2.390 bytes |
Service Hints & Tips |
Document ID: GSMH-389ES9 |
This document is provided to IBM and our Business Partners to help sell and/or service IBM products. It is not to be distributed beyond that audience or used for any other purpose. |
TP 701 - Setting Jumpers For IDE CD-ROM In TP Dock II
Applicable to: World-Wide
Symptom:
The OBI 4X Slim CD Rom for Dock 1 & 2 is the same drive that is used in the 760ED, but is mounted in an adapter kit that attaches to the IDE connector in Dock-2. It is configured as a Slave device by default, and for 75X, 76X, and 360 systems it will work fine without making any changes.
The 701, however, requires that any IDE device in Dock-2 be configured as a Master.
Problem Isolation Aid:
None
Solution:
Here are the settings to make the change on either type of drive. (You can tell them apart as one has jumpers and one has switches)
There are two versions of the Slim CD-ROM 4X
TEAC
Setting by Jumper
S0: S :TEST Mode(Do not use)
S0: O :Normal
S1: S S2: S :Single
S1: S S2: O :Master
S1: O S2: S :CSEL
S1: O S2: O :Slave
S=Short O=Open</B>
SANYO
Setting by Switch
S6: 1 :Master
S6: 0 :Slave
S5: 1 :(Sleep Disable)
S5: 0 :(Sleep Enable)
S4: 1 :CSEL use with S6=0
S4: 0 :CSEL not use
1=On 0=off