2.064 bytes |
Service Hints & Tips |
Document ID: RMIE-3BCKMW |
PC Server 310 - Hangs with Intel Etherexpress Adapter
Applicable to: World-Wide
Abstract :
Server 310 hangs with Intel EtherExpress Adapter
Symptom :
Upon booting the Server 310 (8639) and after loading the Adaptec SCSI BIOS, the system hangs with the following error message: 110 F000:D81D
Problem Isolation Aids :
The Server is an 8639-0EV with an Intel EtherExpress PCI PRO/100 Smart Adapter (P/N PILA8485) AND an Adaptec UltraSCSI Adapter FRU p/n 60H7823.
Fix :
Move the Adaptec UltraSCSI Adapter to PCI slot 3 and install the Intel EtherExpress Adapter in PCI slot 1 or 2.
The PCI Hold Time on the EtherExpress Adapter is not within the PCI specification. Moving the adapter closer to the planar reduces the delay to the PCI bus.
SAS Keywords :
PSY2 PSY2ADPT PSY2ERROR PSY2COMM
TRAP TRAPS HANG PSY2BRD
PSY2OEM POEM OEM 60H7823
UNCLASSIFIED
Search Keywords |
| |
Hint Category |
Adapter Cards, Retain | |
Date Created |
12-11-96 | |
Last Updated |
14-07-98 | |
Revision Date |
13-07-99 | |
Brand |
IBM PC Server | |
Product Family |
PC Server 300 | |
Machine Type |
8639 | |
Model |
0EV | |
TypeModel |
| |
Retain Tip (if applicable) |
H121333 | |
Reverse Doclinks |