2.379 bytes

Parts Information

Document ID: MCGN-3ZNPFV

Netfinity 7000 M10 - Operational parameters

Applicable to: World-Wide

Source: Hardware Maintenance Manual

Operational Parameters: The Operational Parameters window shows the current values or status of many system components monitored by the system management subsystem.

Available values include:
- Power supply voltages (including +5 V ac, +12 V ac, -3.3 V ac, -12 V ac; Netfinity 7000 servers feature additional -5 V ac and Voltage Regulation Module [VRM] monitors).

- Current temperatures and threshold levels for system components such as far-end adapter, center adapter, microprocessors, I/O board, and DASD backplane.

Note
Monitored system components vary by system management subsystem.


- System state (including O/S started, O/S running, POST started, POST stopped (error detected), and system powered off/state unknown).

- System power status (on or off).

- Power on hours; the total number of hours that the system has been powered on. (This is a cumulative count of all powered-on hours, not a count of hours since the last system restart).