2.264 bytes

Service Hints & Tips

Document ID: RMIE-3E2FVQ

This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose.

IBM PC350 - Fails to power-on with 220V selected

Applicable to: World-Wide

Abstract :
PC 300 6586 Fails to Power on with 220V

Symptom :
IBM PC 300 Series 6586 systems may fail to power on if the power supply is set for 220 volts and connected to a 220 volt outlet.

Problem Isolation Aids :
The system may power on initially, however, after powering the system off and then back on using the On/Off switch on the system unit, the power supply will not function.

The power supply will function normally at 220 volts if the system is powered off by disconnecting the system from the 220v source, such as a power strip, surge suppressor or circuit breaker.

Affected power supplies are manufactured for IBM by Golden Systems Inc. and contain either of the following two bar code headers: B16M5
B182T

Fix :
Replace power supply FRU P/N 06H2968.


SAS Keywords :
PSVP PSY2 IBMPC PSY2PWR
PSVPPWR PC 350 53157

Search Keywords

Hint Category

Retain, Power

Date Created

06-02-97

Last Updated

27-04-98

Revision Date

23-04-99

Brand

IBM PC

Product Family

PC 350

Machine Type

6586

Model

Various

TypeModel

Retain Tip (if applicable)

H136483

Reverse Doclinks