IBM IntelliStation M Pro (Type 6898)/Netfinity3500 - SCSI BIOS error: "SCSI Termination Not Found" (US ONLY)

Applicable to: United States

SYMPTOM:
When booting the system, the SCSI BIOS returns the following, or similar error message:

"SCSI Termination Not Found"

The SCSI subsystem will not be enabled.

PROBLEM ISOLATION AIDS:
This tip applies to IBM IntelliStation M-Pro Series 6898 and Netfinity 3500 Series 8644 systems.

The "SCSI Termination Not Found" error message will manifest itself as an "out-of-box" error in new systems preconfigured for SCSI operation.

In systems preconfigured for IDE operation, the SCSI error message may not be seen until the on-board SCSI BIOS is enabled in the F1 Setup utility, and a SCSI hardfile is installed.

Planar FRU numbers exposed to this condition are P/N93H7269 and P/N08L0046 (for 333MHz Models).

FIX:
Follow normal problem determination steps to eliminate possible SCSI adapter, SCSI cable, or SCSI hardfile errors.

If the "SCSI Termination Not Found" error persists, replace the system board with the FRU P/N08L0606.

Note: When servicing Netfinity 3500, Type 8644-1xx/2xx systems, see Retain Tip number H106654 for instructions on planar replacement, and saving the CMOS configuration.

SAS KEYWORDS:
PSY2 PSY2ERR PWS PWSERR
D/T6898 6898 NETFINITY 3500 8644
UNCLASSIFIED 93H7269 08L0046

Search Keywords

Hint Category

Retain, SCSI

Date Created

02-06-98

Last Updated

18-06-98

Revision Date

16-06-99

Brand

IBM IntelliStation, IBM PC Server

Product Family

M Pro, Netfinity 3500

Machine Type

6898, 8644

Model

various

TypeModel

Retain Tip (if applicable)

H163815

Reverse Doclinks
and Admin Purposes