

- Daisy-chaining of backplanes within a PC Server Enterprise Expansion Tower is supported when attached to either the PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter configured as follows:

- Up to two backplanes when using slim-high, hot-swap hard disk drives
- Up to three backplanes when using slim-high, hot-swap hard disk drives

Daisy-chaining is supported on other SCSI adapters in the following configuration:

- Up to two backplanes when using half-high, hot-swap hard disk drives

Planning Information
Additional Cable Orders Required for the PC Server SCSI-2 F/W Enhanced Repeater:

Yes

The PC Server Enterprise Expansion Tower connects to one or more external SCSI-2 Fast/Wide connectors on the host system through an external cable that goes to the back of the enclosure. An internal cable brings the signal from the back of the enclosure to the backplane or media bays. When a PC Server SCSI-2 F/W Enhanced Repeater is installed in the PC Server Enterprise Expansion Tower, the external cable will instead attach to the external connector of the PC Server SCSI-2 F/W Enhanced Repeater and the internal cable will attach to the internal connector on the PC Server SCSI-2 F/W Enhanced Repeater. Any additional cabling configurations to support internal expansion of the PC Server Enterprise Expansion Tower remain unchanged from the PC Server Enterprise Expansion Tower announcement.

Approximate Installation Time: The PC Server Shared Disk Convenience Kit requires approximately one hour t install.

The PC Server SCSI-2 F/w Enhanced Repeater takes approximately 15 minutes to insatll.

Packaging: PC Server Shared Disk Convenience Kit (94G7584) is contained in one box. The following components are included:

Description Quantity
----------- --------
PC Server SCSI-2 F/W 2
Enhanced Repeater
PC Server HS Backplane III 1
Backplane-to-Backplane 2
Cable
Expansion Enclosure Backplane 1
Cable
PC Server Power Supply 1
Upgrade
IBM 100/10 PCI Ethernet 2
Adapter
External 3 Meter Cable 2
Ethernet Cluster Monitoring 1
Cable
PC Server 3518 Clustering 1
Configuration Guide

PC Server SCSI-2 F/w Enhanced Repeater (94G7585) in contained in one box. The following components are included:

Description Quantity
SCSI-2 Repeater Card 1
Installation Instructions 1

Publications

None

Security, Auditability, and Control

These products use the security and auditability features of the PC Server Enterprise Expansion Tower and PC Server 704 in which they are installed.

Search Keywords

Document Category

Technical Specifications

Date Created

03-12-98

Last Updated

21-01-99

Revision Date

21-01-2000

Brand

IBM PC Server

Product Family

Clustering, PC Server 704

Machine Type

Various, 8650

Model

ALL

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes