2.552 bytes

Service Hints & Tips

Document ID: MCGN-44BQ8P

Netfinity 7000 M10 - System shuts down when PCI card is removed or added

Applicable to: World-Wide

Source: RETAIN tip H165703

Abstract:
System shuts down when PCI Card is removed or added.

SYMPTOMS:
System shuts down when hot adding or removing a PCI Card, especially in slot 3 or 5.

PROBLEM ISOLATION AIDS:
- The system is a Netfinity 7000 M10 server, Type 8680, all Models.

- The system is configured with any PCI Card.

- The system is configured with a NOS that supports HOT Swap PCI.

WORKAROUND:
Remove the PCI card(s) by pulling directly upward and not at any angle.

DETAILS:
This problem presents itself because the metal bracket at the end of the card touches against a two-pin jumper on the I/O Backplane and shorts out the power supply if the card is pulled out at an angle. The system is not damaged by this short, but the power supply does remove all power until the short is removed (i.e., the bracket is no longer causing a short).
NOTE: This issue should not arise if the plastic cover is left in place on the planar as it is shipped from the factory.

SAS KEYWORDS:
PSY2, D/T8680, NETFINITY, UNCLASSIFIED, PCI, 8680ADPT, HOT, 107020, SWAP, SLOT5, 8680OPER, OPERATION, SLOT3, PLASTIC, COVER

Search Keywords

PSY2, D/T8680, NETFINITY, UNCLASSIFIED, PCI, 8680ADPT, HOT, 107020, SWAP, SLOT5, 8680OPER, OPERATION, SLOT3, PLASTIC, COVER

Document Category

Retain

Date Created

20-01-99

Last Updated

21-01-99

Revision Date

Brand

IBM PC Server

Product Family

Netfinity 7000 M10

Machine Type

8680

Model

TypeModel

Retain Tip (if applicable)

H165703

Reverse Doclinks
and Admin Purposes

Date last altered: A99/01/15