3.234 bytes

Service Hints & Tips

Document ID: SCOD-43DN86

Netfinity 5000 - ASM DIMM Information Display Error

Applicable to: World-Wide

Source: RETAIN tip H165545

Abstract:
NETFINITY'S ASM DIMM INFORMATION DISPLAY ERROR

SYMPTOM:
Connect to a Netfinity 5000 through Netfinity Manager.

Open the Netfinity Service Manager. Open the Advanced System Management Service. Open the Configuration Information window.

Open the Memory Information window.

Results:
Note that the DIMM information is shown in reverse order. For example, the information for physical DIMM slot 1 on the
Planar is displayed as DIMM 4 in the Memory Information window.

PROBLEM ISOLATION AIDS:
The system is a Netfinity 5000 server Type 8659, any Model.

FIX:
The fix is available by downloading the Advanced Systems Management Processor Firmware Update Diskette v1.01 (Build Level 38A), or later, which is available at the following URL:

http://www.pc.ibm.com/searchfiles.html

WORKAROUND:
Use Netfinity System Information Tools to get memory information.

SAS KEYWORDS:
PSY2, D/T8659, NETFINITY, UNCLASSIFIED, SERVICE, PROCESSOR, MEMORY, DIMM, SLOT, ADVANCED, SYSTEM, MANAGEMENT


Search Keywords

PSY2, D/T8659, NETFINITY, UNCLASSIFIED, SERVICE, PROCESSOR, MEMORY, DIMM, SLOT, ADVANCED, SYSTEM, MANAGEMENT

Hint Category

Retain

Date Created

21-12-98

Last Updated

14-01-99

Revision Date

14-01-2000

Brand

IBM PC Server

Product Family

Netfinity 5000

Machine Type

8659

Model

all

TypeModel

Retain Tip (if applicable)

H165545

Reverse Doclinks
and Admin Purposes

Date last altered: A98/12/28