33.725 bytes

Product Information

Document ID: MCGN-437RSR

Netfinity 5500 M10 - Diagnostic Error Codes

Applicable to: World-Wide

Diagnostic Error Codes

Attention
In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are:
000 The test passed.
195 The Esc key was pressed to abort the test.
197 This a warning error and may not indicate a hardware failure.

For all error codes, replace/follow the FRU/Action indicated.


Error Code/Symptom

FRU/Action

001-XXX-000
(Failed core tests)

1. System Board

005-XXX-000
(Failed Video test)

1. System Board
2. Processor Board

011-XXX-000
(Failed COM1 Serial Port test)

1. System Board

011-XXX-001
(Failed COM2 Serial Port test)

1. System Board

014-XXX-000
(Failed Parallel Port test)

1. System Board

015-XXX-001
(Failed USB test)

1. System Board

020-XXX-000
(Failed PCI Interface test)

1. Processor Board
2. System Board

020-XXX-001
(Failed Hot Swap Slot 1 PCI Latch test)

1. PCI Hot Swap Latch Assembly
2. System Board

020-XXX-002
(Failed Hot Swap Slot 2 PCI Latch test)

1. PCI Hot Swap Latch Assembly
2. System Board

020-XXX-003
(Failed Hot Swap Slot 3 PCI Latch test)

1. PCI Hot Swap Latch Assembly
2. System Board

020-XXX-004
(Failed Hot Swap Slot 4 PCI Latch test)

1. PCI Hot Swap Latch Assembly
2. System Board

030-XXX-000
(Failed Internal SCSI interface test)

1. System Board

035-XXX-000
(Failed System Board RAID test)

1. System Board

035-XXX-001
(Failed RAID test for Fixed Disk in bay 1, SCSI ID 0)

1. Fixed Disk 1 on SCSI Backplane attached to
the RAID controller on the system board

035-XXX-002
(Failed RAID test for Fixed Disk in bay 2 SCSI ID 1)

1. Fixed Disk 2 on SCSI Backplane attached to
the RAID controller on the system board

035-XXX-003
(Failed RAID test for Fixed Disk in bay 3, SCSI ID 2)

1. Fixed Disk 3 on SCSI Backplane attached to
the RAID controller on the system board

035-XXX-004
(Failed RAID test for Fixed Disk in bay 4, SCSI ID 3)

1. Fixed Disk 4 on SCSI Backplane attached to
the RAID controller on the system board

035-XXX-005
(Failed RAID test for Fixed Disk in bay 5, SCSI ID 4)

1. Fixed Disk 5 on SCSI Backplane attached to
the RAID controller on the system board

035-XXX-006
(Failed RAID test for Fixed Disk in bay 6, SCSI ID 5)

1. Fixed Disk 6 on SCSI Backplane attached to
the RAID controller on the system board

035-XXX-100
(Failed test for RAID adapter installed in PCI slot 1)

1. RAID Adapter in PCI slot 1

035-XXX-101
(Failed PCI Slot 1 RAID test)

1. Fixed Disk 1 attached to RAID adapter
installed in PCI slot 1

035-XXX-102
(Failed PCI Slot 1 RAID test)

1. Fixed Disk 2 attached to RAID adapter
installed in PCI slot 1

035-XXX-103
(Failed PCI Slot 1 RAID test)

1. Fixed Disk 3 attached to RAID adapter
installed in PCI slot 1

035-XXX-104
(Failed PCI Slot 1 RAID test)

1. Fixed Disk 4 attached to RAID adapter
installed in PCI slot 1

035-XXX-105
(Failed PCI Slot 1 RAID test)

1. Fixed Disk 5 attached to RAID adapter
installed in PCI slot 1

035-XXX-106
(Failed PCI Slot 1 RAID test)

1. Fixed Disk 6 attached to RAID adapter
installed in PCI slot 1

035-XXX-200
(Failed test for RAID adapter installed in PCI slot 2)

1. RAID Adapter in PCI slot 2

035-XXX-201
(Failed PCI Slot 2 RAID test)

1. Fixed Disk 1 attached to RAID adapter
installed in PCI slot 2

035-XXX-202
(Failed PCI Slot 2 RAID test)

1. Fixed Disk 2 attached to RAID adapter
installed in PCI slot 2

035-XXX-203
(Failed PCI Slot 2 RAID test)

1. Fixed Disk 3 attached to RAID adapter
installed in PCI slot 2

035-XXX-204
(Failed PCI Slot 2 RAID test)

1. Fixed Disk 4 attached to RAID adapter
installed in PCI slot 2

035-XXX-205
(Failed PCI Slot 2 RAID test)

1. Fixed Disk 5 attached to RAID adapter
installed in PCI slot 2

035-XXX-206
(Failed PCI Slot 2 RAID test)

1. Fixed Disk 6 attached to RAID adapter
installed in PCI slot 2

035-XXX-300
(Failed test for RAID adapter installed in PCI slot 3)

1. RAID Adapter in PCI slot 3

035-XXX-301
(Failed PCI Slot 3 RAID test)

1. Fixed Disk 1 attached to RAID adapter
installed in PCI slot 3

035-XXX-302
(Failed PCI Slot 3 RAID test)

1. Fixed Disk 2 attached to RAID adapter
installed in PCI slot 3

035-XXX-303
(Failed PCI Slot 3 RAID test)

1. Fixed Disk 3 attached to RAID adapter
installed in PCI slot 3

035-XXX-304
(Failed PCI Slot 3 RAID test)

1. Fixed Disk 4 attached to RAID adapter
installed in PCI slot 3

035-XXX-305
(Failed PCI Slot 3 RAID test)

1. Fixed Disk 5 attached to RAID adapter
installed in PCI slot 3

035-XXX-306
(Failed PCI Slot 3 RAID test)

1. Fixed Disk 6 attached to RAID adapter
installed in PCI slot 3

035-XXX-400
(Failed test for RAID adapter installed in PCI slot 4)

1. RAID Adapter in PCI slot 4

035-XXX-401
(Failed PCI Slot 4 RAID test)

1. Fixed Disk 1 attached to RAID adapter
installed in PCI slot 4

035-XXX-402
(Failed PCI Slot 4 RAID test)

1. Fixed Disk 2 attached to RAID adapter
installed in PCI slot 4

035-XXX-403
(Failed PCI Slot 4 RAID test)

1. Fixed Disk 3 attached to RAID adapter
installed in PCI slot 4

035-XXX-404
(Failed PCI Slot 4 RAID test)

1. Fixed Disk 4 attached to RAID adapter
installed in PCI slot 4

035-XXX-405
(Failed PCI Slot 4 RAID test)

1. Fixed Disk 5 attached to RAID adapter
installed in PCI slot 5

035-XXX-406
(Failed PCI Slot 4 RAID test)

1. Fixed Disk 6 attached to RAID adapter
installed in PCI slot 4

035-XXX-500
(Failed test for RAID adapter installed in PCI slot 5)

1. RAID Adapter in PCI slot 5

035-XXX-501
(Failed PCI Slot 5 RAID test)

1. Fixed Disk 1 attached to RAID adapter
installed in PCI slot 5

035-XXX-502
(Failed PCI Slot 5 RAID test)

1. Fixed Disk 2 attached to RAID adapter
installed in PCI slot 5

035-XXX-503
(Failed PCI Slot 5 RAID test)

1. Fixed Disk 3 attached to RAID adapter
installed in PCI slot 5

035-XXX-504
(Failed PCI Slot 5 RAID test)

1. Fixed Disk 4 attached to RAID adapter
installed in PCI slot 5

035-XXX-505
(Failed PCI Slot 5 RAID test)

1. Fixed Disk 5 attached to RAID adapter
installed in PCI slot 5

035-XXX-506
(Failed PCI Slot 5 RAID test)

1. Fixed Disk 6 attached to RAID adapter
installed in PCI slot 5

035-XXX-600
(Failed test for RAID adapter installed in PCI slot 6)

1. RAID Adapter in PCI slot 6

035-XXX-601
(Failed PCI Slot 6 RAID test)

1. Fixed Disk 1 attached to RAID adapter
installed in PCI slot 6

035-XXX-602
(Failed PCI Slot 6 RAID test)

1. Fixed Disk 2 attached to RAID adapter
installed in PCI slot 6

035-XXX-603
(Failed PCI Slot 6 RAID test)

1. Fixed Disk 3 attached to RAID adapter
installed in PCI slot 6

035-XXX-604
(Failed PCI Slot 6 RAID test)

1. Fixed Disk 4 attached to RAID adapter
installed in PCI slot 6

035-XXX-605
(Failed PCI Slot 6 RAID test)

1. Fixed Disk 5 attached to RAID adapter
installed in PCI slot 6

035-XXX-606
(Failed PCI Slot 6 RAID test)

1. Fixed Disk 6 attached to RAID adapter
installed in PCI slot 6

075-XXX-000
(Failed Power Supply test)

1. Power Supply

089-XXX-001
(Failed Microprocessor test)

1. VRM for Microprocessor
2. Microprocessor

089-XXX-002
(Failed Optional Microprocessor test)

1. VRM for Optional Microprocessor
2. Optional Microprocessor

165-XXX-000
(Failed System Board test)

1. System Board
2. Processor Board
3. Power Backplane
4. Hot-Swap Drive Backplane

180-XXX-001
(Failed Information Panel LED test)

1. Information LED Panel
2. Power-on Panel

180-XXX-002
(Failed Diagnostics LED Panel test)

1. Diagnostics LED Panel
2. Power-on Panel

180-XXX-003
(Failed System Board LED test)

1. System Board

180-XXX-004
(Failed Processor Board LED test)

1. Processor Board
2. System Board

180-XXX-005
(Failed SCSI Backplane LED test)

1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board

201-XXX-001
(Failed Memory test, see "Memory Settings")

1. DIMM Location J1

201-XXX-002
(Failed Memory test, see "Memory Settings" )

1. DIMM Location J2

201-XXX-003
(Failed Memory test, see "Memory Settings" )

1. DIMM Location J3

201-XXX-004
(Failed Memory test, see "Memory Settings" )

1. DIMM Location J4

201-XXX-999
(Multiple DIMM failure, see error text.)

1. See error text for failing DIMMs

202-XXX-001
(Failed System Cache test)

1. Microprocessor

202-XXX-002
(Failed System Cache test on Optional Microprocessor)

1. Optional Microprocessor

206-XXX-000
(Failed Diskette Drive test)

1. Diskette Drive cable
2. Diskette Drive

215-XXX-000
(Failed IDE test)

1. System Board

217-XXX-000
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive.

1. Fixed Disk 1

217-XXX-001
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive.

1. Fixed Disk 2

217-XXX-002
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive.

1. Fixed Disk 3

217-XXX-003
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive.

1. Fixed Disk 4

217-XXX-004
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive.

1. Fixed Disk 5

217-XXX-005
(Failed BIOS Fixed Disk test)
Note
If RAID is configured, the fixed disk number refers to the
logical drive.

1. Fixed Disk 6

301-XXX-000
(Failed Keyboard test)

1. Keyboard

405-XXX-000
(Failed Ethernet test)

1. System Board



Search Keywords

Document Category

Diagnostics

Date Created

15-12-98

Last Updated

25-05-99

Revision Date

26-05-2000

Brand

IBM PC Server

Product Family

Netfinity 5500 M10

Machine Type

8661

Model

All

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes