3.773 bytes

Service Hints & Tips

Document ID: DSHY-3PVTP7

TP Selectadock III - SymptomToFRU Index - UltraBay II Tray Related Symptoms

Applicable to: World-Wide


____________________________________ ___________________________________
| Symptom or Error | FRUs of the SelectaDock |
| | Sequence of Actions |
|____________________________________|___________________________________|
| The HDD or FDD on the UltraBay II | 1. Reseat the drive. |
| tray does not work correctly. | 2. Reseat the power cable and |
| | SCSI cable of the of the |
| | UltraBay II tray. (See |
| | "UltraBay II Tray" in |
| | topic 7.8.4.) |
| | 3. Check that: |
| | a. The drive works correctly |
| | if it is installed in the |
| | UltraBay or UltraBay II |
| | of the computer. |
| | b. The IDE connector of the |
| | UltraBay II tray is |
| | connected correctly. |
| | c. No more than two IDE |
| | devices are installed |
| | including a device in the |
| | device space bay. |
| | 4. Run the drive test. |
| | 5. Main card. |
|____________________________________|___________________________________|

Search Keywords

Hint Category

Hardware Maintenance Information

Date Created

05-12-97

Last Updated

28-08-98

Revision Date

21-08-99

Brand

IBM ThinkPad

Product Family

ThinkPad Docking Stations

Machine Type

3547

Model

003

TypeModel

Retain Tip (if applicable)

N/A

Reverse Doclinks