3.773 bytes |
Service Hints & Tips |
Document ID: DSHY-3PVTP7 |
TP Selectadock III - SymptomToFRU Index - UltraBay II Tray Related Symptoms
Applicable to: World-Wide
____________________________________ ___________________________________
| Symptom or Error | FRUs of the SelectaDock |
| | Sequence of Actions |
|____________________________________|___________________________________|
| The HDD or FDD on the UltraBay II | 1. Reseat the drive. |
| tray does not work correctly. | 2. Reseat the power cable and |
| | SCSI cable of the of the |
| | UltraBay II tray. (See |
| | "UltraBay II Tray" in |
| | topic 7.8.4.) |
| | 3. Check that: |
| | a. The drive works correctly |
| | if it is installed in the |
| | UltraBay or UltraBay II |
| | of the computer. |
| | b. The IDE connector of the |
| | UltraBay II tray is |
| | connected correctly. |
| | c. No more than two IDE |
| | devices are installed |
| | including a device in the |
| | device space bay. |
| | 4. Run the drive test. |
| | 5. Main card. |
|____________________________________|___________________________________|
Search Keywords |
| |
Hint Category |
Hardware Maintenance Information | |
Date Created |
05-12-97 | |
Last Updated |
28-08-98 | |
Revision Date |
21-08-99 | |
Brand |
IBM ThinkPad | |
Product Family |
ThinkPad Docking Stations | |
Machine Type |
3547 | |
Model |
003 | |
TypeModel |
| |
Retain Tip (if applicable) |
N/A | |
Reverse Doclinks |