Service Hints & Tips

Document ID: MCGN-3VSQWX

Servers - OS/2 Trap Errors

Applicable to: World-Wide

The following information will be helpful in diagnosing trap errors.

Error Code

Information

0000
0001

See note 7
(Application software error, contact the software vendor's support).

0002

See notes 4, 6, 8, and 9. Install CSDs, run CHKDSK. Replace the
defective memory.

0003
0004
0005

See note 7
(Application software error, contact the software vendor's support).

0006
0007
0008

Check the memory. Run CHKDSK. Contact the application software
vendor's support.

0009
000A
000B

See note 7
(Application software error, contact the software vendor's support).

000C

If SYS1942 appears, contact the software vendor's support.
If Exception in Device... appears, refer to note 4. Run CHKDSK.
All other messages: Run CHKDSK and check the memory.
If a 113 error appears, see ECA024.

000D

If SYS1943 A Prog... appears, contact the software vendor's
support.
If Int Proc Error at 0220:3557 appears, set the Token Ring to 16K
RAM window, install CSD's.
If double trap 000D appears, install the latest CSDs.
For all other messages or conditions, contact the software vendor's support.

000E

See note 7
(Application software error, contact the software vendor's support).

0010

Hardware of software error. Run diagnostics to check math
coprocessor. If diagnostics find no problem, see note 7
(contact the software vendor's support).



Notes:
1. Memory intensive operating systems such as OS/2, AIX*, or UNIX based operating systems are capable of revealing highly intermittent errors not detected by diagnostics.

2. Highly intermittent errors might go undetected by diagnostics tests. If no error occurs during the test, multiple replacements of memory might be required to resolve the problem.

3. Install all software updates. This applies to applications and operating systems.

4. The enhanced memory adapter (FRU 34F2825) might experience Trap 0002 errors if it does not have diagonal resistors across U21-U24. See ECA042. (The enhanced memory adapter has been redesigned without resistors, so this note might not apply to the computer you are servicing.)

5. Intermittent errors can be caused by outside sources of static, noise, or power.

6. Trap 0002 can be caused by a memory or adapter failure. Read the message details. It might be the system board, system-board memory, or adapter.

7. Trap 000D errors are software errors. The customer should contact the software vendor for possible patches.

8. For 8570 systems, refer to ECA059, ECA051.

9. For 8580-AXX Models, see ECA051 for possible system board replacement to correct Trap 002, NMI, or DOS parity errors.

System Aid Diskette
A system aid diskette is now available for Trap 0002 errors. Dealers can download it from the Technical Advisors Bulletin Board as file TRAP2LOG. The diskette will read NVRAM and indicate which of four possible sources caused the error. The four possible errors and their causes are listed below.

Error Code

Information

110

Usually a system-board memory error. If replacing the memory
does not fix the problem, suspect the system board.

111

I/O Channel Check. Any adapter could cause this error, but usually
a memory adapter is the cause.

112

Watchdog Timeout. Could be hardware or software. If replacing
the system board does not fix the problem, suspect the software.

113

DMA Timeout. Usually a software error, but possibly a hardware
failure (system board). If it is a 70-A21 with a 113 error, see ECA056,
run CHKDSK. Contact the software vendor for more information.
If it is any other system with a 113 error, refer to ECA023.
Check the hardware.



Search Keywords

Hint Category

OS/2

Date Created

25-06-98

Last Updated

03-02-99

Revision Date

03-02-2000

Brand

IBM PC Server

Product Family

PC Server 300, PC Server 310, PC Server 320, PC Server 500, PC Server 520, PC Server 720, Rack/Storage Enclosures

Machine Type

8640, 8639, 8641, 8642, 3517, 3518

Model

Various

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes